# Heater blower-switch connected voltage checks (1992–1993)

Canonical URL: https://miatatorque.com/spec/heater-blower-switch-connected-voltage-1992/

Applicability: NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.

Confidence: fsm

Ignition ON: fourth blower speed → black (B) switch ground wire 0 V; blower and A/C OFF → battery voltage on blue/white, blue/red, blue/green and blue/yellow at the connected blower switch.

Always confirm against your factory manual. Match every restriction and follow all stages and procedure notes. Disputed claims must not be automatically resolved. The complete record below preserves every printed unit, source claim and procedure.

```json
{
  "id": "heater-blower-switch-connected-voltage-1992",
  "name": "Heater blower-switch connected voltage checks (1992–1993)",
  "aliases": [],
  "applies_to": [
    {
      "gen": "NA",
      "years": [
        1992,
        1993
      ],
      "engines": [
        "B6"
      ],
      "note": "1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed."
    }
  ],
  "kind": "non-torque",
  "value_text": "Ignition ON: fourth blower speed → black (B) switch ground wire 0 V; blower and A/C OFF → battery voltage on blue/white, blue/red, blue/green and blue/yellow at the connected blower switch.",
  "procedure": {
    "notes": "Measure relative to body ground, with the original switch, motor and resistor connectors connected. Check the black ground at fourth speed first: battery voltage there indicates a ground-path fault. Then turn both blower and A/C OFF and measure the four named colored wires individually. A zero feed at this stage directs repair between resistor and switch; with all four at battery voltage the flow directs switch replacement. These powered checks are separate from the isolated switch-continuity test."
  },
  "confidence": "fsm",
  "sources": [
    {
      "source": "fsm-1992",
      "page": "U–8 (PDF p. 1000)",
      "as_printed": "Turn the ignition switch ON.\nTurn the blower switch to the fourth position.\nMeasure the voltage at terminal-wire (B) of the blower switch connector.\n(B) 0V\nTurn the ignition switch ON.\nTurn the blower switch and A/C switch OFF.\nMeasure the voltage at the terminal-wires of the blower switch connector.\nVB: Battery voltage\n(L/W) VB\n(L/R) VB\n(L/G) VB\n(L/Y) VB",
      "verified_years": [
        1992,
        1992
      ],
      "document": {
        "id": "fsm-1992",
        "tier": 1,
        "title": "1992 Mazda MX-5 Miata Workshop Manual",
        "part_number": "1271-10-91G (9999-95-0428-92)",
        "covers": [
          {
            "gen": "NA",
            "years": [
              1992,
              1992
            ],
            "engines": [
              "B6"
            ]
          }
        ],
        "note": "Cover identifies model year 1992; the download folder name is not evidence for 1993."
      }
    }
  ],
  "jobs": [],
  "system": "hvac",
  "component": "combined-audit-2026-10",
  "componentName": "Factory early HVAC diagnostic and cable settings",
  "sequence_diagrams": [],
  "url": "https://miatatorque.com/spec/heater-blower-switch-connected-voltage-1992/"
}
```