# Heater blower-resistor isolated continuity (1990–1993)

Canonical URL: https://miatatorque.com/spec/heater-blower-resistor-isolated-continuity-1992/

Applicability: NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.; NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.

Confidence: fsm

Disconnected resistor assembly: continuity from its common single-contact blue/red lead to each four-contact connector tap — blue/yellow (Lo), blue/green (Me), blue/red (Mh) and blue/white (Hi).

Always confirm against your factory manual. Match every restriction and follow all stages and procedure notes. Disputed claims must not be automatically resolved. The complete record below preserves every printed unit, source claim and procedure.

```json
{
  "id": "heater-blower-resistor-isolated-continuity-1992",
  "name": "Heater blower-resistor isolated continuity (1990–1993)",
  "aliases": [],
  "applies_to": [
    {
      "gen": "NA",
      "years": [
        1992,
        1993
      ],
      "engines": [
        "B6"
      ],
      "note": "1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed."
    },
    {
      "gen": "NA",
      "years": [
        1990,
        1991
      ],
      "engines": [
        "B6"
      ],
      "note": "1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed."
    }
  ],
  "kind": "non-torque",
  "value_text": "Disconnected resistor assembly: continuity from its common single-contact blue/red lead to each four-contact connector tap — blue/yellow (Lo), blue/green (Me), blue/red (Mh) and blue/white (Hi).",
  "procedure": {
    "notes": "Turn ignition OFF and disconnect both resistor plugs before measuring only the resistor component. The common is the separate single-contact lead, not the blue/red tap in the four-contact plug. Identify tap paths by their original wire colors. Use the factory ×1,000 ohmmeter range; the table gives continuity only and no numerical resistance for individual speed sections. Replace the resistor assembly if a specified path is open."
  },
  "confidence": "fsm",
  "sources": [
    {
      "source": "fsm-1992",
      "page": "U–22 (PDF p. 1014)",
      "as_printed": "Check for continuity between terminals of the resistor assembly.\nC—Lo Yes\nC—Me Yes\nC—Mh Yes\nC—Hi Yes\nSet the ohmmeter to the x1,000 range.",
      "verified_years": [
        1992,
        1992
      ],
      "document": {
        "id": "fsm-1992",
        "tier": 1,
        "title": "1992 Mazda MX-5 Miata Workshop Manual",
        "part_number": "1271-10-91G (9999-95-0428-92)",
        "covers": [
          {
            "gen": "NA",
            "years": [
              1992,
              1992
            ],
            "engines": [
              "B6"
            ]
          }
        ],
        "note": "Cover identifies model year 1992; the download folder name is not evidence for 1993."
      }
    },
    {
      "source": "fsm-1992",
      "page": "U–4 (PDF p. 996)",
      "as_printed": "RESISTOR ASSEMBLY\nL/Y\nL/R\nL/W\nL/G",
      "verified_years": [
        1992,
        1992
      ],
      "document": {
        "id": "fsm-1992",
        "tier": 1,
        "title": "1992 Mazda MX-5 Miata Workshop Manual",
        "part_number": "1271-10-91G (9999-95-0428-92)",
        "covers": [
          {
            "gen": "NA",
            "years": [
              1992,
              1992
            ],
            "engines": [
              "B6"
            ]
          }
        ],
        "note": "Cover identifies model year 1992; the download folder name is not evidence for 1993."
      }
    },
    {
      "source": "fsm-1990",
      "page": "U–22 (PDF p. 765)",
      "as_printed": "Check for continuity between terminals of the resistor assembly.\nC—Lo Yes\nC—Me Yes\nC—Mh Yes\nC—Hi Yes\nSet the ohmmeter to the x1,000 range.",
      "verified_years": [
        1990,
        1990
      ],
      "note": "Visually checked against the original 1990 factory page, including printed units and component/test context.",
      "document": {
        "id": "fsm-1990",
        "tier": 1,
        "title": "1990 Mazda MX-5 Miata Workshop Manual",
        "part_number": "1193-10-89C",
        "covers": [
          {
            "gen": "NA",
            "years": [
              1990,
              1990
            ],
            "engines": [
              "B6"
            ]
          }
        ],
        "url": "https://archive.org/details/1990-mazda-mx-5-miata-workshop-manual_202411"
      }
    },
    {
      "source": "fsm-1990",
      "page": "U–4 (PDF p. 747)",
      "as_printed": "RESISTOR ASSEMBLY\nL/Y\nL/R\nL/W\nL/G",
      "verified_years": [
        1990,
        1990
      ],
      "note": "Visually checked against the original 1990 factory page, including printed units and component/test context.",
      "document": {
        "id": "fsm-1990",
        "tier": 1,
        "title": "1990 Mazda MX-5 Miata Workshop Manual",
        "part_number": "1193-10-89C",
        "covers": [
          {
            "gen": "NA",
            "years": [
              1990,
              1990
            ],
            "engines": [
              "B6"
            ]
          }
        ],
        "url": "https://archive.org/details/1990-mazda-mx-5-miata-workshop-manual_202411"
      }
    }
  ],
  "jobs": [],
  "system": "hvac",
  "component": "combined-audit-2026-10",
  "componentName": "Factory early HVAC diagnostic and cable settings",
  "sequence_diagrams": [],