# Factory battery voltage and five-hour capacity (1990–1993)

Canonical URL: https://miatatorque.com/spec/factory-battery-rating-1992/

Applicability: NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.; NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.

Confidence: fsm

12 V, negative ground; S46A24L(S), 32 Ah at the 5-hour rate

Always confirm against your factory manual. Match every restriction and follow all stages and procedure notes. Disputed claims must not be automatically resolved. The complete record below preserves every printed unit, source claim and procedure.

```json
{
  "id": "factory-battery-rating-1992",
  "name": "Factory battery voltage and five-hour capacity (1990–1993)",
  "aliases": [],
  "applies_to": [
    {
      "gen": "NA",
      "years": [
        1992,
        1993
      ],
      "engines": [
        "B6"
      ],
      "note": "1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed."
    },
    {
      "gen": "NA",
      "years": [
        1990,
        1991
      ],
      "engines": [
        "B6"
      ],
      "note": "1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed."
    }
  ],
  "kind": "non-torque",
  "value_text": "12 V, negative ground; S46A24L(S), 32 Ah at the 5-hour rate",
  "procedure": {
    "notes": "Identification rating of the original maintenance-free factory battery. The 32 Ah capacity is explicitly at the five-hour rate. This is not a cold-cranking-amp rating, charging-voltage target, load-test voltage or replacement fitment guide."
  },
  "confidence": "fsm",
  "sources": [
    {
      "source": "fsm-1992",
      "page": "TD–7 — Engine Electrical System, Battery (PDF p. 1049)",
      "as_printed": "Voltage V 12, Negative ground\nType and capacity (5-hour rate) S46A24L(S) (32Ah) Maintenance-free",
      "verified_years": [
        1992,
        1992
      ],
      "document": {
        "id": "fsm-1992",
        "tier": 1,
        "title": "1992 Mazda MX-5 Miata Workshop Manual",
        "part_number": "1271-10-91G (9999-95-0428-92)",
        "covers": [
          {
            "gen": "NA",
            "years": [
              1992,
              1992
            ],
            "engines": [
              "B6"
            ]
          }
        ],
        "note": "Cover identifies model year 1992; the download folder name is not evidence for 1993."
      }
    },
    {
      "source": "fsm-1990",
      "page": "TD–7 (PDF p. 793)",
      "as_printed": "Battery\nVoltage V 12, Negative ground\nType and capacity (5-hour rate) S46A24L(S) (32Ah) Maintenance-free",
      "verified_years": [
        1990,
        1990
      ],
      "note": "Visually checked against the original 1990 factory page, including printed units and component/test context.",
      "document": {
        "id": "fsm-1990",
        "tier": 1,
        "title": "1990 Mazda MX-5 Miata Workshop Manual",
        "part_number": "1193-10-89C",
        "covers": [
          {
            "gen": "NA",
            "years": [
              1990,
              1990
            ],
            "engines": [
              "B6"
            ]
          }
        ],
        "url": "https://archive.org/details/1990-mazda-mx-5-miata-workshop-manual_202411"
      }
    }
  ],
  "jobs": [],
  "system": "ignition-electrical",
  "component": "combined-audit-2026-10",
  "componentName": "Factory ignition-electrical service audit",
  "sequence_diagrams": [],
  "url": "https://miatatorque.com/spec/factory-battery-rating-1992/"
}
```