# A/C cooling-unit external outlet fitting (1992–1993)

Canonical URL: https://miatatorque.com/spec/ac-cooling-unit-outlet-fitting-1992/

Applicability: NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.

Confidence: fsm

14–22 ft·lb / 20–29 N·m

Always confirm against your factory manual. Match every restriction and follow all stages and procedure notes. Disputed claims must not be automatically resolved. The complete record below preserves every printed unit, source claim and procedure.

```json
{
  "id": "ac-cooling-unit-outlet-fitting-1992",
  "name": "A/C cooling-unit external outlet fitting (1992–1993)",
  "aliases": [],
  "applies_to": [
    {
      "gen": "NA",
      "years": [
        1992,
        1993
      ],
      "engines": [
        "B6"
      ],
      "note": "1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed."
    }
  ],
  "kind": "torque",
  "torque": {
    "nm": [
      20,
      29
    ],
    "kgfm": [
      2,
      3
    ],
    "ftlb": [
      14,
      22
    ]
  },
  "procedure": {
    "notes": "For the larger external outlet pipe union at the evaporator cooling-unit bulkhead connection. This is separate from the expansion valve outlet joint inside the housing. Original factory R-12 system only. Recover refrigerant with proper recovery equipment before opening the system. Immediately plug open fittings to keep moisture out. Apply clean compressor oil to the O-rings before reconnecting; keep fitting nuts free of oil. Evacuate, charge and leak-test after assembly."
  },
  "confidence": "fsm",
  "sources": [
    {
      "source": "fsm-1992",
      "page": "U–34 (PDF p. 1026)",
      "as_printed": "Outlet pipe : 20—29 N·m (2.0—3.0 m-kg, 14—22 ft-lb)",
      "verified_years": [
        1992,
        1992
      ],
      "torque": {
        "nm": [
          20,
          29
        ],
        "kgfm": [
          2,
          3
        ],
        "ftlb": [
          14,
          22
        ]
      },
      "document": {
        "id": "fsm-1992",
        "tier": 1,
        "title": "1992 Mazda MX-5 Miata Workshop Manual",
        "part_number": "1271-10-91G (9999-95-0428-92)",
        "covers": [
          {
            "gen": "NA",
            "years": [
              1992,
              1992
            ],
            "engines": [
              "B6"
            ]
          }
        ],
        "note": "Cover identifies model year 1992; the download folder name is not evidence for 1993."
      }
    },
    {
      "source": "fsm-1992",
      "page": "U–39 (PDF p. 1031)",
      "as_printed": "20—29 (2.0—3.0, 14—22)\nN·m (m-kg, ft-lb)",
      "verified_years": [
        1992,
        1992
      ],
      "torque": {
        "nm": [
          20,
          29
        ],
        "kgfm": [
          2,
          3
        ],
        "ftlb": [
          14,
          22
        ]
      },
      "document": {
        "id": "fsm-1992",
        "tier": 1,
        "title": "1992 Mazda MX-5 Miata Workshop Manual",
        "part_number": "1271-10-91G (9999-95-0428-92)",
        "covers": [
          {
            "gen": "NA",
            "years": [
              1992,
              1992
            ],
            "engines": [
              "B6"
            ]
          }
        ],
        "note": "Cover identifies model year 1992; the download folder name is not evidence for 1993."
      }
    }
  ],
  "jobs": [],
  "system": "hvac",
  "component": "release-validation-2026-11",
  "componentName": "Factory air conditioning pressure inspection (1990)",
  "sequence_diagrams": [],
  "url": "https://miatatorque.com/spec/ac-cooling-unit-outlet-fitting-1992/"
}
```
