# Factory S46A24LS battery charging-current limits (1990–1993)

Canonical URL: https://miatatorque.com/spec/factory-battery-charging-current-limits-1992/

Applicability: NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.; NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.

Confidence: fsm

Slow charge: under 3 A; quick charge: maximum 20 A.

Always confirm against your factory manual. Match every restriction and follow all stages and procedure notes. Disputed claims must not be automatically resolved. The complete record below preserves every printed unit, source claim and procedure.

```json
{
  "id": "factory-battery-charging-current-limits-1992",
  "name": "Factory S46A24LS battery charging-current limits (1990–1993)",
  "aliases": [],
  "applies_to": [
    {
      "gen": "NA",
      "years": [
        1992,
        1993
      ],
      "engines": [
        "B6"
      ],
      "note": "1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed."
    },
    {
      "gen": "NA",
      "years": [
        1990,
        1991
      ],
      "engines": [
        "B6"
      ],
      "note": "1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed."
    }
  ],
  "kind": "non-torque",
  "value_text": "Slow charge: under 3 A; quick charge: maximum 20 A.",
  "procedure": {
    "notes": "These limits apply to the original S46A24LS battery with its vent manifold, not an unspecified replacement battery. Stop the engine and switch off accessories. Remove the cover and disconnect the battery cables, negative first and reconnect it last. Do not remove vent caps; follow the charger instructions to prevent overcharging. Measure battery voltage before selecting charging current and duration. The factory uses a voltage-dependent current/time chart, so the maximum current is not permission to charge for an arbitrary duration; no single charging time is specified by this record."
  },
  "confidence": "fsm",
  "sources": [
    {
      "source": "fsm-1992",
      "page": "G–9 (PDF p. 305)",
      "as_printed": "Battery S46A24LS\nSlow charge (A) Under 3\nQuick charge (A) Max. 20",
      "verified_years": [
        1992,
        1992
      ],
      "document": {
        "id": "fsm-1992",
        "tier": 1,
        "title": "1992 Mazda MX-5 Miata Workshop Manual",
        "part_number": "1271-10-91G (9999-95-0428-92)",
        "covers": [
          {
            "gen": "NA",
            "years": [
              1992,
              1992
            ],
            "engines": [
              "B6"
            ]
          }
        ],
        "note": "Cover identifies model year 1992; the download folder name is not evidence for 1993."
      }
    },
    {
      "source": "fsm-1990",
      "page": "G–9 (PDF p. 293)",
      "as_printed": "Battery / Slow charge (A) / Quick charge (A)\nS46A24L(S) / Under 3 / Max. 20",
      "verified_years": [
        1990,
        1990
      ],
      "note": "Visually checked against the original 1990 factory page, including printed units and component/test context.",
      "document": {
        "id": "fsm-1990",
        "tier": 1,
        "title": "1990 Mazda MX-5 Miata Workshop Manual",
        "part_number": "1193-10-89C",
        "covers": [
          {
            "gen": "NA",
            "years": [
              1990,
              1990
            ],
            "engines": [
              "B6"
            ]
          }
        ],
        "url": "https://archive.org/details/1990-mazda-mx-5-miata-workshop-manual_202411"
      }
    }
  ],
  "jobs": [],
  "system": "ignition-electrical",
  "component": "combined-audit-2026-10",
  "componentName": "Factory early electrical diagnostic settings",
  "sequence_diagrams": [],
  "url": "https://miatatorque.com/spec/factory-battery-charging-current-limits-1992/"
}
```