# Factory battery load-test thresholds (2001–2004)

Canonical URL: https://miatatorque.com/spec/battery-load-test-2003-2004/

Applicability: NB 2003 (BP-Z3); NB 2004 (BP-Z3); NB 2001–2002 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 carry-over policy, with hardware, test setup and connector perspective compared against publication 1719-1U-01G. Its existing owner-accepted 2002 source coverage is unchanged; 2001 is carry-over, not an independently verified year.

Confidence: fsm

S46A24L(S): apply 105 A for 15 s. Minimum voltage by approximate battery temperature: 21°C (70°F) 9.6 V; 15°C (59°F) 9.5 V; 10°C (50°F) 9.4 V; 4°C (39°F) 9.3 V; −1°C (30°F) 9.1 V; −7°C (19°F) 8.9 V; −12°C (10°F) 8.7 V; −18°C (0°F) 8.5 V.

Always confirm against your factory manual. Match every restriction and follow all stages and procedure notes. Disputed claims must not be automatically resolved. The complete record below preserves every printed unit, source claim and procedure.

```json
{
  "id": "battery-load-test-2003-2004",
  "name": "Factory battery load-test thresholds (2001–2004)",
  "aliases": [],
  "applies_to": [
    {
      "gen": "NB",
      "years": [
        2003,
        2003
      ],
      "engines": [
        "BP-Z3"
      ]
    },
    {
      "gen": "NB",
      "years": [
        2004,
        2004
      ],
      "engines": [
        "BP-Z3"
      ]
    },
    {
      "gen": "NB",
      "years": [
        2001,
        2002
      ],
      "engines": [
        "BP-Z3"
      ],
      "note": "2001–2002 applicability follows the owner-approved early-NB2 carry-over policy, with hardware, test setup and connector perspective compared against publication 1719-1U-01G. Its existing owner-accepted 2002 source coverage is unchanged; 2001 is carry-over, not an independently verified year."
    }
  ],
  "kind": "non-torque",
  "value_text": "S46A24L(S): apply 105 A for 15 s. Minimum voltage by approximate battery temperature: 21°C (70°F) 9.6 V; 15°C (59°F) 9.5 V; 10°C (50°F) 9.4 V; 4°C (39°F) 9.3 V; −1°C (30°F) 9.1 V; −7°C (19°F) 8.9 V; −12°C (10°F) 8.7 V; −18°C (0°F) 8.5 V.",
  "procedure": {
    "notes": "Applies to the listed factory S46A24L(S) battery. First measure open-circuit voltage: 12.4 V or higher proceeds to load testing. If lower, quick charge for 30 minutes and reinspect; replace if still below 12.4 V. Use a battery load tester to apply 105 A and read voltage after 15 seconds. Factory pass question asks whether voltage is more than the temperature-specific specification; replace if not. Load and preparation are 2003 PDF 782 / 2004 PDF 811. Do not use the 105 A setting for an unspecified replacement battery."
  },
  "confidence": "fsm",
  "sources": [
    {
      "source": "fsm-2003",
      "page": "Factory battery load-test thresholds (2003–2004) (PDF p. 783)",
      "as_printed": "Approximate battery temp. Minimum voltage (V)\n21°C {70°F} 9.6\n15°C {59°F} 9.5\n10°C {50°F} 9.4\n4°C {39°F} 9.3\n−1°C {30°F} 9.1\n−7°C {19°F} 8.9\n−12°C {10°F} 8.7\n−18°C {0°F} 8.5",
      "verified_years": [
        2003,
        2003
      ],
      "document": {
        "id": "fsm-2003",
        "tier": 1,
        "title": "2003 Mazda MX-5 Miata Workshop Manual (electronic manual capture)",
        "covers": [
          {
            "gen": "NB",
            "years": [
              2003,
              2003
            ],
            "engines": [
              "BP-Z3"
            ]
          }
        ],
        "note": "Normally aspirated BP procedures audited; turbo procedures are covered separately."
      }
    },
    {
      "source": "fsm-2004",
      "page": "Factory battery load-test thresholds (2003–2004) (PDF p. 812)",
      "as_printed": "Approximate battery temp. Minimum voltage (V)\n21°C {70°F} 9.6\n15°C {59°F} 9.5\n10°C {50°F} 9.4\n4°C {39°F} 9.3\n−1°C {30°F} 9.1\n−7°C {19°F} 8.9\n−12°C {10°F} 8.7\n−18°C {0°F} 8.5",
      "verified_years": [
        2004,
        2004
      ],
      "document": {
        "id": "fsm-2004",
        "tier": 1,
        "title": "2004 Mazda MX-5 Miata Workshop Manual (electronic manual capture)",
        "covers": [
          {
            "gen": "NB",
            "years": [
              2004,
              2004
            ],
            "engines": [
              "BP-Z3"
            ]
          }
        ],
        "note": "Normally aspirated BP procedures audited; turbo procedures are covered separately."
      }
    },
    {
      "source": "workshop-1719-1u-01g",
      "page": "01–17–2 (PDF p. 348)",
      "as_printed": "Apply test load (see test load chart) to battery using a battery load tester and record battery voltage after 15 s. Is voltage more than specification?\nLoad test chart\nBattery\nS46A24L(S)\nLoad (A)\n105\nApproximate battery temp.\n21°C {70°F}\n15°C {59°F}\n10°C {50°F}\n4°C {39°F}\n–1°C {30°F}\n–7°C {19°F}\n–12°C {10°F}\n–18°C { 0°F}\nMinimum voltage (V)\n9.6\n9.5\n9.4\n9.3\n9.1\n8.9\n8.7\n8.5",
      "note": "Visually checked against the original factory page; printed units and component/test context retained. Source edition/market limitations remain as documented; no additional verified years assigned.",
      "document": {
        "id": "workshop-1719-1u-01g",
        "tier": 1,
        "title": "Mazda MX-5 Workshop Manual, publication 1719-1U-01G (2002 base edition)",
        "part_number": "1719-1U-01G",
        "covers": [
          {
            "gen": "NB",
            "years": [
              2002,
              2002
            ],
            "engines": [
              "BP-Z3"
            ]
          }
        ],
        "note": "Factory typeset document supplied in the purchased 2001–2005 package; 1,009 PDF pages. Running headers dated June 2001, A5U procedure identifiers. The copy omits its title/model-year cover. The owner accepted it as the tier-1 source for NB 2002 (BP-Z3) on 2026-10-23; it claims no coverage of 2001, later years or Mazdaspeed. A 2026-10-22 census finds the same 1719 running header on all 1,009 pages across 84 section files. Normalized extracted text exactly matches the archived 2002 samples at PDF pages 268 (timing belt), 526 (front brake), 925 (interior trim) and 931 (lighting). This supports a likely 2002 base-edition identity, but does not establish every page revision, regional applicability or a 2001–2005 coverage range. See docs/NB2-MANUAL-IDENTIFICATION.md for evidence and remaining checks. Reviewed HVAC pages corroborate the existing DENSO OIL9 records."
      }
    },
    {
      "source": "fsm-2003",
      "page": "Battery Inspection — decision flow and load (PDF p.782)",
      "as_printed": "Measure open circuit voltage of battery.\n12.4 V or more\nQuick charge for 30 min and reinspect voltage.\nApply test load (see test load chart) to battery using a battery load tester and record battery voltage after 15 s. Is voltage more than specification?\nS46A24L(S)\n105",
      "verified_years": [
        2003,
        2003
      ],
      "note": "Complete current record preserves original decision flow: low initial voltage leads to30min quickcharge/recheck; still below12.4 replace; otherwise105A15s test at battery temperature. Flow asks more than specification; no replacement-battery current inferred.",
      "document": {
        "id": "fsm-2003",
        "tier": 1,
        "title": "2003 Mazda MX-5 Miata Workshop Manual (electronic manual capture)",
        "covers": [
          {
            "gen": "NB",
            "years": [
              2003,
              2003
            ],
            "engines": [
              "BP-Z3"
            ]
          }
        ],
        "note": "Normally aspirated BP procedures audited; turbo procedures are covered separately."
      }
    },
    {
      "source": "fsm-2004",
      "page": "Battery Inspection — decision flow and load (PDF p.811)",
      "as_printed": "Measure open circuit voltage of battery.\n12.4 V or more\nQuick charge for 30 min and reinspect voltage.\nApply test load (see test load chart) to battery using a battery load tester and record battery voltage after 15 s. Is voltage more than specification?\nS46A24L(S)\n105",
      "verified_years": [
        2004,
        2004
      ],
      "note": "Original flow:initialbelow12.4leads30minquickcharge/recheck;stillbelow12.4replace,otherwise105A15s test againsttemperaturetable812. Full existing factory-battery record retains strict more-than wording;notuniversalreplacementbattery load.",
      "document": {
        "id": "fsm-2004",
        "tier": 1,
        "title": "2004 Mazda MX-5 Miata Workshop Manual (electronic manual capture)",
        "covers": [
          {
            "gen": "NB",
            "years": [
              2004,
              2004
            ],
            "engines": [
              "BP-Z3"
            ]
          }
        ],
        "note": "Normally aspirated BP procedures audited; turbo procedures are covered separately."
      }
    },
    {
      "source": "fsm-2004",
      "page": "Engine Technical Data (PDF p.930)",
      "as_printed": "Battery\nTest load chart\n(A)\nBattery type S46A24L (S)\n105",
      "verified_years": [
        2004,
        2004
      ],
      "note": "Originalactual2004tableagreescompletecurrentrecord. Listedfactorybatteryloadonly;completecurrent811–812open-circuitvoltage/quickchargebranch/105A15seconds/temperature-specificvoltageandstrictpassquestionpreserved. No universalreplacementbatteryload. No applicability extension.",
      "document": {
        "id": "fsm-2004",
        "tier": 1,
        "title": "2004 Mazda MX-5 Miata Workshop Manual (electronic manual capture)",
        "covers": [
          {
            "gen": "NB",
            "years": [
              2004,
              2004
            ],
            "engines": [
              "BP-Z3"
            ]
          }
        ],
        "note": "Normally aspirated BP procedures audited; turbo procedures are covered separately."
      }
    }
  ],
  "jobs": [],
  "system": "ignition-electrical",
  "component": "combined-audit-2026-10",
  "componentName": "Factory ignition-electrical service audit",
  "sequence_diagrams": [],
  "url": "https://miatatorque.com/spec/battery-load-test-2003-2004/"
}
```