# Purge solenoid airflow test (1999–2000)

Canonical URL: https://miatatorque.com/spec/purge-solenoid-airflow-test-1999/

Applicability: NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.

Confidence: fsm

Unpowered: terminal A–B continuity, no airflow between ports A and B. Terminal A battery positive/B ground: airflow between ports A and B.

Always confirm against your factory manual. Match every restriction and follow all stages and procedure notes. Disputed claims must not be automatically resolved. The complete record below preserves every printed unit, source claim and procedure.

```json
{
  "id": "purge-solenoid-airflow-test-1999",
  "name": "Purge solenoid airflow test (1999–2000)",
  "aliases": [],
  "applies_to": [
    {
      "gen": "NB",
      "years": [
        1999,
        2000
      ],
      "engines": [
        "BP-4W"
      ],
      "note": "1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed."
    }
  ],
  "kind": "non-torque",
  "value_text": "Unpowered: terminal A–B continuity, no airflow between ports A and B. Terminal A battery positive/B ground: airflow between ports A and B.",
  "procedure": {
    "notes": "Perform only when directed after the factory purge-control simulation test. Disconnect battery negative and remove the valve using the factory procedure. Check unpowered coil continuity A–B and the unpowered/powered pneumatic table. For the powered row apply battery positive to electrical A and ground to electrical B. The valve connector depicts B left, A right. In the side view the pneumatic ports point upward: B is the left port, A the right port nearer the valve body. Do not substitute electrical letters for pneumatic ports. Replace if incorrect; if the bench test passes but simulation fails, inspect hoses and specified circuits. Reinstall in reverse order and seat both vacuum and evaporative hoses against their stoppers."
  },
  "confidence": "fsm",
  "sources": [
    {
      "source": "fsm-1999",
      "page": "01–16–8–9 (PDF pp. 264–265)",
      "as_printed": "Perform the following test only when directed.\nInspect airflow between the ports under the\nfollowing conditions.",
      "verified_years": [
        1999,
        1999
      ],
      "document": {
        "id": "fsm-1999",
        "tier": 1,
        "title": "1999 Mazda MX-5 Miata Workshop Manual",
        "covers": [
          {
            "gen": "NB",
            "years": [
              1999,
              2000
            ],
            "engines": [
              "BP-4W"
            ]
          }
        ],
        "url": "https://www.mellens.net/mazda/Mazda-Miata-1999-2001.pdf"
      }
    }
  ],
  "jobs": [],
  "system": "fuel-intake",
  "component": "release-validation-1999-2026-11",
  "componentName": "Factory service specifications (1999)",
  "sequence_diagrams": [],
  "url": "https://miatatorque.com/spec/purge-solenoid-airflow-test-1999/"
}
```