# Starter no-load bench test (2001–2004)

Canonical URL: https://miatatorque.com/spec/starter-no-load-test-2003-2004/

Applicability: NB 2003 (BP-Z3); NB 2004 (BP-Z3); NB 2001–2002 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 carry-over policy, with hardware, test setup and connector perspective compared against publication 1719-1U-01G. Its existing owner-accepted 2002 source coverage is unchanged; 2001 is carry-over, not an independently verified year.

Confidence: fsm

11 V; current below 90 A

Always confirm against your factory manual. Match every restriction and follow all stages and procedure notes. Disputed claims must not be automatically resolved. The complete record below preserves every printed unit, source claim and procedure.

```json
{
  "id": "starter-no-load-test-2003-2004",
  "name": "Starter no-load bench test (2001–2004)",
  "aliases": [],
  "applies_to": [
    {
      "gen": "NB",
      "years": [
        2003,
        2003
      ],
      "engines": [
        "BP-Z3"
      ]
    },
    {
      "gen": "NB",
      "years": [
        2004,
        2004
      ],
      "engines": [
        "BP-Z3"
      ]
    },
    {
      "gen": "NB",
      "years": [
        2001,
        2002
      ],
      "engines": [
        "BP-Z3"
      ],
      "note": "2001–2002 applicability follows the owner-approved early-NB2 carry-over policy, with hardware, test setup and connector perspective compared against publication 1719-1U-01G. Its existing owner-accepted 2002 source coverage is unchanged; 2001 is carry-over, not an independently verified year."
    }
  ],
  "kind": "non-torque",
  "value_text": "11 V; current below 90 A",
  "procedure": {
    "notes": "With fully charged battery and removed starter, connect battery positive through ammeter to B, switched positive to S, and battery negative to starter body; connect voltmeter across supply/body. Starter must turn smoothly without mechanical load; measure voltage/current while operating. Bench wiring is on 2003 PDF 798 / 2004 PDF 827. This is not engine cranking current or the 1992 0.95 kW starter test."
  },
  "confidence": "fsm",
  "sources": [
    {
      "source": "fsm-2003",
      "page": "Starter no-load bench test (2003–2004) (PDF p. 799)",
      "as_printed": "Specification\nVoltage (V) 11\nCurrent (A) Below 90",
      "verified_years": [
        2003,
        2003
      ],
      "document": {
        "id": "fsm-2003",
        "tier": 1,
        "title": "2003 Mazda MX-5 Miata Workshop Manual (electronic manual capture)",
        "covers": [
          {
            "gen": "NB",
            "years": [
              2003,
              2003
            ],
            "engines": [
              "BP-Z3"
            ]
          }
        ],
        "note": "Normally aspirated BP procedures audited; turbo procedures are covered separately."
      }
    },
    {
      "source": "fsm-2004",
      "page": "Starter no-load bench test (2003–2004) (PDF p. 828)",
      "as_printed": "Specification\nVoltage (V) 11\nCurrent (A) Below 90",
      "verified_years": [
        2004,
        2004
      ],
      "document": {
        "id": "fsm-2004",
        "tier": 1,
        "title": "2004 Mazda MX-5 Miata Workshop Manual (electronic manual capture)",
        "covers": [
          {
            "gen": "NB",
            "years": [
              2004,
              2004
            ],
            "engines": [
              "BP-Z3"
            ]
          }
        ],
        "note": "Normally aspirated BP procedures audited; turbo procedures are covered separately."
      }
    },
    {
      "source": "workshop-1719-1u-01g",
      "page": "01–19–3 (PDF p. 357)",
      "as_printed": "Operate the starter and verify that it turns smoothly.\nMeasure the voltage and current while the starter is operating.\nSpecification\nVoltage (V)\n11\nCurrent (A)\nBelow 90",
      "note": "Visually checked against the original factory page; printed units and component/test context retained. Source edition/market limitations remain as documented; no additional verified years assigned.",
      "document": {
        "id": "workshop-1719-1u-01g",
        "tier": 1,
        "title": "Mazda MX-5 Workshop Manual, publication 1719-1U-01G (2002 base edition)",
        "part_number": "1719-1U-01G",
        "covers": [
          {
            "gen": "NB",
            "years": [
              2002,
              2002
            ],
            "engines": [
              "BP-Z3"
            ]
          }
        ],
        "note": "Factory typeset document supplied in the purchased 2001–2005 package; 1,009 PDF pages. Running headers dated June 2001, A5U procedure identifiers. The copy omits its title/model-year cover. The owner accepted it as the tier-1 source for NB 2002 (BP-Z3) on 2026-10-23; it claims no coverage of 2001, later years or Mazdaspeed. A 2026-10-22 census finds the same 1719 running header on all 1,009 pages across 84 section files. Normalized extracted text exactly matches the archived 2002 samples at PDF pages 268 (timing belt), 526 (front brake), 925 (interior trim) and 931 (lighting). This supports a likely 2002 base-edition identity, but does not establish every page revision, regional applicability or a 2001–2005 coverage range. See docs/NB2-MANUAL-IDENTIFICATION.md for evidence and remaining checks. Reviewed HVAC pages corroborate the existing DENSO OIL9 records."
      }
    },
    {
      "source": "fsm-2003",
      "page": "Starter Inspection — no-load bench setup (PDF pp.798–799)",
      "as_printed": "Verify that the battery is fully charged.\nConnect the starter, battery, voltmeter, and ammeter as shown.\nOperate the starter and verify that it turns smoothly.\nMeasure the voltage and current while the starter is operating.",
      "verified_years": [
        2003,
        2003
      ],
      "note": "Original schematic confirms ammeter in battery-positive supply to B, switched branch to S, body return to battery negative and voltmeter across supply/body. Existing11V/below90A test preserved; no engine-cranking or magnetic-switch-return hookup substituted.",
      "document": {
        "id": "fsm-2003",
        "tier": 1,
        "title": "2003 Mazda MX-5 Miata Workshop Manual (electronic manual capture)",
        "covers": [
          {
            "gen": "NB",
            "years": [
              2003,
              2003
            ],
            "engines": [
              "BP-Z3"
            ]
          }
        ],
        "note": "Normally aspirated BP procedures audited; turbo procedures are covered separately."
      }
    },
    {
      "source": "fsm-2004",
      "page": "Starter Inspection — no-load bench setup (PDF pp.827–828)",
      "as_printed": "Verify that the battery is fully charged.\nConnect the starter, battery, voltmeter, and ammeter as shown.\nOperate the starter and verify that it turns smoothly.\nMeasure the voltage and current while the starter is operating.",
      "verified_years": [
        2004,
        2004
      ],
      "note": "Original827schematic confirms seriesammeter in batterypositive toB,switchedpositiveS,bodyreturnnegative,voltmeteracrosssupply/body. Full current11V/below90A removedstarter test retained;notenginecranking ormagnetic returntest.",
      "document": {
        "id": "fsm-2004",
        "tier": 1,
        "title": "2004 Mazda MX-5 Miata Workshop Manual (electronic manual capture)",
        "covers": [
          {
            "gen": "NB",
            "years": [
              2004,
              2004
            ],
            "engines": [
              "BP-Z3"
            ]
          }
        ],
        "note": "Normally aspirated BP procedures audited; turbo procedures are covered separately."
      }
    }
  ],
  "jobs": [],
  "system": "ignition-electrical",
  "component": "combined-audit-2026-10",
  "componentName": "Factory ignition-electrical service audit",
  "sequence_diagrams": [],
  "url": "https://miatatorque.com/spec/starter-no-load-test-2003-2004/"
}
```
