# A/C condenser outlet pipe fitting (1992–1993)

Canonical URL: https://miatatorque.com/spec/ac-condenser-outlet-fitting-1992/

Applicability: NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.

Confidence: fsm

7–14 ft·lb / 9.8–20 N·m

Always confirm against your factory manual. Match every restriction and follow all stages and procedure notes. Disputed claims must not be automatically resolved. The complete record below preserves every printed unit, source claim and procedure.

```json
{
  "id": "ac-condenser-outlet-fitting-1992",
  "name": "A/C condenser outlet pipe fitting (1992–1993)",
  "aliases": [],
  "applies_to": [
    {
      "gen": "NA",
      "years": [
        1992,
        1993
      ],
      "engines": [
        "B6"
      ],
      "note": "1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed."
    }
  ],
  "kind": "torque",
  "torque": {
    "nm": [
      9.8,
      20
    ],
    "kgfm": [
      1,
      2
    ],
    "ftlb": [
      7.2,
      14
    ]
  },
  "procedure": {
    "notes": "For the upper condenser outlet pipe union leading to the receiver/drier. This is separate from the lower condenser inlet union coming from the compressor discharge hose, whose torque is different. Recover refrigerant using appropriate equipment before opening the original R-12 system. Plug open fittings immediately; oil the O-rings with clean compressor oil and keep the fitting nuts free of oil. Evacuate, charge and leak-test after assembly."
  },
  "confidence": "fsm",
  "sources": [
    {
      "source": "fsm-1992",
      "page": "U–39 (PDF p. 1031)",
      "as_printed": "9.8—20 (1.0—2.0, 7.2—14)\nN·m (m-kg, ft-lb)",
      "verified_years": [
        1992,
        1992
      ],
      "torque": {
        "nm": [
          9.8,
          20
        ],
        "kgfm": [
          1,
          2
        ],
        "ftlb": [
          7.2,
          14
        ]
      },
      "document": {
        "id": "fsm-1992",
        "tier": 1,
        "title": "1992 Mazda MX-5 Miata Workshop Manual",
        "part_number": "1271-10-91G (9999-95-0428-92)",
        "covers": [
          {
            "gen": "NA",
            "years": [
              1992,
              1992
            ],
            "engines": [
              "B6"
            ]
          }
        ],
        "note": "Cover identifies model year 1992; the download folder name is not evidence for 1993."
      }
    }
  ],
  "jobs": [],
  "system": "hvac",
  "component": "combined-audit-2026-10",
  "componentName": "Factory early HVAC service settings",
  "sequence_diagrams": [],
  "url": "https://miatatorque.com/spec/ac-condenser-outlet-fitting-1992/"
}
```