# Automatic TCM range-input voltage reference (1999–2000)

Canonical URL: https://miatatorque.com/spec/automatic-tcm-range-input-voltage-1999/

Applicability: NB 1999–2000 (BP-4W, 4AT) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.

Confidence: fsm

A: B+ in1; B: B+ in2; C: B+ inD; D: B+ inR; F: B+ inP orN. Each is0 V in other selector positions/ranges.

Always confirm against your factory manual. Match every restriction and follow all stages and procedure notes. Disputed claims must not be automatically resolved. The complete record below preserves every printed unit, source claim and procedure.

```json
{
  "id": "automatic-tcm-range-input-voltage-1999",
  "name": "Automatic TCM range-input voltage reference (1999–2000)",
  "aliases": [],
  "applies_to": [
    {
      "gen": "NB",
      "years": [
        1999,
        2000
      ],
      "engines": [
        "BP-4W"
      ],
      "trans": [
        "4AT"
      ],
      "note": "1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed."
    }
  ],
  "kind": "non-torque",
  "value_text": "A: B+ in1; B: B+ in2; C: B+ inD; D: B+ inR; F: B+ inP orN. Each is0 V in other selector positions/ranges.",
  "procedure": {
    "notes": "Factory TCM Terminal Voltage Chart reference data. Use the original labelled TCM terminal chart with confirmed connector identity and viewing direction; do not infer a connector face or pin position from an unlabeled sketch. Use TCM terminal AP for the negative meter lead as required by the factory note, rather than a general body-ground substitute. Turn ignition ON except for a row explicitly requiring OFF; keep each printed engine, selector and operating condition. Inspect related devices and wiring before condemning the TCM from an incorrect reading. These powered voltage checks are not isolated component resistance tests. A/B/C/D/F identify TCM terminals, not transmission-switch connector terminal letters. Check the matching single selector position/range for each input and the remaining positions for0V. B+ denotes the source battery-supply reference, not a fixed numeric voltage."
  },
  "confidence": "fsm",
  "sources": [
    {
      "source": "fsm-1999",
      "page": "05–13–18–19 (PDF pp. 495–496)",
      "as_printed": "Terminal\nTransmission range switch\nA\n1 range\nB+\nB\n2 range\nB+\nC\nD range\nB+\nD\nR position\nB+\nF\nP or N position\nB+\nVoltage (V)\n0",
      "verified_years": [
        1999,
        1999
      ],
      "document": {
        "id": "fsm-1999",
        "tier": 1,
        "title": "1999 Mazda MX-5 Miata Workshop Manual",
        "covers": [
          {
            "gen": "NB",
            "years": [
              1999,
              2000
            ],
            "engines": [
              "BP-4W"
            ]
          }
        ],
        "url": "https://www.mellens.net/mazda/Mazda-Miata-1999-2001.pdf"
      }
    }
  ],
  "jobs": [],
  "system": "transmission",
  "component": "release-validation-1999-2026-11",
  "componentName": "Factory transmission inspections (1999)",
  "sequence_diagrams": [],
  "url": "https://miatatorque.com/spec/automatic-tcm-range-input-voltage-1999/"
}
```