# A/C insufficient-cooling pressure check at 2,000 rpm (1990–1993)

Canonical URL: https://miatatorque.com/spec/ac-insufficient-cooling-pressure-check-1992/

Applicability: NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.; NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.

Confidence: fsm

Insufficient-cooling diagnostic at 2,000 rpm and maximum cooling: low side 147–294 kPa (1.5–3.0 kg/cm², 21–43 psi); high side 1,177–1,619 kPa (12.0–16.5 kg/cm², 171–235 psi).

Always confirm against your factory manual. Match every restriction and follow all stages and procedure notes. Disputed claims must not be automatically resolved. The complete record below preserves every printed unit, source claim and procedure.

```json
{
  "id": "ac-insufficient-cooling-pressure-check-1992",
  "name": "A/C insufficient-cooling pressure check at 2,000 rpm (1990–1993)",
  "short_name": "A/C diagnostic pressures at 2,000 rpm",
  "aliases": [],
  "applies_to": [
    {
      "gen": "NA",
      "years": [
        1992,
        1993
      ],
      "engines": [
        "B6"
      ],
      "note": "1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed."
    },
    {
      "gen": "NA",
      "years": [
        1990,
        1991
      ],
      "engines": [
        "B6"
      ],
      "note": "1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed."
    }
  ],
  "kind": "non-torque",
  "value_text": "Insufficient-cooling diagnostic at 2,000 rpm and maximum cooling: low side 147–294 kPa (1.5–3.0 kg/cm², 21–43 psi); high side 1,177–1,619 kPa (12.0–16.5 kg/cm², 171–235 psi).",
  "procedure": {
    "notes": "For the original R-12 system, connect the proper A/C manifold gauge set with both manifold valves closed before running the engine. Measure the low and high sides separately at the stated speed and cooling setting. This diagnostic page specifies 2,000 rpm; the separate running-pressure inspection at U–33 specifies 1,500 rpm and remains a distinct record. Do not apply these values to an R-134a conversion or open manifold valves during the running check."
  },
  "confidence": "fsm",
  "sources": [
    {
      "source": "fsm-1992",
      "page": "U–12 (PDF p. 1004)",
      "as_printed": "Operate the engine at 2,000 rpm and set the air conditioner to maximum cooling.\nLow-pressure side:\n147—294 kPa (1.5—3.0 kg/cm², 21—43 psi)\nHigh-pressure side:\n1,177—1,619 kPa (12.0—16.5 kg/cm², 171—235 psi)",
      "verified_years": [
        1992,
        1992
      ],
      "document": {
        "id": "fsm-1992",
        "tier": 1,
        "title": "1992 Mazda MX-5 Miata Workshop Manual",
        "part_number": "1271-10-91G (9999-95-0428-92)",
        "covers": [
          {
            "gen": "NA",
            "years": [
              1992,
              1992
            ],
            "engines": [
              "B6"
            ]
          }
        ],
        "note": "Cover identifies model year 1992; the download folder name is not evidence for 1993."
      }
    },
    {
      "source": "fsm-1992",
      "page": "U–32 (PDF p. 1024)",
      "as_printed": "Verify that high- and low-pressure side valves of the manifold gauge set are closed.",
      "verified_years": [
        1992,
        1992
      ],
      "document": {
        "id": "fsm-1992",
        "tier": 1,
        "title": "1992 Mazda MX-5 Miata Workshop Manual",
        "part_number": "1271-10-91G (9999-95-0428-92)",
        "covers": [
          {
            "gen": "NA",
            "years": [
              1992,
              1992
            ],
            "engines": [
              "B6"
            ]
          }
        ],
        "note": "Cover identifies model year 1992; the download folder name is not evidence for 1993."
      }
    },
    {
      "source": "fsm-1990",
      "page": "U–12 (PDF p. 755)",
      "as_printed": "Operate the engine at 2,000 rpm and set the air conditioner to maximum cooling.\nLow-pressure side:\n147—294 kPa (1.5—3.0 kg/cm², 21—43 psi)\nHigh-pressure side:\n1,177—1,619 kPa (12.0—16.5 kg/cm², 171—235 psi)",
      "verified_years": [
        1990,
        1990
      ],
      "note": "Visually checked against the original 1990 factory page, including printed units and component/test context.",
      "document": {
        "id": "fsm-1990",
        "tier": 1,
        "title": "1990 Mazda MX-5 Miata Workshop Manual",
        "part_number": "1193-10-89C",
        "covers": [
          {
            "gen": "NA",
            "years": [
              1990,
              1990
            ],
            "engines": [
              "B6"
            ]
          }
        ],
        "url": "https://archive.org/details/1990-mazda-mx-5-miata-workshop-manual_202411"
      }
    }
  ],
  "jobs": [],
  "system": "hvac",
  "component": "combined-audit-2026-10",
  "componentName": "Factory early HVAC diagnostic and cable settings",
  "sequence_diagrams": [],
  "url": "https://miatatorque.com/spec/ac-insufficient-cooling-pressure-check-1992/"
}
```