# Tank pressure control valve airflow test (1999–2000)

Canonical URL: https://miatatorque.com/spec/tpcv-airflow-test-1999/

Applicability: NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.

Confidence: fsm

Unpowered, pressure applied to port A: 0—+0.20 kPa {0—+1.47 mmHg, 0—+0.06 inHg}: no airflow; above +0.98 kPa {+7.36 mmHg, +0.29 inHg}: airflow; below −0.98 kPa {−7.36 mmHg, −0.29 inHg}: airflow. Powered terminal A positive/B ground: smooth airflow.

Always confirm against your factory manual. Match every restriction and follow all stages and procedure notes. Disputed claims must not be automatically resolved. The complete record below preserves every printed unit, source claim and procedure.

```json
{
  "id": "tpcv-airflow-test-1999",
  "name": "Tank pressure control valve airflow test (1999–2000)",
  "aliases": [],
  "applies_to": [
    {
      "gen": "NB",
      "years": [
        1999,
        2000
      ],
      "engines": [
        "BP-4W"
      ],
      "note": "1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed."
    }
  ],
  "kind": "non-torque",
  "value_text": "Unpowered, pressure applied to port A: 0—+0.20 kPa {0—+1.47 mmHg, 0—+0.06 inHg}: no airflow; above +0.98 kPa {+7.36 mmHg, +0.29 inHg}: airflow; below −0.98 kPa {−7.36 mmHg, −0.29 inHg}: airflow. Powered terminal A positive/B ground: smooth airflow.",
  "procedure": {
    "notes": "Perform only when directed after the factory evaporative-emission control simulation test. Disconnect battery negative and remove the TPCV. Apply pressure to pneumatic port A, the straight tube end on the right in the factory valve view. Use the three printed unpowered pressure/airflow conditions; do not infer limits for the unlisted intervals or a numerical flow rate from the graph. Then apply battery positive to electrical terminal A and ground to electrical B as drawn (B left, A right in the depicted valve connector), apply pressure to pneumatic port A and verify smooth airflow. Electrical terminal A and pneumatic port A are separate features. Replace the TPCV if incorrect. If the bench test passes but simulation fails, follow the factory hose-routing, kink/leak and supply/ground wiring diagnosis. Reconnect battery negative afterward."
  },
  "confidence": "fsm",
  "sources": [
    {
      "source": "fsm-1999",
      "page": "01–16–6 (PDF p. 262)",
      "as_printed": "Pressure kPa {mmHg, inHg}\nBetween 0— +0.20 {0— +1.47, 0— +0.06}\nNo\nAbove +0.98 {+7.36, +0.29}\nYes\nBelow −0.98 {−7.36, −0.29}\nYes\nApply battery positive voltage to the valve\nconnector terminal A and apply pressure to port A,\nand verify that air flows smoothly.",
      "verified_years": [
        1999,
        1999
      ],
      "document": {
        "id": "fsm-1999",
        "tier": 1,
        "title": "1999 Mazda MX-5 Miata Workshop Manual",
        "covers": [
          {
            "gen": "NB",
            "years": [
              1999,
              2000
            ],
            "engines": [
              "BP-4W"
            ]
          }
        ],
        "url": "https://www.mellens.net/mazda/Mazda-Miata-1999-2001.pdf"
      }
    }
  ],
  "jobs": [],
  "system": "fuel-intake",
  "component": "release-validation-1999-2026-11",
  "componentName": "Factory service specifications (1999)",
  "sequence_diagrams": [],
  "url": "https://miatatorque.com/spec/tpcv-airflow-test-1999/"
}
```