# ABS tester pump-test time limit (1992–1993)

Canonical URL: https://miatatorque.com/spec/abs-tester-pump-test-time-limit-1992/

Applicability: NA 1992–1993 (B6, ABS) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.

Confidence: fsm

Pump runs for 5 seconds maximum; answer the tester’s PUMPING? prompt within 5 seconds.

Always confirm against your factory manual. Match every restriction and follow all stages and procedure notes. Disputed claims must not be automatically resolved. The complete record below preserves every printed unit, source claim and procedure.

```json
{
  "id": "abs-tester-pump-test-time-limit-1992",
  "name": "ABS tester pump-test time limit (1992–1993)",
  "aliases": [],
  "applies_to": [
    {
      "gen": "NA",
      "years": [
        1992,
        1993
      ],
      "engines": [
        "B6"
      ],
      "abs": true,
      "note": "1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed."
    }
  ],
  "kind": "non-torque",
  "value_text": "Pump runs for 5 seconds maximum; answer the tester’s PUMPING? prompt within 5 seconds.",
  "procedure": {
    "notes": "Factory ABS tester stationary test 5C, following its complete connection/power-up and static test sequence. Connect with ignition OFF, using the specified adapter to the hydraulic-unit, diagnosis and controller harness connectors; do not drive with the tester connected. The ABS system test uses ignition ON with the engine stopped. At the pump-test prompt push either tester switch and listen for the motor. Respond to the PUMPING? prompt within five seconds; otherwise the pump shuts off and the tester returns to the start of test 5C. This is tester-controlled diagnostic run time, not permission to jumper the pump directly."
  },
  "confidence": "fsm",
  "sources": [
    {
      "source": "fsm-1992",
      "page": "P–36 / P–38 / P–41 (PDF pp.674,676,679)",
      "as_printed": "PUMP WILL RUN FOR 5 SECONDS MAXIMUM.\nYOU MUST RESPOND WITHIN\n5 SECONDS OR PUMP WILL SHUT\nOFF, AND TESTER RETURNS\nTO START OF “5C PUMP TEST”.",
      "verified_years": [
        1992,
        1992
      ],
      "document": {
        "id": "fsm-1992",
        "tier": 1,
        "title": "1992 Mazda MX-5 Miata Workshop Manual",
        "part_number": "1271-10-91G (9999-95-0428-92)",
        "covers": [
          {
            "gen": "NA",
            "years": [
              1992,
              1992
            ],
            "engines": [
              "B6"
            ]
          }
        ],
        "note": "Cover identifies model year 1992; the download folder name is not evidence for 1993."
      }
    }
  ],
  "jobs": [],
  "system": "brakes",
  "component": "release-validation-2026-11",
  "componentName": "Factory brake release validation",
  "sequence_diagrams": [],
  "url": "https://miatatorque.com/spec/abs-tester-pump-test-time-limit-1992/"
}
```