# Dynamic chamber gasket orientation (2003)

Canonical URL: https://miatatorque.com/spec/dynamic-chamber-gasket-orientation-2003/

Applicability: NB 2003 (BP-Z3)

Confidence: fsm

Factory dynamic chamber gasket: convex side faces the intake manifold.

Always confirm against your factory manual. Match every restriction and follow all stages and procedure notes. Disputed claims must not be automatically resolved. The complete record below preserves every printed unit, source claim and procedure.

```json
{
  "id": "dynamic-chamber-gasket-orientation-2003",
  "name": "Dynamic chamber gasket orientation (2003)",
  "aliases": [],
  "applies_to": [
    {
      "gen": "NB",
      "years": [
        2003,
        2003
      ],
      "engines": [
        "BP-Z3"
      ]
    }
  ],
  "kind": "non-torque",
  "value_text": "Factory dynamic chamber gasket: convex side faces the intake manifold.",
  "procedure": {
    "notes": "Disconnect the negative battery cable and service the intake only with the engine and intake cool. Drain and refill coolant as directed by the complete factory intake-air removal/installation procedure. Use a new gasket between the upper dynamic chamber and intake manifold as marked in the exploded view. Its convex face points toward the intake manifold, away from the dynamic chamber."
  },
  "confidence": "fsm",
  "sources": [
    {
      "source": "fsm-2003",
      "page": "Intake Air System Removal/Installation (PDF pp.675–677)",
      "as_printed": "Install the dynamic chamber gasket with the convex side of the gasket facing the intake manifold side.",
      "verified_years": [
        2003,
        2003
      ],
      "document": {
        "id": "fsm-2003",
        "tier": 1,
        "title": "2003 Mazda MX-5 Miata Workshop Manual (electronic manual capture)",
        "covers": [
          {
            "gen": "NB",
            "years": [
              2003,
              2003
            ],
            "engines": [
              "BP-Z3"
            ]
          }
        ],
        "note": "Normally aspirated BP procedures audited; turbo procedures are covered separately."
      }
    }
  ],
  "jobs": [],
  "system": "fuel-intake",
  "component": "release-validation-2003-2026-11",
  "componentName": "Factory service specifications (2003)",
  "sequence_diagrams": [],
  "url": "https://miatatorque.com/spec/dynamic-chamber-gasket-orientation-2003/"
}
```