# A/C internal expansion-valve outlet pipe fitting (1992–1993)

Canonical URL: https://miatatorque.com/spec/ac-expansion-valve-outlet-fitting-1992/

Applicability: NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.

Confidence: fsm

22–25 ft·lb / 29–34 N·m

Always confirm against your factory manual. Match every restriction and follow all stages and procedure notes. Disputed claims must not be automatically resolved. The complete record below preserves every printed unit, source claim and procedure.

```json
{
  "id": "ac-expansion-valve-outlet-fitting-1992",
  "name": "A/C internal expansion-valve outlet pipe fitting (1992–1993)",
  "aliases": [],
  "applies_to": [
    {
      "gen": "NA",
      "years": [
        1992,
        1993
      ],
      "engines": [
        "B6"
      ],
      "note": "1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed."
    }
  ],
  "kind": "torque",
  "torque": {
    "nm": [
      29,
      34
    ],
    "kgfm": [
      3,
      3.5
    ],
    "ftlb": [
      22,
      25
    ]
  },
  "procedure": {
    "notes": "For the expansion-valve outlet connection to the evaporator inside the removed cooling-unit casing. This is separate from the external cooling-unit outlet fitting. During valve replacement, release the sensing capillary tube from the outlet pipe before removing the valve. Recover refrigerant with proper recovery equipment before opening the original R-12 system. Immediately plug open fittings to keep moisture out. Apply clean compressor oil to the O-rings before reconnecting, and keep oil off the fitting nuts. Evacuate, charge and leak-test after repair."
  },
  "confidence": "fsm",
  "sources": [
    {
      "source": "fsm-1992",
      "page": "U–35 (PDF p. 1027)",
      "as_printed": "Outlet pipe:\n29—34 N·m (3.0—3.5 m-kg, 22—25 ft-lb)",
      "verified_years": [
        1992,
        1992
      ],
      "torque": {
        "nm": [
          29,
          34
        ],
        "kgfm": [
          3,
          3.5
        ],
        "ftlb": [
          22,
          25
        ]
      },
      "document": {
        "id": "fsm-1992",
        "tier": 1,
        "title": "1992 Mazda MX-5 Miata Workshop Manual",
        "part_number": "1271-10-91G (9999-95-0428-92)",
        "covers": [
          {
            "gen": "NA",
            "years": [
              1992,
              1992
            ],
            "engines": [
              "B6"
            ]
          }
        ],
        "note": "Cover identifies model year 1992; the download folder name is not evidence for 1993."
      }
    }
  ],
  "jobs": [],
  "system": "hvac",
  "component": "combined-audit-2026-10",
  "componentName": "Factory early HVAC service settings",
  "sequence_diagrams": [],
  "url": "https://miatatorque.com/spec/ac-expansion-valve-outlet-fitting-1992/"
}
```