# A/C evaporator thermoswitch continuity (1990–1993)

Canonical URL: https://miatatorque.com/spec/ac-thermoswitch-continuity-1992/

Applicability: NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.; NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.

Confidence: fsm

Above 0°C (32°F): continuity; below 0°C (32°F): no continuity.

Always confirm against your factory manual. Match every restriction and follow all stages and procedure notes. Disputed claims must not be automatically resolved. The complete record below preserves every printed unit, source claim and procedure.

```json
{
  "id": "ac-thermoswitch-continuity-1992",
  "name": "A/C evaporator thermoswitch continuity (1990–1993)",
  "aliases": [],
  "applies_to": [
    {
      "gen": "NA",
      "years": [
        1992,
        1993
      ],
      "engines": [
        "B6"
      ],
      "note": "1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed."
    },
    {
      "gen": "NA",
      "years": [
        1990,
        1991
      ],
      "engines": [
        "B6"
      ],
      "note": "1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed."
    }
  ],
  "kind": "non-torque",
  "value_text": "Above 0°C (32°F): continuity; below 0°C (32°F): no continuity.",
  "procedure": {
    "notes": "For the removed-switch inspection, immerse the sensing bulb in an ice-water container and check continuity between the two switch terminals while monitoring sensing-bulb temperature. The source specifies behavior above and below zero, with no acceptance state exactly at zero. On vehicle, remove glove box, idle engine with A/C OFF and blower on highest for a few minutes; then turn blower OFF, stop engine, unplug thermoswitch and verify continuity. Cold evaporator below zero intentionally opens contacts. Replace thermoswitch if behavior is incorrect."
  },
  "confidence": "fsm",
  "sources": [
    {
      "source": "fsm-1992",
      "page": "U–36 (PDF p. 1028)",
      "as_printed": "Terminals Temperature Continuity\na—b Above 0°C (32°F) Yes\nBelow 0°C (32°F) No",
      "verified_years": [
        1992,
        1992
      ],
      "document": {
        "id": "fsm-1992",
        "tier": 1,
        "title": "1992 Mazda MX-5 Miata Workshop Manual",
        "part_number": "1271-10-91G (9999-95-0428-92)",
        "covers": [
          {
            "gen": "NA",
            "years": [
              1992,
              1992
            ],
            "engines": [
              "B6"
            ]
          }
        ],
        "note": "Cover identifies model year 1992; the download folder name is not evidence for 1993."
      }
    },
    {
      "source": "fsm-1990",
      "page": "U–34 (PDF p. 777)",
      "as_printed": "Terminals Temperature Continuity\na—b Above 0°C (32°F) Yes\nBelow 0°C (32°F) No",
      "verified_years": [
        1990,
        1990
      ],
      "note": "Visually checked against the original 1990 factory page, including printed units and component/test context.",
      "document": {
        "id": "fsm-1990",
        "tier": 1,
        "title": "1990 Mazda MX-5 Miata Workshop Manual",
        "part_number": "1193-10-89C",
        "covers": [
          {
            "gen": "NA",
            "years": [
              1990,
              1990
            ],
            "engines": [
              "B6"
            ]
          }
        ],
        "url": "https://archive.org/details/1990-mazda-mx-5-miata-workshop-manual_202411"
      }
    }
  ],
  "jobs": [],
  "system": "hvac",
  "component": "combined-audit-2026-10",
  "componentName": "Factory hvac service audit",
  "sequence_diagrams": [],
  "url": "https://miatatorque.com/spec/ac-thermoswitch-continuity-1992/"
}
```