# Canister drain-cut valve airflow test (1999–2000)

Canonical URL: https://miatatorque.com/spec/canister-drain-cut-valve-airflow-1999/

Applicability: NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.

Confidence: fsm

Unpowered: terminal A–B continuity and airflow between ports A and B. Terminal A battery positive/B ground: no airflow between ports A and B.

Always confirm against your factory manual. Match every restriction and follow all stages and procedure notes. Disputed claims must not be automatically resolved. The complete record below preserves every printed unit, source claim and procedure.

```json
{
  "id": "canister-drain-cut-valve-airflow-1999",
  "name": "Canister drain-cut valve airflow test (1999–2000)",
  "aliases": [],
  "applies_to": [
    {
      "gen": "NB",
      "years": [
        1999,
        2000
      ],
      "engines": [
        "BP-4W"
      ],
      "note": "1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed."
    }
  ],
  "kind": "non-torque",
  "value_text": "Unpowered: terminal A–B continuity and airflow between ports A and B. Terminal A battery positive/B ground: no airflow between ports A and B.",
  "procedure": {
    "notes": "Perform only when directed after the factory evaporative-emission control simulation test. Disconnect battery negative, raise and support the rear on safety stands and remove the CDCV using its removal procedure. Verify electrical continuity A–B unpowered and the table airflow conditions. Apply battery positive to electrical A and ground to electrical B for the powered row. In the depicted valve connector B is left and A right; pneumatic A is the upper upright port and B the lower upright port. These electrical and pneumatic letters refer to different features. Replace the valve if incorrect; if it passes but simulation fails, inspect hoses and specified circuits using the factory diagnostic procedure. Install the hose to its stopper."
  },
  "confidence": "fsm",
  "sources": [
    {
      "source": "fsm-1999",
      "page": "01–16–7–8 (PDF pp. 263–264)",
      "as_printed": "Perform the following test only when directed.\nInspect airflow between the ports under the\nfollowing conditions.",
      "verified_years": [
        1999,
        1999
      ],
      "document": {
        "id": "fsm-1999",
        "tier": 1,
        "title": "1999 Mazda MX-5 Miata Workshop Manual",
        "covers": [
          {
            "gen": "NB",
            "years": [
              1999,
              2000
            ],
            "engines": [
              "BP-4W"
            ]
          }
        ],
        "url": "https://www.mellens.net/mazda/Mazda-Miata-1999-2001.pdf"
      }
    }
  ],
  "jobs": [],
  "system": "fuel-intake",
  "component": "release-validation-1999-2026-11",
  "componentName": "Factory service specifications (1999)",
  "sequence_diagrams": [],
  "url": "https://miatatorque.com/spec/canister-drain-cut-valve-airflow-1999/"
}
```