# ABS valve relay component continuity (1999–2000)

Canonical URL: https://miatatorque.com/spec/abs-valve-relay-component-continuity-1999/

Applicability: NB 1999–2000 (BP-4W, ABS) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.

Confidence: fsm

Unpowered: B–C continuity and A–D open. With 12 V to B and C grounded: A–D continuity.

Always confirm against your factory manual. Match every restriction and follow all stages and procedure notes. Disputed claims must not be automatically resolved. The complete record below preserves every printed unit, source claim and procedure.

```json
{
  "id": "abs-valve-relay-component-continuity-1999",
  "name": "ABS valve relay component continuity (1999–2000)",
  "aliases": [],
  "applies_to": [
    {
      "gen": "NB",
      "years": [
        1999,
        2000
      ],
      "engines": [
        "BP-4W"
      ],
      "abs": true,
      "note": "1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed."
    }
  ],
  "kind": "non-torque",
  "value_text": "Unpowered: B–C continuity and A–D open. With 12 V to B and C grounded: A–D continuity.",
  "procedure": {
    "notes": "Remove and isolate the original valve relay from the hydraulic-unit relay assembly using the full removal procedure. In the factory four-contact layout A is the upper contact, D lower, B left and C right; match the original relay layout and circuit before testing. With no applied power check the B/C coil path and open A/D switched contacts. Apply 12 V positive to B and ground C and verify A/D continuity. Replace the relay if incorrect. The valve and motor relays have different specified coil power polarity; do not exchange their power connections or confuse component contact letters with controller/hydraulic-unit connector letters."
  },
  "confidence": "fsm",
  "sources": [
    {
      "source": "fsm-1999",
      "page": "04–13–7–8 (PDF pp. 415–416)",
      "as_printed": "Using an ohmmeter, inspect for continuity of the\nrelay terminals.\nConnect to\nB+\nGround\nB\nC\nIf not as specified, replace the valve relay.",
      "verified_years": [
        1999,
        1999
      ],
      "document": {
        "id": "fsm-1999",
        "tier": 1,
        "title": "1999 Mazda MX-5 Miata Workshop Manual",
        "covers": [
          {
            "gen": "NB",
            "years": [
              1999,
              2000
            ],
            "engines": [
              "BP-4W"
            ]
          }
        ],
        "url": "https://www.mellens.net/mazda/Mazda-Miata-1999-2001.pdf"
      }
    }
  ],
  "jobs": [],
  "system": "brakes",
  "component": "release-validation-1999-2026-11",
  "componentName": "Factory brake inspections (1999)",
  "sequence_diagrams": [],
  "url": "https://miatatorque.com/spec/abs-valve-relay-component-continuity-1999/"
}
```