# Automatic torque converter internal washing (1992–1993)

Canonical URL: https://miatatorque.com/spec/automatic-torque-converter-internal-washing-1992/

Applicability: NA 1992–1993 (B6, 4AT) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.

Confidence: fsm

Solvent wash quantity: 0.5 liter (0.5 US qt, 0.4 Imp qt), followed by an ATF rinse.

Always confirm against your factory manual. Match every restriction and follow all stages and procedure notes. Disputed claims must not be automatically resolved. The complete record below preserves every printed unit, source claim and procedure.

```json
{
  "id": "automatic-torque-converter-internal-washing-1992",
  "name": "Automatic torque converter internal washing (1992–1993)",
  "aliases": [],
  "applies_to": [
    {
      "gen": "NA",
      "years": [
        1992,
        1993
      ],
      "engines": [
        "B6"
      ],
      "trans": [
        "4AT"
      ],
      "note": "1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed."
    }
  ],
  "kind": "non-torque",
  "value_text": "Solvent wash quantity: 0.5 liter (0.5 US qt, 0.4 Imp qt), followed by an ATF rinse.",
  "procedure": {
    "notes": "With the converter removed, drain the remaining ATF. Add the printed solvent quantity, shake the converter to clean inside and pour out the solvent. Then add ATF, shake again and pour out the ATF. This is the factory internal washing sequence, not the installed converter fill capacity; no solvent identity, soaking duration or ATF rinse quantity is specified here. Inspect the converter exterior for cracks/damage and remove any rust from the pilot hub or boss as directed by the adjacent inspection."
  },
  "confidence": "fsm",
  "sources": [
    {
      "source": "fsm-1992",
      "page": "K–49 (PDF p. 441)",
      "as_printed": "Washing inside the converter\n1. Drain any ATF remaining in the converter.\n2. Pour in solvent (0.5 liter, 0.5 US qt, 0.4 Imp qt).\n3. Shake the converter to clean the inside. Pour out the solvent.\n4. Pour in ATF.\n5. Shake the converter to clean the inside. Pour out the ATF.",
      "verified_years": [
        1992,
        1992
      ],
      "document": {
        "id": "fsm-1992",
        "tier": 1,
        "title": "1992 Mazda MX-5 Miata Workshop Manual",
        "part_number": "1271-10-91G (9999-95-0428-92)",
        "covers": [
          {
            "gen": "NA",
            "years": [
              1992,
              1992
            ],
            "engines": [
              "B6"
            ]
          }
        ],
        "note": "Cover identifies model year 1992; the download folder name is not evidence for 1993."
      }
    }
  ],
  "jobs": [],
  "system": "transmission",
  "component": "release-validation-2026-11",
  "componentName": "Factory manual transmission specifications (1990)",
  "sequence_diagrams": [],
  "url": "https://miatatorque.com/spec/automatic-torque-converter-internal-washing-1992/"
}
```