# PCM A/C relay and pressure-switch scan references (1999–2000)

Canonical URL: https://miatatorque.com/spec/pcm-ac-relay-switch-scan-reference-1999/

Applicability: NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.

Confidence: fsm

A/C RLY: A/C operating, ON; ignition ON, OFF. A/C SW: refrigerant pressure switch and fan switch ON, ON; refrigerant pressure switch OFF, OFF.

Always confirm against your factory manual. Match every restriction and follow all stages and procedure notes. Disputed claims must not be automatically resolved. The complete record below preserves every printed unit, source claim and procedure.

```json
{
  "id": "pcm-ac-relay-switch-scan-reference-1999",
  "name": "PCM A/C relay and pressure-switch scan references (1999–2000)",
  "aliases": [],
  "applies_to": [
    {
      "gen": "NB",
      "years": [
        1999,
        2000
      ],
      "engines": [
        "BP-4W"
      ],
      "note": "1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed."
    }
  ],
  "kind": "non-torque",
  "value_text": "A/C RLY: A/C operating, ON; ignition ON, OFF. A/C SW: refrigerant pressure switch and fan switch ON, ON; refrigerant pressure switch OFF, OFF.",
  "procedure": {
    "notes": "Connect NGS tester to DLC-2, turn ignition ON, select PID/DATA MONITOR AND RECORD and press TRIGGER, select the named PID and press START. Observe each printed condition separately. These are PCM scan-tool reference readings, not direct connector voltages or commands to energize a component. If incorrect, follow the factory action column and associated inspection. Observe relay output A/C RLY separately from the A/C SW refrigerant-pressure-switch input. A/C RLY fault follow-up checks RPM, TP V, ECT V, A/C SW and the A/C relay; A/C SW directs refrigerant-pressure-switch inspection. The factory requires the output-device simulation test after PID monitoring; the reference states do not establish a substitute powered relay test."
  },
  "confidence": "fsm",
  "sources": [
    {
      "source": "fsm-1999",
      "page": "01–40–4 (PDF p.293)",
      "as_printed": "A/C RLY (A/C relay)\nA/C operating: ON\nIgnition switch ON: OFF\nA/C SW (Refrigerant\npressure switch)\nRefrigerant pressure switch and fan\nswitch ON: ON\nRefrigerant pressure switch OFF:\nOFF",
      "verified_years": [
        1999,
        1999
      ],
      "document": {
        "id": "fsm-1999",
        "tier": 1,
        "title": "1999 Mazda MX-5 Miata Workshop Manual",
        "covers": [
          {
            "gen": "NB",
            "years": [
              1999,
              2000
            ],
            "engines": [
              "BP-4W"
            ]
          }
        ],
        "url": "https://www.mellens.net/mazda/Mazda-Miata-1999-2001.pdf"
      }
    }
  ],
  "jobs": [],
  "system": "ignition-electrical",
  "component": "release-validation-1999-2026-11",
  "componentName": "Factory sensor inspections (1999)",
  "sequence_diagrams": [],
  "url": "https://miatatorque.com/spec/pcm-ac-relay-switch-scan-reference-1999/"
}
```