# Factory battery load-test thresholds (1999–2000)

Canonical URL: https://miatatorque.com/spec/battery-load-test-1999/

Applicability: NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.

Confidence: fsm

S46A24L(S): 105 A; record voltage after 15 seconds. Minimum voltage by approximate battery temperature: 21 °C {70 °F}: 9.6 V; 15 °C {60 °F}: 9.5 V; 10 °C {50 °F}: 9.4 V; 4 °C {40 °F}: 9.3 V; −1 °C {30 °F}: 9.1 V; −7 °C {20 °F}: 8.9 V; −12 °C {10 °F}: 8.7 V; −18 °C {0 °F}: 8.5 V.

Always confirm against your factory manual. Match every restriction and follow all stages and procedure notes. Disputed claims must not be automatically resolved. The complete record below preserves every printed unit, source claim and procedure.

```json
{
  "id": "battery-load-test-1999",
  "name": "Factory battery load-test thresholds (1999–2000)",
  "aliases": [],
  "applies_to": [
    {
      "gen": "NB",
      "years": [
        1999,
        2000
      ],
      "engines": [
        "BP-4W"
      ],
      "note": "1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed."
    }
  ],
  "kind": "non-torque",
  "value_text": "S46A24L(S): 105 A; record voltage after 15 seconds. Minimum voltage by approximate battery temperature: 21 °C {70 °F}: 9.6 V; 15 °C {60 °F}: 9.5 V; 10 °C {50 °F}: 9.4 V; 4 °C {40 °F}: 9.3 V; −1 °C {30 °F}: 9.1 V; −7 °C {20 °F}: 8.9 V; −12 °C {10 °F}: 8.7 V; −18 °C {0 °F}: 8.5 V.",
  "procedure": {
    "notes": "For the original S46A24L(S) battery only. First measure open-circuit battery voltage. Above 12.4 V proceeds to the load test; below 12.4 V calls for quick charging for 30 minutes and rechecking. If still below 12.4 V replace the battery; above proceeds to the load test. The printed above/below branches do not assign exactly 12.4 V. Use a battery load tester at 105 A and read voltage after 15 seconds, using the approximate battery-temperature row. The factory pass question asks whether voltage is more than the specification; replace if not. Do not use this load setting for an unspecified replacement battery. For the prerequisite recharge, stop the engine and turn all accessories off, remove battery negative first and install it last. Keep flames, heat and sparks away. Follow the factory removed-battery water-pan cooling procedure: water about halfway up the case, keeping the top dry. The listed quick-charge current is 20 A and the maximum duration is 30 minutes. After recharge verify voltage remains above 12.4 V for more than one hour; replace if incorrect."
  },
  "confidence": "fsm",
  "sources": [
    {
      "source": "fsm-1999",
      "page": "01–17–1 (PDF p. 269)",
      "as_printed": "Quick charge for 30 minutes\nand reinspect voltage.\nApply test load (see test load\nchart) to battery using a\nbattery load tester and record\nbattery voltage after 15\nseconds. Is voltage more than\nspecification?\nTest load chart\nBattery\nS46A24L(S)\nLoad (A)\n105\nApproximate\nbattery temp.\nMinimum voltage (V)\n21 °C {70 °F}\n9.6\n15 °C {60 °F}\n9.5\n10 °C {50 °F}\n9.4\n4 °C {40 °F}\n9.3\n−1 °C {30 °F}\n9.1\n−7 °C {20 °F}\n8.9\n−12 °C {10 °F}\n8.7\n−18 °C {0 °F}\n8.5",
      "verified_years": [
        1999,
        1999
      ],
      "document": {
        "id": "fsm-1999",
        "tier": 1,
        "title": "1999 Mazda MX-5 Miata Workshop Manual",
        "covers": [
          {
            "gen": "NB",
            "years": [
              1999,
              2000
            ],
            "engines": [
              "BP-4W"
            ]
          }
        ],
        "url": "https://www.mellens.net/mazda/Mazda-Miata-1999-2001.pdf"
      }
    },
    {
      "source": "fsm-1999",
      "page": "01–17–2 (PDF p. 270)",
      "as_printed": "Do not quick charge for over 30 minutes. It\nwill damage the battery.\nAfter the battery has been recharged, measure\nthe battery positive voltage and verify that the\nbattery keeps specified voltage for more than 1\nhour.\nSpecification\nAbove 12.4 V",
      "verified_years": [
        1999,
        1999
      ],
      "document": {
        "id": "fsm-1999",
        "tier": 1,
        "title": "1999 Mazda MX-5 Miata Workshop Manual",
        "covers": [
          {
            "gen": "NB",
            "years": [
              1999,
              2000
            ],
            "engines": [
              "BP-4W"
            ]
          }
        ],
        "url": "https://www.mellens.net/mazda/Mazda-Miata-1999-2001.pdf"
      }
    },
    {
      "source": "fsm-1999",
      "page": "01–50–2 (PDF p.313)",
      "as_printed": "Test load chart\n(A)\nBattery type\nS46A24L (S)\n105",
      "verified_years": [
        1999,
        1999
      ],
      "note": "Original1999 technical table checked against the complete current record and its separately cited procedure; existing value and applicability retained.",
      "document": {
        "id": "fsm-1999",
        "tier": 1,
        "title": "1999 Mazda MX-5 Miata Workshop Manual",
        "covers": [
          {
            "gen": "NB",
            "years": [
              1999,
              2000
            ],
            "engines": [
              "BP-4W"
            ]
          }
        ],
        "url": "https://www.mellens.net/mazda/Mazda-Miata-1999-2001.pdf"
      }
    }
  ],
  "jobs": [],
  "system": "ignition-electrical",
  "component": "release-validation-1999-2026-11",
  "componentName": "Factory sensor inspections (1999)",
  "sequence_diagrams": [],
  "url": "https://miatatorque.com/spec/battery-load-test-1999/"
}
```