# EVAP canister-to-purge isolated vacuum retention (2004)

Canonical URL: https://miatatorque.com/spec/evap-canister-to-purge-vacuum-hold-2004/

Applicability: NB 2004 (BP-Z3)

Confidence: fsm

Apply 3.3 kPa {25 mmHg, 1.0 inHg} vacuum to the disconnected hose; hold for at least 2 min.

Always confirm against your factory manual. Match every restriction and follow all stages and procedure notes. Disputed claims must not be automatically resolved. The complete record below preserves every printed unit, source claim and procedure.

```json
{
  "id": "evap-canister-to-purge-vacuum-hold-2004",
  "name": "EVAP canister-to-purge isolated vacuum retention (2004)",
  "aliases": [],
  "applies_to": [
    {
      "gen": "NB",
      "years": [
        2004,
        2004
      ],
      "engines": [
        "BP-Z3"
      ]
    }
  ],
  "kind": "non-torque",
  "value_text": "Apply 3.3 kPa {25 mmHg, 1.0 inHg} vacuum to the disconnected hose; hold for at least 2 min.",
  "procedure": {
    "notes": "P0455 isolated purge solenoid valve-side hose test, after checking the filler cap, purge valve and leak-detection pump and following the factory diagnostic sequence. Disconnect the purge solenoid valve-side vacuum hose at the charcoal canister and connect the vacuum pump to the disconnected hose, toward the purge solenoid valve; this does not apply the test vacuum to the canister port. Apply only the printed vacuum and check retention for at least two minutes. If it fails, follow the factory hose-connection and component-isolation branches to locate the leak; a failed check alone does not identify the component to replace. Reconnect all disconnected connectors and complete the factory evaporative leak inspection and after-repair procedure. This is separate from the other side’s vacuum and from positive-pressure or whole-system testing."
  },
  "confidence": "fsm",
  "sources": [
    {
      "source": "fsm-2004",
      "page": "DTC P0455, isolated purge solenoid valve-side leak test and restoration (PDF pp.334–337; test p.336)",
      "as_printed": "Disconnect purge solenoid\nvalve side vacuum hose at\ncharcoal canister.\nApply vacuum 3.3 kPa {25\nmmHg, 1.0 inHg} to\ndisconnected vacuum hose\nusing vacuum pump.\nDoes vacuum hold for\nminimum of 2 min?",
      "verified_years": [
        2004,
        2004
      ],
      "document": {
        "id": "fsm-2004",
        "tier": 1,
        "title": "2004 Mazda MX-5 Miata Workshop Manual (electronic manual capture)",
        "covers": [
          {
            "gen": "NB",
            "years": [
              2004,
              2004
            ],
            "engines": [
              "BP-Z3"
            ]
          }
        ],
        "note": "Normally aspirated BP procedures audited; turbo procedures are covered separately."
      }
    }
  ],
  "jobs": [],
  "system": "fuel-intake",
  "component": "release-validation-2004-2026-11",
  "componentName": "Factory fuel and emission service specifications (2004)",
  "sequence_diagrams": [],
  "url": "https://miatatorque.com/spec/evap-canister-to-purge-vacuum-hold-2004/"
}
```