# A/C preliminary refrigerant leak-test pressure (2001–2004)

Canonical URL: https://miatatorque.com/spec/ac-refrigerant-leak-test-pressure-2003-2004/

Applicability: NB 2003 (BP-Z3); NB 2004 (BP-Z3); NB 2001–2002 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 mechanical carry-over policy, checked against coverless publication 1719-1U-01G. Its exact edition/market remains unconfirmed; this does not establish independently verified model years.

Confidence: fsm

After evacuation and the vacuum retention check, admit refrigerant through the low-side manifold valve to a low-side reading of 0.1 MPa {1 kgf/cm², 14 psi}; close the valve and check pipe/hose joints with a gas leak tester.

Always confirm against your factory manual. Match every restriction and follow all stages and procedure notes. Disputed claims must not be automatically resolved. The complete record below preserves every printed unit, source claim and procedure.

```json
{
  "id": "ac-refrigerant-leak-test-pressure-2003-2004",
  "name": "A/C preliminary refrigerant leak-test pressure (2001–2004)",
  "aliases": [],
  "applies_to": [
    {
      "gen": "NB",
      "years": [
        2003,
        2003
      ],
      "engines": [
        "BP-Z3"
      ]
    },
    {
      "gen": "NB",
      "years": [
        2004,
        2004
      ],
      "engines": [
        "BP-Z3"
      ]
    },
    {
      "gen": "NB",
      "years": [
        2001,
        2002
      ],
      "engines": [
        "BP-Z3"
      ],
      "note": "2001–2002 applicability follows the owner-approved early-NB2 mechanical carry-over policy, checked against coverless publication 1719-1U-01G. Its exact edition/market remains unconfirmed; this does not establish independently verified model years."
    }
  ],
  "kind": "non-torque",
  "value_text": "After evacuation and the vacuum retention check, admit refrigerant through the low-side manifold valve to a low-side reading of 0.1 MPa {1 kgf/cm², 14 psi}; close the valve and check pipe/hose joints with a gas leak tester.",
  "procedure": {
    "notes": "Original R-134a system. Complete the separate evacuation/retention procedure first, leaving the engine stopped and the high-side manifold valve closed. Open the tank valve and record the tank weight before opening the low-side manifold valve. At the stated low-side gauge reading, close that valve and use the detector on cooler pipe/hose joints. Retighten a loose leaking joint and retest. If it still leaks, recover the refrigerant, repair the joint and repeat evacuation before restarting charging. Only proceed to the staged mass charge once no leaks are found. This is a preliminary leak-test pressure, not a running-pressure criterion or full-charge indication. Never open the high-side manifold valve while the engine is running."
  },
  "confidence": "fsm",
  "sources": [
    {
      "source": "fsm-2003",
      "page": "Refrigerant charging (PDF p. 1615)",
      "as_printed": "When the low pressure side reading increases to 0.1 MPa {1 kgf/cm², 14 psi}, close the low pressure side valve of the manifold gauge.\nCheck for leaks from the cooler pipe/hose connections using a gas leak tester.",
      "verified_years": [
        2003,
        2003
      ],
      "document": {
        "id": "fsm-2003",
        "tier": 1,
        "title": "2003 Mazda MX-5 Miata Workshop Manual (electronic manual capture)",
        "covers": [
          {
            "gen": "NB",
            "years": [
              2003,
              2003
            ],
            "engines": [
              "BP-Z3"
            ]
          }
        ],
        "note": "Normally aspirated BP procedures audited; turbo procedures are covered separately."
      }
    },
    {
      "source": "fsm-2004",
      "page": "Refrigerant charging (PDF p. 1611)",
      "as_printed": "When the low pressure side reading increases to 0.1 MPa {1 kgf/cm², 14 psi}, close the low pressure side valve of the manifold gauge.\nCheck for leaks from the cooler pipe/hose connections using a gas leak tester.",
      "verified_years": [
        2004,
        2004
      ],
      "document": {
        "id": "fsm-2004",
        "tier": 1,
        "title": "2004 Mazda MX-5 Miata Workshop Manual (electronic manual capture)",
        "covers": [
          {
            "gen": "NB",
            "years": [
              2004,
              2004
            ],
            "engines": [
              "BP-Z3"
            ]
          }
        ],
        "note": "Normally aspirated BP procedures audited; turbo procedures are covered separately."
      }
    },
    {
      "source": "workshop-1719-1u-01g",
      "page": "07–10–5 (PDF p. 742)",
      "as_printed": "When the low-pressure side reading increases to 0.1 MPa {1 kgf/cm2, 14 psi}, close the low-pressure side valve of the manifold gauge.\nCheck for leaks from the cooler pipe/hose connections using a gas leak tester.",
      "note": "Visually checked against the original page. Early-NB2 mechanical use authorized by owner; exact full-document edition and market remain unconfirmed.",
      "document": {
        "id": "workshop-1719-1u-01g",
        "tier": 1,
        "title": "Mazda MX-5 Workshop Manual, publication 1719-1U-01G (2002 base edition)",
        "part_number": "1719-1U-01G",
        "covers": [
          {
            "gen": "NB",
            "years": [
              2002,
              2002
            ],
            "engines": [
              "BP-Z3"
            ]
          }
        ],
        "note": "Factory typeset document supplied in the purchased 2001–2005 package; 1,009 PDF pages. Running headers dated June 2001, A5U procedure identifiers. The copy omits its title/model-year cover. The owner accepted it as the tier-1 source for NB 2002 (BP-Z3) on 2026-10-23; it claims no coverage of 2001, later years or Mazdaspeed. A 2026-10-22 census finds the same 1719 running header on all 1,009 pages across 84 section files. Normalized extracted text exactly matches the archived 2002 samples at PDF pages 268 (timing belt), 526 (front brake), 925 (interior trim) and 931 (lighting). This supports a likely 2002 base-edition identity, but does not establish every page revision, regional applicability or a 2001–2005 coverage range. See docs/NB2-MANUAL-IDENTIFICATION.md for evidence and remaining checks. Reviewed HVAC pages corroborate the existing DENSO OIL9 records."
      }
    }
  ],
  "jobs": [],
  "system": "hvac",
  "component": "combined-audit-2026-10",
  "componentName": "Factory hvac service audit",
  "sequence_diagrams": [],
  "url": "https://miatatorque.com/spec/ac-refrigerant-leak-test-pressure-2003-2004/"
}
```