# Door-lock switch resistance and continuity — non-turbo (2001–2004)

Canonical URL: https://miatatorque.com/spec/door-lock-switch-resistance-continuity-2003-2004/

Applicability: NB 2003–2004 (BP-Z3); NB 2001–2002 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 carry-over policy, with hardware and test setup compared against publication 1719-1U-01G. Its existing owner-accepted 2002 source coverage is unchanged; 2001 is carry-over, not an independently verified year.

Confidence: fsm

Across the two switch contacts: LOCK 950–1050 Ω; UNLOCK direct continuity.

Always confirm against your factory manual. Match every restriction and follow all stages and procedure notes. Disputed claims must not be automatically resolved. The complete record below preserves every printed unit, source claim and procedure.

```json
{
  "id": "door-lock-switch-resistance-continuity-2003-2004",
  "name": "Door-lock switch resistance and continuity — non-turbo (2001–2004)",
  "aliases": [],
  "applies_to": [
    {
      "gen": "NB",
      "years": [
        2003,
        2004
      ],
      "engines": [
        "BP-Z3"
      ]
    },
    {
      "gen": "NB",
      "years": [
        2001,
        2002
      ],
      "engines": [
        "BP-Z3"
      ],
      "note": "2001–2002 applicability follows the owner-approved early-NB2 carry-over policy, with hardware and test setup compared against publication 1719-1U-01G. Its existing owner-accepted 2002 source coverage is unchanged; 2001 is carry-over, not an independently verified year."
    }
  ],
  "kind": "non-torque",
  "value_text": "Across the two switch contacts: LOCK 950–1050 Ω; UNLOCK direct continuity.",
  "procedure": {
    "notes": "Disconnect battery negative and remove/unplug the original door-lock switch. Measure between its only two contacts A and B with an ohmmeter. The source component terminal-face view, with the small crossed key above, places B on the left and A on the right; this two-contact resistance/continuity check is independent of meter-lead polarity. LOCK is the resistor path, not a direct short; UNLOCK is direct continuity. The internal schematic labels its nominal resistor 1 KΩ, while the acceptance table gives 950–1050 Ω. No resting-state acceptance is printed in this table. Replace the switch if the stated checks fail."
  },
  "confidence": "fsm",
  "sources": [
    {
      "source": "fsm-2003",
      "page": "Door Lock Switch Removal/Installation; Inspection (PDF pp. 1932, 1933)",
      "as_printed": "Lock\nUnlock\nR: 950—1050Ω",
      "verified_years": [
        2003,
        2003
      ],
      "document": {
        "id": "fsm-2003",
        "tier": 1,
        "title": "2003 Mazda MX-5 Miata Workshop Manual (electronic manual capture)",
        "covers": [
          {
            "gen": "NB",
            "years": [
              2003,
              2003
            ],
            "engines": [
              "BP-Z3"
            ]
          }
        ],
        "note": "Normally aspirated BP procedures audited; turbo procedures are covered separately."
      }
    },
    {
      "source": "fsm-2004",
      "page": "Door Lock Switch Removal/Installation; Inspection (PDF pp. 1928, 1929)",
      "as_printed": "Lock\nUnlock\nR: 950—1050Ω",
      "verified_years": [
        2004,
        2004
      ],
      "document": {
        "id": "fsm-2004",
        "tier": 1,
        "title": "2004 Mazda MX-5 Miata Workshop Manual (electronic manual capture)",
        "covers": [
          {
            "gen": "NB",
            "years": [
              2004,
              2004
            ],
            "engines": [
              "BP-Z3"
            ]
          }
        ],
        "note": "Normally aspirated BP procedures audited; turbo procedures are covered separately."
      }
    },
    {
      "source": "workshop-1719-1u-01g",
      "page": "09–14–7 (PDF p. 878)",
      "as_printed": "Position\nTerminal\nA B\nLock\nUnlock\nR: 950—1050 Ω",
      "note": "Visually checked against the original factory page; printed units and component/test context retained. Source edition/market limitations remain as documented; no additional verified years assigned.",
      "document": {
        "id": "workshop-1719-1u-01g",
        "tier": 1,
        "title": "Mazda MX-5 Workshop Manual, publication 1719-1U-01G (2002 base edition)",
        "part_number": "1719-1U-01G",
        "covers": [
          {
            "gen": "NB",
            "years": [
              2002,
              2002
            ],
            "engines": [
              "BP-Z3"
            ]
          }
        ],
        "note": "Factory typeset document supplied in the purchased 2001–2005 package; 1,009 PDF pages. Running headers dated June 2001, A5U procedure identifiers. The copy omits its title/model-year cover. The owner accepted it as the tier-1 source for NB 2002 (BP-Z3) on 2026-10-23; it claims no coverage of 2001, later years or Mazdaspeed. A 2026-10-22 census finds the same 1719 running header on all 1,009 pages across 84 section files. Normalized extracted text exactly matches the archived 2002 samples at PDF pages 268 (timing belt), 526 (front brake), 925 (interior trim) and 931 (lighting). This supports a likely 2002 base-edition identity, but does not establish every page revision, regional applicability or a 2001–2005 coverage range. See docs/NB2-MANUAL-IDENTIFICATION.md for evidence and remaining checks. Reviewed HVAC pages corroborate the existing DENSO OIL9 records."
      }
    }
  ],
  "jobs": [],
  "system": "body",
  "component": "combined-audit-2026-10",
  "componentName": "Factory door switch and driver-input checks",
  "sequence_diagrams": [],
  "url": "https://miatatorque.com/spec/door-lock-switch-resistance-continuity-2003-2004/"
}
```