# VICS shutter actuator vacuum test (1999–2000)

Canonical URL: https://miatatorque.com/spec/vics-shutter-actuator-vacuum-test-1999/

Applicability: NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.

Confidence: fsm

Above −1.3 kPa {−10 mmHg, −0.4 inHg}: not pulled; −1.3—−4.0 kPa {−10—−30 mmHg, −0.4—−1.1 inHg}: starts moving; below −26 kPa {−190 mmHg, −7.5 inHg}: fully pulled.

Always confirm against your factory manual. Match every restriction and follow all stages and procedure notes. Disputed claims must not be automatically resolved. The complete record below preserves every printed unit, source claim and procedure.

```json
{
  "id": "vics-shutter-actuator-vacuum-test-1999",
  "name": "VICS shutter actuator vacuum test (1999–2000)",
  "aliases": [],
  "applies_to": [
    {
      "gen": "NB",
      "years": [
        1999,
        2000
      ],
      "engines": [
        "BP-4W"
      ],
      "note": "1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed."
    }
  ],
  "kind": "non-torque",
  "value_text": "Above −1.3 kPa {−10 mmHg, −0.4 inHg}: not pulled; −1.3—−4.0 kPa {−10—−30 mmHg, −0.4—−1.1 inHg}: starts moving; below −26 kPa {−190 mmHg, −7.5 inHg}: fully pulled.",
  "procedure": {
    "notes": "Perform the isolated actuator operation test only when directed after the factory VICS operation inspection. Disconnect the vacuum hose from the VICS shutter valve actuator, connect a vacuum pump directly to it and apply vacuum slowly while watching the actuator rod. Use the signed pressure ranges exactly as printed; the source gives no additional transition or travel specification between the start-to-move and fully-pulled rows. Replace the actuator if incorrect. If this test passes but simulation failed, inspect hose routing, kinks and leakage. This is a vacuum diaphragm rod test, separate from solenoid-port airflow and engine-speed switching."
  },
  "confidence": "fsm",
  "sources": [
    {
      "source": "fsm-1999",
      "page": "01–13–5 (PDF p. 231)",
      "as_printed": "Perform the following test only when directed.\nVacuum\nkPa {mmHg, inHg}\nRod movement\nAbove −1.3 {−10, −0.4} Not pulled\n−1.3—−4.0 {−10—−30, −0.4—−1.1} Start to move\nBelow −26 {−190, −7.5} Fully pulled",
      "verified_years": [
        1999,
        1999
      ],
      "document": {
        "id": "fsm-1999",
        "tier": 1,
        "title": "1999 Mazda MX-5 Miata Workshop Manual",
        "covers": [
          {
            "gen": "NB",
            "years": [
              1999,
              2000
            ],
            "engines": [
              "BP-4W"
            ]
          }
        ],
        "url": "https://www.mellens.net/mazda/Mazda-Miata-1999-2001.pdf"
      }
    }
  ],
  "jobs": [],
  "system": "fuel-intake",
  "component": "release-validation-1999-2026-11",
  "componentName": "Factory service specifications (1999)",
  "sequence_diagrams": [],
  "url": "https://miatatorque.com/spec/vics-shutter-actuator-vacuum-test-1999/"
}
```
