# Ignition coil case insulation resistance (1990–1993)

Canonical URL: https://miatatorque.com/spec/ignition-coil-case-insulation-1992/

Applicability: NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.; NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.

Confidence: fsm

10 MΩ minimum, using a 500 V megger tester

Always confirm against your factory manual. Match every restriction and follow all stages and procedure notes. Disputed claims must not be automatically resolved. The complete record below preserves every printed unit, source claim and procedure.

```json
{
  "id": "ignition-coil-case-insulation-1992",
  "name": "Ignition coil case insulation resistance (1990–1993)",
  "aliases": [],
  "applies_to": [
    {
      "gen": "NA",
      "years": [
        1992,
        1993
      ],
      "engines": [
        "B6"
      ],
      "note": "1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed."
    },
    {
      "gen": "NA",
      "years": [
        1990,
        1991
      ],
      "engines": [
        "B6"
      ],
      "note": "1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed."
    }
  ],
  "kind": "non-torque",
  "value_text": "10 MΩ minimum, using a 500 V megger tester",
  "procedure": {
    "notes": "Isolate the ignition coil from vehicle wiring before measuring between its primary terminal and case. This factory test specifies a 500 V insulation tester; it is not the ordinary ohmmeter winding-resistance check."
  },
  "confidence": "fsm",
  "sources": [
    {
      "source": "fsm-1992",
      "page": "G–19 (PDF p. 315)",
      "as_printed": "Use a 500V megger tester to measure the insulation resistance between the primary terminal and the coil case.\nResistance : 10 MΩ min.",
      "verified_years": [
        1992,
        1992
      ],
      "document": {
        "id": "fsm-1992",
        "tier": 1,
        "title": "1992 Mazda MX-5 Miata Workshop Manual",
        "part_number": "1271-10-91G (9999-95-0428-92)",
        "covers": [
          {
            "gen": "NA",
            "years": [
              1992,
              1992
            ],
            "engines": [
              "B6"
            ]
          }
        ],
        "note": "Cover identifies model year 1992; the download folder name is not evidence for 1993."
      }
    },
    {
      "source": "fsm-1990",
      "page": "G–21 (PDF p. 305)",
      "as_printed": "Use a 500V megger tester to measure the insulation resistance between the primary terminal and the coil case.\nResistance : 10 MΩ min.",
      "verified_years": [
        1990,
        1990
      ],
      "note": "Visually checked against the original 1990 factory page, including printed units and component/test context.",
      "document": {
        "id": "fsm-1990",
        "tier": 1,
        "title": "1990 Mazda MX-5 Miata Workshop Manual",
        "part_number": "1193-10-89C",
        "covers": [
          {
            "gen": "NA",
            "years": [
              1990,
              1990
            ],
            "engines": [
              "B6"
            ]
          }
        ],
        "url": "https://archive.org/details/1990-mazda-mx-5-miata-workshop-manual_202411"
      }
    }
  ],
  "jobs": [],
  "system": "ignition-electrical",
  "component": "combined-audit-2026-10",
  "componentName": "Factory ignition-electrical service audit",
  "sequence_diagrams": [],