# A/C external cooling-unit outlet pipe fitting (1990–1991)

Canonical URL: https://miatatorque.com/spec/ac-cooling-unit-outlet-fitting-1990/

Applicability: NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.

Confidence: fsm

14–22 ft·lb / 20–29 N·m

Always confirm against your factory manual. Match every restriction and follow all stages and procedure notes. Disputed claims must not be automatically resolved. The complete record below preserves every printed unit, source claim and procedure.

```json
{
  "id": "ac-cooling-unit-outlet-fitting-1990",
  "name": "A/C external cooling-unit outlet pipe fitting (1990–1991)",
  "aliases": [],
  "applies_to": [
    {
      "gen": "NA",
      "years": [
        1990,
        1991
      ],
      "engines": [
        "B6"
      ],
      "note": "1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed."
    }
  ],
  "kind": "torque",
  "torque": {
    "nm": [
      20,
      29
    ],
    "kgfm": [
      2,
      3
    ],
    "ftlb": [
      14,
      22
    ]
  },
  "procedure": {
    "notes": "External large outlet pipe union at the evaporator cooling unit, separate from its inlet and the internal expansion-valve outlet. Position the cooling unit so its connections match the heater and blower units. For the original factory R-12 system; converted systems are outside this specification. Recover refrigerant with suitable recovery equipment before opening the system. Immediately plug open fittings to keep moisture out. Apply clean compressor oil to the O-rings before reconnecting; keep oil off the fitting nuts. Evacuate, charge and leak-test after repair. "
  },
  "confidence": "fsm",
  "sources": [
    {
      "source": "fsm-1990",
      "page": "U–32 (PDF p.775)",
      "as_printed": "Outlet pipe     : 20—29 N·m (2.0—3.0 m-kg, 14—22 ft-lb)",
      "verified_years": [
        1990,
        1990
      ],
      "torque": {
        "nm": [
          20,
          29
        ],
        "kgfm": [
          2,
          3
        ],
        "ftlb": [
          14,
          22
        ]
      },
      "document": {
        "id": "fsm-1990",
        "tier": 1,
        "title": "1990 Mazda MX-5 Miata Workshop Manual",
        "part_number": "1193-10-89C",
        "covers": [
          {
            "gen": "NA",
            "years": [
              1990,
              1990
            ],
            "engines": [
              "B6"
            ]
          }
        ],
        "url": "https://archive.org/details/1990-mazda-mx-5-miata-workshop-manual_202411"
      }
    },
    {
      "source": "fsm-1990",
      "page": "U–37 (PDF p.780)",
      "as_printed": "③\n20—29 N·m (2.0—3.0 m-kg, 14—22 ft-lb)",
      "verified_years": [
        1990,
        1990
      ],
      "torque": {
        "nm": [
          20,
          29
        ],
        "kgfm": [
          2,
          3
        ],
        "ftlb": [
          14,
          22
        ]
      },
      "document": {
        "id": "fsm-1990",
        "tier": 1,
        "title": "1990 Mazda MX-5 Miata Workshop Manual",
        "part_number": "1193-10-89C",
        "covers": [
          {
            "gen": "NA",
            "years": [
              1990,
              1990
            ],
            "engines": [
              "B6"
            ]
          }
        ],
        "url": "https://archive.org/details/1990-mazda-mx-5-miata-workshop-manual_202411"
      }
    }
  ],
  "jobs": [],
  "system": "hvac",
  "component": "release-validation-2026-11",
  "componentName": "Factory air conditioning pressure inspection (1990)",
  "sequence_diagrams": [],
  "url": "https://miatatorque.com/spec/ac-cooling-unit-outlet-fitting-1990/"
}
```