# Heater temperature blend control-wire adjustment (1990–1991)

Canonical URL: https://miatatorque.com/spec/hvac-temperature-blend-wire-adjustment-1990/

Applicability: NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.

Confidence: fsm

Set the temperature blend lever to MAX-HOT; connect and clamp its wire with the heater-unit shutter lever all the way to the right in the factory illustration.

Always confirm against your factory manual. Match every restriction and follow all stages and procedure notes. Disputed claims must not be automatically resolved. The complete record below preserves every printed unit, source claim and procedure.

```json
{
  "id": "hvac-temperature-blend-wire-adjustment-1990",
  "name": "Heater temperature blend control-wire adjustment (1990–1991)",
  "short_name": "Heater temperature wire setting (1990–1991)",
  "aliases": [],
  "applies_to": [
    {
      "gen": "NA",
      "years": [
        1990,
        1991
      ],
      "engines": [
        "B6"
      ],
      "note": "1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed."
    }
  ],
  "kind": "non-torque",
  "value_text": "Set the temperature blend lever to MAX-HOT; connect and clamp its wire with the heater-unit shutter lever all the way to the right in the factory illustration.",
  "procedure": {
    "notes": "For reconnecting the factory heater temperature blend control wire after dashboard service. Select MAX-HOT at the control panel, then connect and clamp the wire at the shutter-lever position shown as MAXIMUM HOT in the factory S–52 illustration. Right refers to that illustrated lever view. After installation move the temperature blend control through its full HOT-to-COLD stroke and verify secure wire attachment and full travel. This is the temperature wire, separate from the airflow-mode and REC–FRESH wires. Do not transplant later rotary-control cable settings."
  },
  "confidence": "fsm",
  "sources": [
    {
      "source": "fsm-1990",
      "page": "S–52 (PDF p.559)",
      "as_printed": "Temperature blend wire\nSet the temperature blend lever to MAX-HOT position.\nConnect and clamp the wire with the shutter lever on the heater unit all the way to the right.\nAfter installation, move the temperature blend lever to be sure the wire is securely attached, and that it moves the full stroke from HOT to COLD.",
      "verified_years": [
        1990,
        1990
      ],
      "document": {
        "id": "fsm-1990",
        "tier": 1,
        "title": "1990 Mazda MX-5 Miata Workshop Manual",
        "part_number": "1193-10-89C",
        "covers": [
          {
            "gen": "NA",
            "years": [
              1990,
              1990
            ],
            "engines": [
              "B6"
            ]
          }
        ],
        "url": "https://archive.org/details/1990-mazda-mx-5-miata-workshop-manual_202411"
      }
    },
    {
      "source": "fsm-1990",
      "page": "U–25 (PDF p.768)",
      "as_printed": "Set the temperature blend lever to maximum hot position.\nConnect and clamp the wire with the shutter lever on the\nheater unit all the way to the right.\nAfter installation, move the temperature blend le-\nver to be sure the wire is securely attached and that\nit moves the full stroke from HOT to COLD.",
      "verified_years": [
        1990,
        1990
      ],
      "document": {
        "id": "fsm-1990",
        "tier": 1,
        "title": "1990 Mazda MX-5 Miata Workshop Manual",
        "part_number": "1193-10-89C",
        "covers": [
          {
            "gen": "NA",
            "years": [
              1990,
              1990
            ],
            "engines": [
              "B6"
            ]
          }
        ],
        "url": "https://archive.org/details/1990-mazda-mx-5-miata-workshop-manual_202411"
      }
    }
  ],
  "jobs": [],
  "system": "hvac",
  "component": "release-validation-2026-11",
  "componentName": "Factory air conditioning pressure inspection (1990)",
  "sequence_diagrams": [],
  "url": "https://miatatorque.com/spec/hvac-temperature-blend-wire-adjustment-1990/"
}
```