# Fuel-filler vent cut valve airflow inspection (1999–2000)

Canonical URL: https://miatatorque.com/spec/fuel-filler-vent-cut-valve-airflow-1999/

Applicability: NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.

Confidence: fsm

Cap installed: air passes from rollover-valve connection to TPCV connection. Cap removed and internal filler-port lever depressed: air must not pass along that same path.

Always confirm against your factory manual. Match every restriction and follow all stages and procedure notes. Disputed claims must not be automatically resolved. The complete record below preserves every printed unit, source claim and procedure.

```json
{
  "id": "fuel-filler-vent-cut-valve-airflow-1999",
  "name": "Fuel-filler vent cut valve airflow inspection (1999–2000)",
  "aliases": [],
  "applies_to": [
    {
      "gen": "NB",
      "years": [
        1999,
        2000
      ],
      "engines": [
        "BP-4W"
      ],
      "note": "1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed."
    }
  ],
  "kind": "non-torque",
  "value_text": "Cap installed: air passes from rollover-valve connection to TPCV connection. Cap removed and internal filler-port lever depressed: air must not pass along that same path.",
  "procedure": {
    "notes": "Install the proper factory fuel-filler cap tightly; an incorrect or loose cap can prevent correct operation. With the cap on, verify airflow from the rollover-valve connection (a) to the tank-pressure-control-valve (TPCV) connection (b). These are the small filler-pipe connections C and D in the factory routing view, identified by their physical destinations; they are not the large tank breather and joint hoses A/B. Remove the cap and depress the lever inside the fuel-filler port; in this state air must not pass along the same (a)-to-(b) path. If the cap-on test blocks airflow or the cap-off/lever-depressed test passes airflow, replace the complete fuel-filler pipe component. Follow the factory fuel-system access precautions and keep fuel away from ignition sources. The page specifies no test pressure."
  },
  "confidence": "fsm",
  "sources": [
    {
      "source": "fsm-1999",
      "page": "01–14–20 (PDF p.253)",
      "as_printed": "Verify that air goes through from (a) to (b) with the\nfuel-filler cap on.\nWhile depressing the lever in the fuel-filler port,\nverify that air does not go through from (a) to (b).",
      "verified_years": [
        1999,
        1999
      ],
      "document": {
        "id": "fsm-1999",
        "tier": 1,
        "title": "1999 Mazda MX-5 Miata Workshop Manual",
        "covers": [
          {
            "gen": "NB",
            "years": [
              1999,
              2000
            ],
            "engines": [
              "BP-4W"
            ]
          }
        ],
        "url": "https://www.mellens.net/mazda/Mazda-Miata-1999-2001.pdf"
      }
    }
  ],
  "jobs": [],
  "system": "fuel-intake",
  "component": "release-validation-1999-2026-11",
  "componentName": "Factory service specifications (1999)",
  "sequence_diagrams": [],
  "url": "https://miatatorque.com/spec/fuel-filler-vent-cut-valve-airflow-1999/"
}
```