# Factory high-tension lead resistance per length (1990–1993)

Canonical URL: https://miatatorque.com/spec/high-tension-lead-resistance-per-length-1992/

Applicability: NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.; NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.

Confidence: fsm

16 kΩ per 1 m (3.28 ft).

Always confirm against your factory manual. Match every restriction and follow all stages and procedure notes. Disputed claims must not be automatically resolved. The complete record below preserves every printed unit, source claim and procedure.

```json
{
  "id": "high-tension-lead-resistance-per-length-1992",
  "name": "Factory high-tension lead resistance per length (1990–1993)",
  "aliases": [],
  "applies_to": [
    {
      "gen": "NA",
      "years": [
        1992,
        1993
      ],
      "engines": [
        "B6"
      ],
      "note": "1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed."
    },
    {
      "gen": "NA",
      "years": [
        1990,
        1991
      ],
      "engines": [
        "B6"
      ],
      "note": "1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed."
    }
  ],
  "kind": "non-torque",
  "value_text": "16 kΩ per 1 m (3.28 ft).",
  "procedure": {
    "notes": "With each factory spark-plug lead disconnected, measure end-to-end resistance using an ohmmeter. The source specifies resistance per unit lead length, not the same total resistance for every cylinder’s lead. This is separate from ignition-coil winding resistance and does not establish a limit for aftermarket lead construction."
  },
  "confidence": "fsm",
  "sources": [
    {
      "source": "fsm-1992",
      "page": "G–20 (PDF p. 316)",
      "as_printed": "Resistance: 16 kΩ per 1 m (3.28 ft)",
      "verified_years": [
        1992,
        1992
      ],
      "document": {
        "id": "fsm-1992",
        "tier": 1,
        "title": "1992 Mazda MX-5 Miata Workshop Manual",
        "part_number": "1271-10-91G (9999-95-0428-92)",
        "covers": [
          {
            "gen": "NA",
            "years": [
              1992,
              1992
            ],
            "engines": [
              "B6"
            ]
          }
        ],
        "note": "Cover identifies model year 1992; the download folder name is not evidence for 1993."
      }
    },
    {
      "source": "fsm-1990",
      "page": "G–22 (PDF p. 306)",
      "as_printed": "Resistance: 16 kΩ per 1 m (3.28 ft)",
      "verified_years": [
        1990,
        1990
      ],
      "note": "Visually checked against the original 1990 factory page, including printed units and component/test context.",
      "document": {
        "id": "fsm-1990",
        "tier": 1,
        "title": "1990 Mazda MX-5 Miata Workshop Manual",
        "part_number": "1193-10-89C",
        "covers": [
          {
            "gen": "NA",
            "years": [
              1990,
              1990
            ],
            "engines": [
              "B6"
            ]
          }
        ],
        "url": "https://archive.org/details/1990-mazda-mx-5-miata-workshop-manual_202411"
      }
    },
    {
      "source": "fsm-1992",
      "page": "F–57, F–61 (PDF pp. 211, 215)",
      "as_printed": "Resistance: 16 kΩ per 1m (3.28 ft)",
      "verified_years": [
        1992,
        1992
      ],
      "document": {
        "id": "fsm-1992",
        "tier": 1,
        "title": "1992 Mazda MX-5 Miata Workshop Manual",
        "part_number": "1271-10-91G (9999-95-0428-92)",
        "covers": [
          {
            "gen": "NA",
            "years": [
              1992,
              1992
            ],
            "engines": [
              "B6"
            ]
          }
        ],
        "note": "Cover identifies model year 1992; the download folder name is not evidence for 1993."
      }
    }
  ],
  "jobs": [],
  "system": "ignition-electrical",
  "component": "combined-audit-2026-10",
  "componentName": "Factory early electrical diagnostic settings",
  "sequence_diagrams": [],
  "url": "https://miatatorque.com/spec/high-tension-lead-resistance-per-length-1992/"
}
```