# Generator terminal voltage inspection (2005, non-turbo)

Canonical URL: https://miatatorque.com/spec/generator-terminal-voltage-2005/

Applicability: NB 2005 (BP-Z3)

Confidence: fsm

Ignition ON: B = battery voltage, P below 1 V, D approximately 0 V. At idle, 20°C (68°F): B 13–15 V; P approximately 3–8 V; D increases with electrical load.

Always confirm against your factory manual. Match every restriction and follow all stages and procedure notes. Disputed claims must not be automatically resolved. The complete record below preserves every printed unit, source claim and procedure.

```json
{
  "id": "generator-terminal-voltage-2005",
  "name": "Generator terminal voltage inspection (2005, non-turbo)",
  "aliases": [],
  "applies_to": [
    {
      "gen": "NB",
      "years": [
        2005,
        2005
      ],
      "engines": [
        "BP-Z3"
      ]
    }
  ],
  "kind": "non-torque",
  "value_text": "Ignition ON: B = battery voltage, P below 1 V, D approximately 0 V. At idle, 20°C (68°F): B 13–15 V; P approximately 3–8 V; D increases with electrical load.",
  "procedure": {
    "notes": "Start with a fully charged battery, correct belt deflection/tension and all electrical loads off. Compare each named generator terminal with the ignition-ON or idling column. For D at idle, turn on headlights, blower motor and rear window defroster and verify voltage increases. B is generator output, while P and D are the small control-connector terminals; these readings are not interchangeable. Preparation is 2005 PDF 897; the contact view and table are on PDF 898. Identify the two small control terminals from the harness connector’s wire-entry side with its locking tab uppermost: D is on the left and P on the right. Keep that viewpoint when identifying the wires for measurement; the source connector drawing is a harness-side view."
  },
  "confidence": "fsm",
  "sources": [
    {
      "source": "fsm-2005",
      "page": "Generator Inspection — voltage (PDF pp.897–898)",
      "as_printed": "Verify that the battery is fully charged.\nVerify that the drive belt deflection/tension is within the specification.\nTurn off all electrical loads.\nStandard voltage\nTerminal Ignition switch ON (V) Idle (V) [20 °C {68 °F}]\nB B+ 13—15\nP Below 1 Approx. 3—8\nD Approx. 0 *\nTurn the following electrical loads on and verify that the voltage reading increases.\nHeadlights\nBlower motor\nRear window defroster",
      "verified_years": [
        2005,
        2005
      ],
      "document": {
        "id": "fsm-2005",
        "tier": 1,
        "title": "2005 Mazda MX-5 Miata Workshop Manual (electronic manual capture)",
        "covers": [
          {
            "gen": "NB",
            "years": [
              2005,
              2005
            ],
            "engines": [
              "BP-Z3"
            ]
          },
          {
            "gen": "NB",
            "years": [
              2005,
              2005
            ],
            "engines": [
              "BP-Z3-TURBO"
            ],
            "trans": [
              "6MT"
            ]
          }
        ]
      }
    }
  ],
  "jobs": [],
  "system": "engine",
  "component": "release-validation-2005-2026-11",
  "componentName": "Factory source validation additions (2005)",
  "sequence_diagrams": [],
  "url": "https://miatatorque.com/spec/generator-terminal-voltage-2005/"
}
```
