# Airflow defroster-mode switch continuity (2004–2005)

Canonical URL: https://miatatorque.com/spec/hvac-airflow-defroster-switch-continuity-2005/

Applicability: NB 2005 (BP-Z3/BP-Z3-TURBO); NB 2004 (BP-Z3-TURBO) — 2005 Mazdaspeed applicability is supported by the cited 2005 factory pages; 2004 Mazdaspeed follows the owner-approved 2004–2005 Mazdaspeed carry-over policy. No 2004 Mazdaspeed revision verification is claimed.

Confidence: fsm

Across the two contacts A–B: VENT, BI-LEVEL and HEAT open; HEAT/DEF and DEFROSTER continuity.

Always confirm against your factory manual. Match every restriction and follow all stages and procedure notes. Disputed claims must not be automatically resolved. The complete record below preserves every printed unit, source claim and procedure.

```json
{
  "id": "hvac-airflow-defroster-switch-continuity-2005",
  "name": "Airflow defroster-mode switch continuity (2004–2005)",
  "aliases": [],
  "applies_to": [
    {
      "gen": "NB",
      "years": [
        2005,
        2005
      ],
      "engines": [
        "BP-Z3",
        "BP-Z3-TURBO"
      ]
    },
    {
      "gen": "NB",
      "years": [
        2004,
        2004
      ],
      "engines": [
        "BP-Z3-TURBO"
      ],
      "note": "2005 Mazdaspeed applicability is supported by the cited 2005 factory pages; 2004 Mazdaspeed follows the owner-approved 2004–2005 Mazdaspeed carry-over policy. No 2004 Mazdaspeed revision verification is claimed."
    }
  ],
  "kind": "non-torque",
  "value_text": "Across the two contacts A–B: VENT, BI-LEVEL and HEAT open; HEAT/DEF and DEFROSTER continuity.",
  "procedure": {
    "notes": "Use the airflow-mode defroster switch on the removed and unplugged original climate-control unit. This is the switch operated by airflow mode selection. Measure between its only two component contacts; the terminal-face view, with the locating projections above, has B left and A right. Meter polarity does not affect this passive continuity check. Test each of the five stated mode positions separately. Replace the defroster switch if incorrect."
  },
  "confidence": "fsm",
  "sources": [
    {
      "source": "fsm-2005",
      "page": "Climate Control Unit Inspection — Defroster Switch (PDF pp.1793–1794)",
      "as_printed": "Inspect for continuity between the defroster switch terminals using a tester.\nMode switch position\nVENT, BI-LEVEL, HEAT\nHEAT/DEF, DEFROSTER",
      "verified_years": [
        2005,
        2005
      ],
      "document": {
        "id": "fsm-2005",
        "tier": 1,
        "title": "2005 Mazda MX-5 Miata Workshop Manual (electronic manual capture)",
        "covers": [
          {
            "gen": "NB",
            "years": [
              2005,
              2005
            ],
            "engines": [
              "BP-Z3"
            ]
          },
          {
            "gen": "NB",
            "years": [
              2005,
              2005
            ],
            "engines": [
              "BP-Z3-TURBO"
            ],
            "trans": [
              "6MT"
            ]
          }
        ]
      }
    }
  ],
  "jobs": [],
  "system": "hvac",
  "component": "release-validation-2005-2026-11",
  "componentName": "Factory HVAC service references (2005)",
  "sequence_diagrams": [],