# A/C condenser outlet pipe fitting (1990–1991)

Canonical URL: https://miatatorque.com/spec/ac-condenser-outlet-fitting-1990/

Applicability: NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.

Confidence: fsm

7–14 ft·lb / 9.8–20 N·m

Always confirm against your factory manual. Match every restriction and follow all stages and procedure notes. Disputed claims must not be automatically resolved. The complete record below preserves every printed unit, source claim and procedure.

```json
{
  "id": "ac-condenser-outlet-fitting-1990",
  "name": "A/C condenser outlet pipe fitting (1990–1991)",
  "aliases": [],
  "applies_to": [
    {
      "gen": "NA",
      "years": [
        1990,
        1991
      ],
      "engines": [
        "B6"
      ],
      "note": "1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed."
    }
  ],
  "kind": "torque",
  "torque": {
    "nm": [
      9.8,
      20
    ],
    "kgfm": [
      1,
      2
    ],
    "ftlb": [
      7.2,
      14
    ]
  },
  "procedure": {
    "notes": "Upper condenser outlet pipe union leading to the receiver/drier, one of the location-1 fittings in the factory line drawing. The lower inlet is location 2 and uses a different torque. For the original factory R-12 system; converted systems are outside this specification. Recover refrigerant with suitable recovery equipment before opening the system. Immediately plug open fittings to keep moisture out. Apply clean compressor oil to the O-rings before reconnecting; keep oil off the fitting nuts. Evacuate, charge and leak-test after repair. "
  },
  "confidence": "fsm",
  "sources": [
    {
      "source": "fsm-1990",
      "page": "U–37 (PDF p.780)",
      "as_printed": "①\n9.8—20 N·m (1.0—2.0 m-kg, 7.2—14 ft-lb)",
      "verified_years": [
        1990,
        1990
      ],
      "torque": {
        "nm": [
          9.8,
          20
        ],
        "kgfm": [
          1,
          2
        ],
        "ftlb": [
          7.2,
          14
        ]
      },
      "document": {
        "id": "fsm-1990",
        "tier": 1,
        "title": "1990 Mazda MX-5 Miata Workshop Manual",
        "part_number": "1193-10-89C",
        "covers": [
          {
            "gen": "NA",
            "years": [
              1990,
              1990
            ],
            "engines": [
              "B6"
            ]
          }
        ],
        "url": "https://archive.org/details/1990-mazda-mx-5-miata-workshop-manual_202411"
      }
    },
    {
      "source": "fsm-1990",
      "page": "U–32 (PDF p.775)",
      "as_printed": "Immediately plug all open fittings to keep moisture out of the system.\nApply clean compressor oil to the O-rings before connecting the fittings.\nDo not apply compressor oil to the fitting nuts.",
      "verified_years": [
        1990,
        1990
      ],
      "document": {
        "id": "fsm-1990",
        "tier": 1,
        "title": "1990 Mazda MX-5 Miata Workshop Manual",
        "part_number": "1193-10-89C",
        "covers": [
          {
            "gen": "NA",
            "years": [
              1990,
              1990
            ],
            "engines": [
              "B6"
            ]
          }
        ],
        "url": "https://archive.org/details/1990-mazda-mx-5-miata-workshop-manual_202411"
      }
    }
  ],
  "jobs": [],
  "system": "hvac",
  "component": "release-validation-2026-11",
  "componentName": "Factory air conditioning pressure inspection (1990)",
  "sequence_diagrams": [],
  "url": "https://miatatorque.com/spec/ac-condenser-outlet-fitting-1990/"
}
```