# A/C refrigerant container storage temperature limit (2001–2004)

Canonical URL: https://miatatorque.com/spec/ac-refrigerant-container-storage-temperature-2003-2004/

Applicability: NB 2003–2004 (BP-Z3); NB 2001–2002 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 mechanical carry-over policy, checked against coverless publication 1719-1U-01G. Its exact edition/market remains unconfirmed; this does not establish independently verified model years.

Confidence: fsm

Store the refrigerant container below 40 °C {104 °F}.

Always confirm against your factory manual. Match every restriction and follow all stages and procedure notes. Disputed claims must not be automatically resolved. The complete record below preserves every printed unit, source claim and procedure.

```json
{
  "id": "ac-refrigerant-container-storage-temperature-2003-2004",
  "name": "A/C refrigerant container storage temperature limit (2001–2004)",
  "aliases": [],
  "applies_to": [
    {
      "gen": "NB",
      "years": [
        2003,
        2004
      ],
      "engines": [
        "BP-Z3"
      ]
    },
    {
      "gen": "NB",
      "years": [
        2001,
        2002
      ],
      "engines": [
        "BP-Z3"
      ],
      "note": "2001–2002 applicability follows the owner-approved early-NB2 mechanical carry-over policy, checked against coverless publication 1719-1U-01G. Its exact edition/market remains unconfirmed; this does not establish independently verified model years."
    }
  ],
  "kind": "non-torque",
  "value_text": "Store the refrigerant container below 40 °C {104 °F}.",
  "procedure": {
    "notes": "Applies to storage of the pressurized refrigerant container used for servicing the original R134a system. This is a container storage limit, rather than an ambient-temperature condition for a vehicle pressure or cooling-performance test."
  },
  "confidence": "fsm",
  "sources": [
    {
      "source": "fsm-2003",
      "page": "Refrigerant System Service Warnings (PDF pp. 1602, 1603)",
      "as_printed": "The refrigerant container is highly pressurized. If it is subjected to high heat, it could explode, scattering metal fragments and liquid refrigerant that can seriously injure you. Store the refrigerant at temperatures below 40 °C {104 °F}.",
      "verified_years": [
        2003,
        2003
      ],
      "document": {
        "id": "fsm-2003",
        "tier": 1,
        "title": "2003 Mazda MX-5 Miata Workshop Manual (electronic manual capture)",
        "covers": [
          {
            "gen": "NB",
            "years": [
              2003,
              2003
            ],
            "engines": [
              "BP-Z3"
            ]
          }
        ],
        "note": "Normally aspirated BP procedures audited; turbo procedures are covered separately."
      }
    },
    {
      "source": "fsm-2004",
      "page": "Refrigerant System Service Warnings (PDF pp. 1598, 1599)",
      "as_printed": "The refrigerant container is highly pressurized. If it is subjected to high heat, it could explode, scattering metal fragments and liquid refrigerant that can seriously injure you. Store the refrigerant at temperatures below 40 °C {104 °F}.",
      "verified_years": [
        2004,
        2004
      ],
      "document": {
        "id": "fsm-2004",
        "tier": 1,
        "title": "2004 Mazda MX-5 Miata Workshop Manual (electronic manual capture)",
        "covers": [
          {
            "gen": "NB",
            "years": [
              2004,
              2004
            ],
            "engines": [
              "BP-Z3"
            ]
          }
        ],
        "note": "Normally aspirated BP procedures audited; turbo procedures are covered separately."
      }
    },
    {
      "source": "workshop-1719-1u-01g",
      "page": "07–10–1 (PDF p. 738)",
      "as_printed": "Store the refrigerant at temperatures below 40 °C {104 °F}.",
      "note": "Visually checked against the original page. Early-NB2 mechanical use authorized by owner; exact full-document edition and market remain unconfirmed.",
      "document": {
        "id": "workshop-1719-1u-01g",
        "tier": 1,
        "title": "Mazda MX-5 Workshop Manual, publication 1719-1U-01G (2002 base edition)",
        "part_number": "1719-1U-01G",
        "covers": [
          {
            "gen": "NB",
            "years": [
              2002,
              2002
            ],
            "engines": [
              "BP-Z3"
            ]
          }
        ],
        "note": "Factory typeset document supplied in the purchased 2001–2005 package; 1,009 PDF pages. Running headers dated June 2001, A5U procedure identifiers. The copy omits its title/model-year cover. The owner accepted it as the tier-1 source for NB 2002 (BP-Z3) on 2026-10-23; it claims no coverage of 2001, later years or Mazdaspeed. A 2026-10-22 census finds the same 1719 running header on all 1,009 pages across 84 section files. Normalized extracted text exactly matches the archived 2002 samples at PDF pages 268 (timing belt), 526 (front brake), 925 (interior trim) and 931 (lighting). This supports a likely 2002 base-edition identity, but does not establish every page revision, regional applicability or a 2001–2005 coverage range. See docs/NB2-MANUAL-IDENTIFICATION.md for evidence and remaining checks. Reviewed HVAC pages corroborate the existing DENSO OIL9 records."
      }
    }
  ],
  "jobs": [],
  "system": "hvac",
  "component": "combined-audit-2026-10",
  "componentName": "Factory NB refrigerant service settings",
  "sequence_diagrams": [],
  "url": "https://miatatorque.com/spec/ac-refrigerant-container-storage-temperature-2003-2004/"
}
```