# VTCS shutter actuator vacuum test (2001–2004)

Canonical URL: https://miatatorque.com/spec/vtcs-actuator-vacuum-test-2003-2004/

Applicability: NB 2003 (BP-Z3); NB 2004 (BP-Z3); NB 2001–2002 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 carry-over policy, with hardware, test setup and connector perspective compared against publication 1719-1U-01G. Its existing owner-accepted 2002 source coverage is unchanged; 2001 is carry-over, not an independently verified year.

Confidence: fsm

Starts moving at approximately −9.3 kPa {−69.8 mmHg, −2.7 inHg}; fully pulled below −34.7 kPa {−260 mmHg, −10.2 inHg}; not pulled above −6.7 kPa {−51 mmHg, −2.0 inHg}.

Always confirm against your factory manual. Match every restriction and follow all stages and procedure notes. Disputed claims must not be automatically resolved. The complete record below preserves every printed unit, source claim and procedure.

```json
{
  "id": "vtcs-actuator-vacuum-test-2003-2004",
  "name": "VTCS shutter actuator vacuum test (2001–2004)",
  "aliases": [],
  "applies_to": [
    {
      "gen": "NB",
      "years": [
        2003,
        2003
      ],
      "engines": [
        "BP-Z3"
      ]
    },
    {
      "gen": "NB",
      "years": [
        2004,
        2004
      ],
      "engines": [
        "BP-Z3"
      ]
    },
    {
      "gen": "NB",
      "years": [
        2001,
        2002
      ],
      "engines": [
        "BP-Z3"
      ],
      "note": "2001–2002 applicability follows the owner-approved early-NB2 carry-over policy, with hardware, test setup and connector perspective compared against publication 1719-1U-01G. Its existing owner-accepted 2002 source coverage is unchanged; 2001 is carry-over, not an independently verified year."
    }
  ],
  "kind": "non-torque",
  "value_text": "Starts moving at approximately −9.3 kPa {−69.8 mmHg, −2.7 inHg}; fully pulled below −34.7 kPa {−260 mmHg, −10.2 inHg}; not pulled above −6.7 kPa {−51 mmHg, −2.0 inHg}.",
  "procedure": {
    "notes": "When directed by the diagnostic procedure, disconnect the actuator vacuum hose and connect a hand vacuum pump directly to the actuator. Apply vacuum slowly and observe the actuator rod against the stated conditions. These are negative gauge pressures; below means more negative. Replace the actuator if movement fails this test. If this mechanical test passes but the simulation test fails, inspect vacuum-hose routing, kinks and leakage. No rod-travel distance is specified."
  },
  "confidence": "fsm",
  "sources": [
    {
      "source": "fsm-2003",
      "page": "VTCS Shutter Valve Actuator Inspection (PDF p. 673)",
      "as_printed": "Approx. –9.3 {–69.8, –2.7}\nBelow –34.7 {–260, –10.2}\nAbove –6.7 {–51, –2.0}",
      "verified_years": [
        2003,
        2003
      ],
      "document": {
        "id": "fsm-2003",
        "tier": 1,
        "title": "2003 Mazda MX-5 Miata Workshop Manual (electronic manual capture)",
        "covers": [
          {
            "gen": "NB",
            "years": [
              2003,
              2003
            ],
            "engines": [
              "BP-Z3"
            ]
          }
        ],
        "note": "Normally aspirated BP procedures audited; turbo procedures are covered separately."
      }
    },
    {
      "source": "fsm-2004",
      "page": "VTCS Shutter Valve Actuator Inspection (PDF p. 705)",
      "as_printed": "Approx. –9.3 {–69.8, –2.7}\nBelow –34.7 {–260, –10.2}\nAbove –6.7 {–51, –2.0}",
      "verified_years": [
        2004,
        2004
      ],
      "document": {
        "id": "fsm-2004",
        "tier": 1,
        "title": "2004 Mazda MX-5 Miata Workshop Manual (electronic manual capture)",
        "covers": [
          {
            "gen": "NB",
            "years": [
              2004,
              2004
            ],
            "engines": [
              "BP-Z3"
            ]
          }
        ],
        "note": "Normally aspirated BP procedures audited; turbo procedures are covered separately."
      }
    },
    {
      "source": "workshop-1719-1u-01g",
      "page": "01–13–7 (PDF p. 310)",
      "as_printed": "Vacuum kPa {mmHg, inHg}\nApprox. –9.3 {–69.8, –2.7}\nBelow –34.7 {–260, –10.2}\nAbove –6.7 {–51, –2.0}\nRod movement\nStart to move\nFully pulled\nNot pulled",
      "note": "Visually checked against the original factory page; printed units and component/test context retained. Source edition/market limitations remain as documented; no additional verified years assigned.",
      "document": {
        "id": "workshop-1719-1u-01g",
        "tier": 1,
        "title": "Mazda MX-5 Workshop Manual, publication 1719-1U-01G (2002 base edition)",
        "part_number": "1719-1U-01G",
        "covers": [
          {
            "gen": "NB",
            "years": [
              2002,
              2002
            ],
            "engines": [
              "BP-Z3"
            ]
          }
        ],
        "note": "Factory typeset document supplied in the purchased 2001–2005 package; 1,009 PDF pages. Running headers dated June 2001, A5U procedure identifiers. The copy omits its title/model-year cover. The owner accepted it as the tier-1 source for NB 2002 (BP-Z3) on 2026-10-23; it claims no coverage of 2001, later years or Mazdaspeed. A 2026-10-22 census finds the same 1719 running header on all 1,009 pages across 84 section files. Normalized extracted text exactly matches the archived 2002 samples at PDF pages 268 (timing belt), 526 (front brake), 925 (interior trim) and 931 (lighting). This supports a likely 2002 base-edition identity, but does not establish every page revision, regional applicability or a 2001–2005 coverage range. See docs/NB2-MANUAL-IDENTIFICATION.md for evidence and remaining checks. Reviewed HVAC pages corroborate the existing DENSO OIL9 records."
      }
    }
  ],
  "jobs": [],
  "system": "fuel-intake",
  "component": "combined-audit-2026-10",
  "componentName": "Factory fuel-intake service audit",
  "sequence_diagrams": [],
  "url": "https://miatatorque.com/spec/vtcs-actuator-vacuum-test-2003-2004/"
}
```