# A/C receiver/drier inlet and outlet pipe fittings (1992–1993)

Canonical URL: https://miatatorque.com/spec/ac-receiver-drier-inlet-outlet-fittings-1992/

Applicability: NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.

Confidence: fsm

7–14 ft·lb / 9.8–20 N·m

Always confirm against your factory manual. Match every restriction and follow all stages and procedure notes. Disputed claims must not be automatically resolved. The complete record below preserves every printed unit, source claim and procedure.

```json
{
  "id": "ac-receiver-drier-inlet-outlet-fittings-1992",
  "name": "A/C receiver/drier inlet and outlet pipe fittings (1992–1993)",
  "aliases": [],
  "applies_to": [
    {
      "gen": "NA",
      "years": [
        1992,
        1993
      ],
      "engines": [
        "B6"
      ],
      "note": "1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed."
    }
  ],
  "kind": "torque",
  "torque": {
    "nm": [
      9.8,
      20
    ],
    "kgfm": [
      1,
      2
    ],
    "ftlb": [
      7.2,
      14
    ]
  },
  "procedure": {
    "notes": "For both refrigerant pipe unions at the original receiver/drier beside the condenser. This value is for the pipe fittings, separate from the drier mounting bracket, sight glass and pressure switch. Recover refrigerant with proper recovery equipment before opening the original R-12 system. Immediately plug open fittings to keep moisture out. Apply clean compressor oil to the O-rings before reconnecting, and keep oil off the fitting nuts. Evacuate, charge and leak-test after repair."
  },
  "confidence": "fsm",
  "sources": [
    {
      "source": "fsm-1992",
      "page": "U–37 (PDF p. 1029)",
      "as_printed": "Receiver/drier inlet and outlet: 9.8—20 N·m (1.0—2.0 m-kg, 7.2—14 ft-lb)",
      "verified_years": [
        1992,
        1992
      ],
      "torque": {
        "nm": [
          9.8,
          20
        ],
        "kgfm": [
          1,
          2
        ],
        "ftlb": [
          7.2,
          14
        ]
      },
      "document": {
        "id": "fsm-1992",
        "tier": 1,
        "title": "1992 Mazda MX-5 Miata Workshop Manual",
        "part_number": "1271-10-91G (9999-95-0428-92)",
        "covers": [
          {
            "gen": "NA",
            "years": [
              1992,
              1992
            ],
            "engines": [
              "B6"
            ]
          }
        ],
        "note": "Cover identifies model year 1992; the download folder name is not evidence for 1993."
      }
    }
  ],
  "jobs": [],
  "system": "hvac",
  "component": "combined-audit-2026-10",
  "componentName": "Factory early HVAC service settings",
  "sequence_diagrams": [],
  "url": "https://miatatorque.com/spec/ac-receiver-drier-inlet-outlet-fittings-1992/"
}
```