# Automatic OD-case accumulator air operation check (1992–1993)

Canonical URL: https://miatatorque.com/spec/automatic-od-case-accumulator-air-test-1992/

Applicability: NA 1992–1993 (B6, 4AT) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.

Confidence: fsm

Air pressure maximum 392 kPa (4.0 kg/cm², 57 psi); apply air for no more than three seconds.

Always confirm against your factory manual. Match every restriction and follow all stages and procedure notes. Disputed claims must not be automatically resolved. The complete record below preserves every printed unit, source claim and procedure.

```json
{
  "id": "automatic-od-case-accumulator-air-test-1992",
  "name": "Automatic OD-case accumulator air operation check (1992–1993)",
  "aliases": [],
  "applies_to": [
    {
      "gen": "NA",
      "years": [
        1992,
        1993
      ],
      "engines": [
        "B6"
      ],
      "trans": [
        "4AT"
      ],
      "note": "1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed."
    }
  ],
  "kind": "non-torque",
  "value_text": "Air pressure maximum 392 kPa (4.0 kg/cm², 57 psi); apply air for no more than three seconds.",
  "procedure": {
    "notes": "During OD-case accumulator assembly, lubricate new piston seal rings with ATF and install them. Lubricate the spring and piston and install them in the OD case, pressing evenly on the piston outside edge to protect the rings. Fit a new ATF-coated O-ring to the accumulator plug, then install the plug and snap ring. Check accumulator operation by applying compressed air through the factory-identified passage. This is an assembled operation check, separate from using air to remove the accumulator plug, piston and spring during disassembly."
  },
  "confidence": "fsm",
  "sources": [
    {
      "source": "fsm-1992",
      "page": "K–67–K–68 (PDF pp. 459–460)",
      "as_printed": "Apply air for no more than three (3) seconds.\nCheck the accumulator operation by applying compressed\nair through the oil passage.\nAir pressure: 392 kPa (4.0kg/cm², 57 psi) max.",
      "verified_years": [
        1992,
        1992
      ],
      "document": {
        "id": "fsm-1992",
        "tier": 1,
        "title": "1992 Mazda MX-5 Miata Workshop Manual",
        "part_number": "1271-10-91G (9999-95-0428-92)",
        "covers": [
          {
            "gen": "NA",
            "years": [
              1992,
              1992
            ],
            "engines": [
              "B6"
            ]
          }
        ],
        "note": "Cover identifies model year 1992; the download folder name is not evidence for 1993."
      }
    }
  ],
  "jobs": [],
  "system": "transmission",
  "component": "release-validation-2026-11",
  "componentName": "Factory manual transmission specifications (1990)",
  "sequence_diagrams": [],
  "url": "https://miatatorque.com/spec/automatic-od-case-accumulator-air-test-1992/"
}
```