# PCM front oxygen-sensor scan reference (1999–2000)

Canonical URL: https://miatatorque.com/spec/pcm-front-oxygen-sensor-scan-reference-1999/

Applicability: NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.

Confidence: fsm

FHO2S: ignition ON, 0—1.0 V; after warm-up, 0—1.0 V; acceleration, 0.5—1.0 V; deceleration, 0—0.5 V. FHO2SH heater reference: ON.

Always confirm against your factory manual. Match every restriction and follow all stages and procedure notes. Disputed claims must not be automatically resolved. The complete record below preserves every printed unit, source claim and procedure.

```json
{
  "id": "pcm-front-oxygen-sensor-scan-reference-1999",
  "name": "PCM front oxygen-sensor scan reference (1999–2000)",
  "aliases": [],
  "applies_to": [
    {
      "gen": "NB",
      "years": [
        1999,
        2000
      ],
      "engines": [
        "BP-4W"
      ],
      "note": "1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed."
    }
  ],
  "kind": "non-torque",
  "value_text": "FHO2S: ignition ON, 0—1.0 V; after warm-up, 0—1.0 V; acceleration, 0.5—1.0 V; deceleration, 0—0.5 V. FHO2SH heater reference: ON.",
  "procedure": {
    "notes": "Read this as a PCM scan-tool reference, not a direct connector-probing specification. Connect the NGS tester to DLC-2, turn ignition ON, select PID/DATA MONITOR AND RECORD and press TRIGGER, select the named PID and press START. Observe each stated condition separately. If incorrect, follow the factory action column and associated component inspection rather than replacing a component solely from a reference reading. Select FHO2S for the front heated oxygen-sensor signal and FHO2SH for its heater state. Read each table condition independently; the heater row is labeled Always:ON within this PID inspection. These are reported diagnostic references, not an external sensor-bias test, an instruction to apply voltage or a claim that the sensor must continuously output one fixed voltage. For incorrect readings follow the factory sensor/heater inspection and associated ECT V/MAF V checks."
  },
  "confidence": "fsm",
  "sources": [
    {
      "source": "fsm-1999",
      "page": "01–40–4 (PDF p. 293)",
      "as_printed": "Connect the NGS tester to the DLC-2.\nTurn the ignition switch on.\nSelect the appropriate PID on the NGS display\nand press START.\nMeasure the PID value.",
      "verified_years": [
        1999,
        1999
      ],
      "document": {
        "id": "fsm-1999",
        "tier": 1,
        "title": "1999 Mazda MX-5 Miata Workshop Manual",
        "covers": [
          {
            "gen": "NB",
            "years": [
              1999,
              2000
            ],
            "engines": [
              "BP-4W"
            ]
          }
        ],
        "url": "https://www.mellens.net/mazda/Mazda-Miata-1999-2001.pdf"
      }
    },
    {
      "source": "fsm-1999",
      "page": "01–40–5 (PDF p. 294)",
      "as_printed": "FHO2S (Heated oxygen\nsensor (Front))\nV\nIgnition switch ON: 0—1.0 V\nAfter warms up: 0—1.0 V\nAcceleration: 0.5—1.0 V\nDeceleration: 0—0.5 V\nFHO2SH (Heated oxygen\nsensor heater (Front))\nON/OFF\nAlways: ON",
      "verified_years": [
        1999,
        1999
      ],
      "document": {
        "id": "fsm-1999",
        "tier": 1,
        "title": "1999 Mazda MX-5 Miata Workshop Manual",
        "covers": [
          {
            "gen": "NB",
            "years": [
              1999,
              2000
            ],
            "engines": [
              "BP-4W"
            ]
          }
        ],
        "url": "https://www.mellens.net/mazda/Mazda-Miata-1999-2001.pdf"
      }
    }
  ],
  "jobs": [],
  "system": "ignition-electrical",
  "component": "release-validation-1999-2026-11",
  "componentName": "Factory sensor inspections (1999)",
  "sequence_diagrams": [],
  "url": "https://miatatorque.com/spec/pcm-front-oxygen-sensor-scan-reference-1999/"
}
```