# Cooling fan relay continuity test (1990–1991)

Canonical URL: https://miatatorque.com/spec/cooling-fan-relay-continuity-1990/

Applicability: NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.

Confidence: fsm

Unpowered: A–C open, B–D continuity; with 12 V across B–D: A–C continuity

Always confirm against your factory manual. Match every restriction and follow all stages and procedure notes. Disputed claims must not be automatically resolved. The complete record below preserves every printed unit, source claim and procedure.

```json
{
  "id": "cooling-fan-relay-continuity-1990",
  "name": "Cooling fan relay continuity test (1990–1991)",
  "aliases": [],
  "applies_to": [
    {
      "gen": "NA",
      "years": [
        1990,
        1991
      ],
      "engines": [
        "B6"
      ],
      "note": "1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed."
    }
  ],
  "kind": "non-torque",
  "value_text": "Unpowered: A–C open, B–D continuity; with 12 V across B–D: A–C continuity",
  "procedure": {
    "notes": "Test the disconnected cooling fan relay with an ohmmeter, using the factory terminal letters. B and D are the coil terminals; A and C are the switched contacts. First check the unpowered pairs, then apply 12 V across B and D and check A–C. Replace the relay if either test fails. Do not apply this terminal assignment to a different relay or to an unidentified harness connector."
  },
  "confidence": "fsm",
  "sources": [
    {
      "source": "fsm-1990",
      "page": "E–14 (PDF p. 144)",
      "as_printed": "Terminal  Continuity\nA—C  No\nB—D  Yes\nApply 12V between terminals B and D.\nCheck for continuity between terminals A and C.\nIf not as specified, replace the fan relay.",
      "verified_years": [
        1990,
        1990
      ],
      "document": {
        "id": "fsm-1990",
        "tier": 1,
        "title": "1990 Mazda MX-5 Miata Workshop Manual",
        "part_number": "1193-10-89C",
        "covers": [
          {
            "gen": "NA",
            "years": [
              1990,
              1990
            ],
            "engines": [
              "B6"
            ]
          }
        ],
        "url": "https://archive.org/details/1990-mazda-mx-5-miata-workshop-manual_202411"
      }
    }
  ],
  "jobs": [],
  "system": "cooling",
  "component": "release-validation-2026-11",
  "componentName": "Factory service specifications",
  "sequence_diagrams": [],
  "url": "https://miatatorque.com/spec/cooling-fan-relay-continuity-1990/"
}
```
