# PCM generator field and output-voltage scan references (1999–2000)

Canonical URL: https://miatatorque.com/spec/pcm-generator-field-voltage-scan-reference-1999/

Applicability: NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.

Confidence: fsm

ALTF: ignition ON, 0%; idle, 0—100%; with generator operating, duty rises when electrical loads turn ON. ALT T V: ignition ON, 0 V; idle, B+ +1 V.

Always confirm against your factory manual. Match every restriction and follow all stages and procedure notes. Disputed claims must not be automatically resolved. The complete record below preserves every printed unit, source claim and procedure.

```json
{
  "id": "pcm-generator-field-voltage-scan-reference-1999",
  "name": "PCM generator field and output-voltage scan references (1999–2000)",
  "aliases": [],
  "applies_to": [
    {
      "gen": "NB",
      "years": [
        1999,
        2000
      ],
      "engines": [
        "BP-4W"
      ],
      "note": "1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed."
    }
  ],
  "kind": "non-torque",
  "value_text": "ALTF: ignition ON, 0%; idle, 0—100%; with generator operating, duty rises when electrical loads turn ON. ALT T V: ignition ON, 0 V; idle, B+ +1 V.",
  "procedure": {
    "notes": "Connect NGS tester to DLC-2, turn ignition ON, select PID/DATA MONITOR AND RECORD and press TRIGGER, select the named PID and press START. Observe each printed condition separately. These are PCM scan-tool reference readings, not direct connector voltages or commands to energize a component. If incorrect, follow the factory action column and associated inspection. Read the generator field duty ALTF and the separately reported output voltage ALT T V. B+ is battery positive voltage; retain the printed relative idle reference B+ +1 V rather than replacing it with a fixed charging range. If incorrect, check IAT, IAT V, RPM, B+, B+2 and the companion generator PID and perform the factory generator inspection. The duty reference is not a minimum generator output-current specification."
  },
  "confidence": "fsm",
  "sources": [
    {
      "source": "fsm-1999",
      "page": "01–40–4 (PDF p.293)",
      "as_printed": "ALTF (Generator field coil\ncontrol duty value)\nIgnition switch ON: 0%\nIdle: 0—100%\nGenerator operating → E/L ON:\nDuty value rise\nALT T V (Generator output\nvoltage)\nIgnition switch ON: 0 V\nIdle: B+ +1 V",
      "verified_years": [
        1999,
        1999
      ],
      "document": {
        "id": "fsm-1999",
        "tier": 1,
        "title": "1999 Mazda MX-5 Miata Workshop Manual",
        "covers": [
          {
            "gen": "NB",
            "years": [
              1999,
              2000
            ],
            "engines": [
              "BP-4W"
            ]
          }
        ],
        "url": "https://www.mellens.net/mazda/Mazda-Miata-1999-2001.pdf"
      }
    }
  ],
  "jobs": [],
  "system": "ignition-electrical",
  "component": "release-validation-1999-2026-11",
  "componentName": "Factory sensor inspections (1999)",
  "sequence_diagrams": [],
  "url": "https://miatatorque.com/spec/pcm-generator-field-voltage-scan-reference-1999/"
}
```
