# Fuel & Intake · Miata Torque DB

Canonical URL: https://miatatorque.com/system/fuel-intake/

- [Home](https://miatatorque.com/)
- Fuel & Intake

#

Fuel & Intake

## Torque specs

### Air cleaner

[Air cleaner lower bracket bolt · NA 1990–1993 (B6)](https://miatatorque.com/spec/air-cleaner-lower-bracket-bolt/) 14–19 ft·lb / 19–25 N·m

[Air cleaner bracket bolt (intake duct side) · NA 1990–1993 (B6)](https://miatatorque.com/spec/air-cleaner-duct-bracket-bolt/) 69–95 in·lb / 7.8–11 N·m

[Mass airflow sensor mounting bolts (NB2) · NB 2001–2005 (BP-Z3)](https://miatatorque.com/spec/mass-airflow-sensor-mounting-bolts-nb2/) 70–95 in·lb / 7.9–10.7 N·m

[Air intake hose clamps (NB2) · NB 2001–2005 (BP-Z3)](https://miatatorque.com/spec/air-intake-hose-clamps-nb2/) 22–30 in·lb / 2.5–3.4 N·m

[Mazdaspeed mass airflow sensor mounting bolts (NB2) · NB 2004–2005 (BP-Z3-TURBO, 6MT)](https://miatatorque.com/spec/mazdaspeed-mass-airflow-sensor-mounting-bolts-nb2/) 70–95 in·lb / 7.8–10.8 N·m

[Mazdaspeed air intake hose clamps (NB2) · NB 2004–2005 (BP-Z3-TURBO, 6MT)](https://miatatorque.com/spec/mazdaspeed-air-intake-hose-clamps-nb2/) 23–30 in·lb / 2.5–3.4 N·m

### Early NB2 factory service checks

[Canister drain-cut valve mounting bolts — early NB2 · NB 2001–2005 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 carry-over policy, with hardware, test setup and connector perspective compared against publication 1719-1U-01G. Its existing owner-accepted 2002 source coverage is unchanged; 2001 is carry-over, not an independently verified year.](https://miatatorque.com/spec/canister-drain-cut-valve-mounting-bolts-early-nb2/) 70–104 in·lb / 7.9–11.7 N·m

### Emissions (EGR)

[EGR valve bolts · NB 1999–2000 (BP-4W)](https://miatatorque.com/spec/egr-valve-bolts/) 14–18 ft·lb / 19–25 N·m

[EGR pipe flare nut · NB 1999–2000 (BP-4W)](https://miatatorque.com/spec/egr-pipe-flare-nut/) 24–34 ft·lb / 32–47 N·m

[EGR pipe union at intake manifold (NB2) · NB 2001–2005 (BP-Z3)](https://miatatorque.com/spec/egr-pipe-union-at-intake-manifold-nb2/) 24–34 ft·lb / 32–47 N·m

[Mazdaspeed EGR pipe union at exhaust manifold (NB2) · NB 2004–2005 (BP-Z3-TURBO, 6MT)](https://miatatorque.com/spec/mazdaspeed-egr-pipe-union-at-exhaust-manifold-nb2/) 24–34 ft·lb / 32–47 N·m

[Mazdaspeed EGR pipe mounting bolts (NB2) · NB 2004–2005 (BP-Z3-TURBO, 6MT)](https://miatatorque.com/spec/mazdaspeed-egr-pipe-mounting-bolts-nb2/) 70–95 in·lb / 7.8–10.8 N·m

[Purge solenoid valve mounting nut (NB2) · NB 2001–2005 (BP-Z3); NB 2004–2005 (BP-Z3-TURBO)](https://miatatorque.com/spec/purge-solenoid-valve-mounting-nut-nb2/) 79–112 in·lb / 8.9–12.7 N·m

[EGR valve mounting bolts (NB2) · NB 2001–2005 (BP-Z3); NB 2004–2005 (BP-Z3-TURBO)](https://miatatorque.com/spec/egr-valve-mounting-bolts-nb2/) 14–18 ft·lb / 19–25 N·m

[EGR pipe union at exhaust manifold (NB2) · NB 2001–2005 (BP-Z3)](https://miatatorque.com/spec/egr-pipe-union-at-exhaust-manifold-nb2/) ≈24–35 ft·lb / 32–47 N·m

[EGR pipe mounting bolts (NB2) · NB 2001–2005 (BP-Z3)](https://miatatorque.com/spec/egr-pipe-mounting-bolts-nb2/) ≈70–95 in·lb / 7.9–10.7 N·m

### Fuel rail & injectors

[Fuel rail (delivery pipe) bolts · NA 1994–1997 (BP); NB 1999–2000 (BP-4W); NA 1990–1993 (B6)](https://miatatorque.com/spec/fuel-rail-bolts/) 14–18 ft·lb / 19–25 N·m

[Fuel pressure regulator bolts · NA 1994–1997 (BP); NA 1990–1993 (B6)](https://miatatorque.com/spec/fuel-pressure-regulator-bolts/) 70–95 in·lb / 7.9–10.7 N·m

[Fuel filter bracket bolt · NA 1994–1997 (BP); NB 1999–2000 (BP-4W); NA 1990–1993 (B6)](https://miatatorque.com/spec/fuel-filter-bracket-bolt/) 70–95 in·lb / 7.9–10.7 N·m

[Injector harness and bracket fasteners · NA 1990–1993 (B6)](https://miatatorque.com/spec/injector-harness-bracket-fasteners/) 69–95 in·lb / 7.8–11 N·m

[Fuel delivery rail mounting bolts (NB2) · NB 2001–2005 (BP-Z3); NB 2004–2005 (BP-Z3-TURBO)](https://miatatorque.com/spec/fuel-delivery-rail-mounting-bolts-nb2/) 14–18 ft·lb / 19–25 N·m

[Fuel filter bracket mounting bolt (NB2) · NB 2001–2005 (BP-Z3); NB 2004–2005 (BP-Z3-TURBO)](https://miatatorque.com/spec/fuel-filter-bracket-mounting-bolt-nb2/) 70–95 in·lb / 7.9–10.7 N·m

### Fuel tank & pump

[Fuel pump mounting screws · NB 1999–2000 (BP-4W)](https://miatatorque.com/spec/fuel-pump-screws/) 10–19 in·lb / 1.1–2.1 N·m

[Fuel tank bracket bolts · NB 1999–2000 (BP-4W)](https://miatatorque.com/spec/fuel-tank-strap-bolts/) 16–22 ft·lb / 22–30 N·m

[Fuel filler neck bracket bolt · NA 1990–1993 (B6)](https://miatatorque.com/spec/fuel-filler-neck-bracket-bolt/) 22–31 in·lb / 2.4–3.5 N·m

[Fuel pump lower mounting bracket screw (NB2) · NB 2004–2005 (BP-Z3); NB 2004–2005 (BP-Z3-TURBO)](https://miatatorque.com/spec/fuel-pump-lower-mounting-bracket-screw-nb2/) 25–37 in·lb / 2.8–4.2 N·m

[Fuel tank mounting bolts (NB2) · NB 2001–2005 (BP-Z3); NB 2004–2005 (BP-Z3-TURBO)](https://miatatorque.com/spec/fuel-tank-mounting-bolts-nb2/) 16–22 ft·lb / 22–30 N·m

[Fuel tank protector mounting nuts (NB2) · NB 2001–2005 (BP-Z3); NB 2004–2005 (BP-Z3-TURBO)](https://miatatorque.com/spec/fuel-tank-protector-mounting-nuts-nb2/) 79–112 in·lb / 8.9–12.7 N·m

[Fuel filler pipe upper mounting bolts (NB2) · NB 2001–2005 (BP-Z3); NB 2004–2005 (BP-Z3-TURBO)](https://miatatorque.com/spec/fuel-filler-pipe-upper-mounting-bolts-nb2/) 22–31 in·lb / 2.5–3.5 N·m

[Fuel filler pipe lower bracket bolt (NB2) · NB 2001–2005 (BP-Z3); NB 2004–2005 (BP-Z3-TURBO)](https://miatatorque.com/spec/fuel-filler-pipe-lower-bracket-bolt-nb2/) 79–112 in·lb / 8.9–12.7 N·m

[Fuel tank side bracket bolts (NB2) · NB 2001–2005 (BP-Z3); NB 2004–2005 (BP-Z3-TURBO)](https://miatatorque.com/spec/fuel-tank-side-bracket-bolts-nb2/) 70–104 in·lb / 7.9–11.7 N·m

[Fuel tank side bracket nut (NB2) · NB 2001–2005 (BP-Z3); NB 2004–2005 (BP-Z3-TURBO)](https://miatatorque.com/spec/fuel-tank-side-bracket-nut-nb2/) 79–112 in·lb / 8.9–12.7 N·m

[Fuel pump lower mounting bracket screw (2001–03) · NB 2001 (BP-Z3) — 2001 follows the 2002 (1719-1U-01G) manual, the nearest edition; no 2001 manual was checked.; NB 2002–2003 (BP-Z3)](https://miatatorque.com/spec/fuel-pump-lower-mounting-bracket-screw-2003/) 70–95 in·lb / 7.9–10.7 N·m

### Service measurements and fasteners

[Intake manifold bracket bolts (NA6) · NA 1990–1993 (B6) — Other years inferred from 1990 factory evidence.](https://miatatorque.com/spec/intake-manifold-bracket-bolts-na6/) 27–40 ft·lb / 36–54 N·m

### Intake manifold

[Intake manifold nuts and bolts · NA 1990–1997 (B6/BP)](https://miatatorque.com/spec/intake-manifold-nuts/) 14–19 ft·lb / 19–25 N·m

[Intake manifold bracket bolts (NA 1.8) · NA 1994–1997 (BP) — Other years inferred from 1994 factory evidence.](https://miatatorque.com/spec/intake-manifold-bracket-bolts/) 28–38 ft·lb / 38–51 N·m

[Intake manifold support bracket upper bolts (NB2) · NB 2001–2005 (BP-Z3); NB 2004–2005 (BP-Z3-TURBO)](https://miatatorque.com/spec/intake-manifold-support-bracket-upper-bolts-nb2/) 28–38 ft·lb / 38–51 N·m

[VTCS solenoid valve mounting nut (NB2) · NB 2001–2005 (BP-Z3); NB 2004–2005 (BP-Z3-TURBO)](https://miatatorque.com/spec/vtcs-solenoid-valve-mounting-nut-nb2/) 79–112 in·lb / 8.9–12.7 N·m

[VTCS shutter valve actuator mounting bolts (NB2) · NB 2001–2005 (BP-Z3); NB 2004–2005 (BP-Z3-TURBO)](https://miatatorque.com/spec/vtcs-shutter-valve-actuator-mounting-bolts-nb2/) 70–95 in·lb / 7.9–10.7 N·m

[Intake manifold to head nuts (NB2) · NB 2001–2005 (BP-Z3); NB 2004–2005 (BP-Z3-TURBO)](https://miatatorque.com/spec/intake-manifold-to-head-nuts-nb2/) ≈14–18 ft·lb / 19–25 N·m

[Intake manifold upper section bolts (NB2) · NB 2001–2005 (BP-Z3); NB 2004–2005 (BP-Z3-TURBO)](https://miatatorque.com/spec/intake-manifold-upper-section-bolts-nb2/) ≈14–18 ft·lb / 19–25 N·m

### Additional factory specifications

[Accelerator cable bracket bolts (NB1) · NB 1999–2000 (BP-4W) — 2000 applicability inferred from 1999 factory evidence within the NB1 year group.](https://miatatorque.com/spec/accelerator-cable-bracket-bolts-nb1/) 70–95 in·lb / 7.9–10.7 N·m

[Dynamic chamber bracket bolts (NB1) · NB 1999–2000 (BP-4W) — 2000 applicability inferred from 1999 factory evidence within the NB1 year group.](https://miatatorque.com/spec/dynamic-chamber-bracket-bolts-nb1/) 70–95 in·lb / 7.9–10.7 N·m

[EGR pipe flange bolts at dynamic chamber (NB1) · NB 1999–2000 (BP-4W) — 2000 applicability inferred from 1999 factory evidence within the NB1 year group.](https://miatatorque.com/spec/egr-pipe-flange-bolts-nb1/) 70–95 in·lb / 7.9–10.7 N·m

[Intake air hose clamps (NB1) · NB 1999–2000 (BP-4W) — 2000 applicability inferred from 1999 factory evidence within the NB1 year group.](https://miatatorque.com/spec/intake-air-hose-clamps-nb1/) 22–30 in·lb / 2.5–3.4 N·m

[Air cleaner mounting nuts (NB1) · NB 1999–2000 (BP-4W) — 2000 applicability inferred from 1999 factory evidence within the NB1 year group.](https://miatatorque.com/spec/air-cleaner-mounting-nuts-nb1/) 14–16 ft·lb / 19–22 N·m

[Fresh-air duct mounting bolt (NB1) · NB 1999–2000 (BP-4W) — 2000 applicability inferred from 1999 factory evidence within the NB1 year group.](https://miatatorque.com/spec/fresh-air-duct-bolt-nb1/) 70–104 in·lb / 7.9–11.7 N·m

[Mass air flow sensor mounting bolts (NB1) · NB 1999–2000 (BP-4W) — 2000 applicability inferred from 1999 factory evidence within the NB1 year group.](https://miatatorque.com/spec/mass-air-flow-sensor-bolts-nb1/) 70–95 in·lb / 7.9–10.7 N·m

[Dynamic chamber stay bolts — dynamic chamber side (NB1) · NB 1999–2000 (BP-4W) — 2000 applicability inferred from 1999 factory evidence within the NB1 year group.](https://miatatorque.com/spec/dynamic-chamber-stay-chamber-side-bolts-nb1/) 14–18 ft·lb / 19–25 N·m

[Dynamic chamber stay bolt — intake manifold side (NB1) · NB 1999–2000 (BP-4W) — 2000 applicability inferred from 1999 factory evidence within the NB1 year group.](https://miatatorque.com/spec/dynamic-chamber-stay-manifold-side-bolt-nb1/) 28–38 ft·lb / 38–51 N·m

[Fuel distributor bracket bolt (NB1) · NB 1999–2000 (BP-4W) — 2000 applicability inferred from 1999 factory evidence within the NB1 year group.](https://miatatorque.com/spec/fuel-distributor-bracket-bolt-nb1/) 70–95 in·lb / 7.9–10.7 N·m

[Pulsation damper No. 2 nuts (NB1) · NB 1999–2000 (BP-4W) — 2000 applicability inferred from 1999 factory evidence within the NB1 year group.](https://miatatorque.com/spec/pulsation-damper-number-2-nuts-nb1/) 70–95 in·lb / 7.9–10.7 N·m

[Pulsation damper No. 1 mounting bolt (NB1) · NB 1999–2000 (BP-4W) — 2000 applicability inferred from 1999 factory evidence within the NB1 year group.](https://miatatorque.com/spec/pulsation-damper-number-1-bolt-nb1/) 70–95 in·lb / 7.9–10.7 N·m

[Fuel tank service hole cover bolts (NB1) · NB 1999–2000 (BP-4W) — 2000 applicability inferred from 1999 factory evidence within the NB1 year group.](https://miatatorque.com/spec/fuel-tank-service-hole-cover-bolts-nb1/) 79–112 in·lb / 8.9–12.7 N·m

[Fuel tank insulator mounting nuts (NB1) · NB 1999–2000 (BP-4W) — 2000 applicability inferred from 1999 factory evidence within the NB1 year group.](https://miatatorque.com/spec/fuel-tank-insulator-nuts-nb1/) 79–112 in·lb / 8.9–12.7 N·m

[Charcoal canister mounting nuts (NB1) · NB 1999–2000 (BP-4W) — 2000 applicability inferred from 1999 factory evidence within the NB1 year group.](https://miatatorque.com/spec/charcoal-canister-mounting-nuts-nb1/) 79–112 in·lb / 8.9–12.7 N·m

[Fuel filler pipe upper mounting bolts (NB1) · NB 1999–2000 (BP-4W) — 2000 applicability inferred from 1999 factory evidence within the NB1 year group.](https://miatatorque.com/spec/fuel-filler-pipe-upper-bolts-nb1/) 22–31 in·lb / 2.5–3.5 N·m

[Fuel filler pipe lower mounting bolts (NB1) · NB 1999–2000 (BP-4W) — 2000 applicability inferred from 1999 factory evidence within the NB1 year group.](https://miatatorque.com/spec/fuel-filler-pipe-lower-bolts-nb1/) 79–112 in·lb / 8.9–12.7 N·m

[Fuel pipe dust cover bolts (NB1) · NB 1999–2000 (BP-4W) — 2000 applicability inferred from 1999 factory evidence within the NB1 year group.](https://miatatorque.com/spec/fuel-pipe-dust-cover-bolts-nb1/) 70–104 in·lb / 7.9–11.7 N·m

### Factory service specifications (1999)

[VICS shutter valve actuator mounting bolts (1999–2000) · NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.](https://miatatorque.com/spec/vics-shutter-actuator-bolts-1999/) 70–95 in·lb / 7.9–10.7 N·m

[VICS solenoid mounting nut (1999–2000) · NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.](https://miatatorque.com/spec/vics-solenoid-mounting-nut-1999/) 78–112 in·lb / 8.9–12.7 N·m

[Accelerator cable adjusting locknuts (1999–2000) · NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.](https://miatatorque.com/spec/accelerator-cable-adjusting-locknuts-1999/) 7–10 ft·lb / 9.8–14 N·m

[Fuel pump lower retaining bracket bolt (1999–2000) · NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.](https://miatatorque.com/spec/fuel-pump-lower-bracket-bolt-1999/) 70–95 in·lb / 7.9–10.7 N·m

[High-pressure fuel filter band clamp bolt (1999–2000) · NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.](https://miatatorque.com/spec/fuel-filter-band-clamp-bolt-1999/) 36–52 in·lb / 4.1–5.8 N·m

[Fuel tank rollover valve mounting bolts (1999–2000) · NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.](https://miatatorque.com/spec/rollover-valve-mounting-bolts-1999/) 10–19 in·lb / 1.1–2.1 N·m

[Canister drain-cut valve mounting bolts (1999–2000) · NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.](https://miatatorque.com/spec/canister-drain-cut-valve-mounting-bolts-1999/) 70–104 in·lb / 7.9–11.7 N·m

[Purge solenoid mounting nut (1999–2000) · NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.](https://miatatorque.com/spec/purge-solenoid-mounting-nut-1999/) 79–112 in·lb / 8.9–12.7 N·m

[Accelerator cable bulkhead mounting bolts (1999–2000) · NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.](https://miatatorque.com/spec/accelerator-cable-bulkhead-mounting-bolts-1999/) 70–95 in·lb / 7.9–10.7 N·m

### Additional 1994 service specifications

[Injector harness and bracket fasteners (NA 1.8) · NA 1994–1997 (BP) — 1995–1997 applicability inferred from 1994 within the year group.](https://miatatorque.com/spec/injector-harness-bracket-fasteners-na-bp/) 70–95 in·lb / 7.9–10.7 N·m

### Throttle body & idle control

[Throttle body bolts and nuts · NA 1994–1997 (BP); NB 1999–2000 (BP-4W); NA 1990–1993 (B6)](https://miatatorque.com/spec/throttle-body-bolts/) 14–18 ft·lb / 19–25 N·m

[Idle air control valve bolts · NB 1999–2000 (BP-4W)](https://miatatorque.com/spec/iac-valve-bolts/) 39–57 in·lb / 4.3–6.5 N·m

[Accelerator cable adjusting locknuts (NB2) · NB 2001–2005 (BP-Z3); NB 2004–2005 (BP-Z3-TURBO)](https://miatatorque.com/spec/accelerator-cable-adjusting-locknuts-nb2/) 7–10 ft·lb / 9.9–14 N·m

[Throttle body mounting bolts and nuts (NB2) · NB 2001–2005 (BP-Z3); NB 2004–2005 (BP-Z3-TURBO)](https://miatatorque.com/spec/throttle-body-mounting-bolts-and-nuts-nb2/) 14–18 ft·lb / 19–25 N·m

[Idle air control valve screws (NB2) · NB 2001–2005 (BP-Z3); NB 2004–2005 (BP-Z3-TURBO)](https://miatatorque.com/spec/idle-air-control-valve-screws-nb2/) 39–57 in·lb / 4.3–6.5 N·m

[Accelerator cable firewall bracket bolts (NB2) · NB 2001–2005 (BP-Z3); NB 2004–2005 (BP-Z3-TURBO)](https://miatatorque.com/spec/accelerator-cable-firewall-bracket-bolts-nb2/) 70–95 in·lb / 7.9–10.7 N·m

[Accelerator cable bracket bolts (NB2, 2001–03) · NB 2001 (BP-Z3) — 2001 follows the 2002 (1719-1U-01G) manual, the nearest edition; no 2001 manual was checked.; NB 2002–2003 (BP-Z3)](https://miatatorque.com/spec/accelerator-cable-bracket-bolts-nb2-2003/) 14–18 ft·lb / 19–25 N·m

### Turbocharger

[Mazdaspeed turbo inlet hose clamp (NB2) · NB 2004–2005 (BP-Z3-TURBO, 6MT)](https://miatatorque.com/spec/mazdaspeed-turbo-inlet-hose-clamp-nb2/) 43 in·lb / 4.9 N·m

[Mazdaspeed air pipe No. 1 mounting bolt (NB2) · NB 2004–2005 (BP-Z3-TURBO, 6MT)](https://miatatorque.com/spec/mazdaspeed-air-pipe-no-1-mounting-bolt-nb2/) 70–95 in·lb / 7.8–10.8 N·m

[Mazdaspeed air pipe No. 2 mounting bolt (NB2) · NB 2004–2005 (BP-Z3-TURBO, 6MT)](https://miatatorque.com/spec/mazdaspeed-air-pipe-no-2-mounting-bolt-nb2/) 14–19 ft·lb / 18–26 N·m

[Mazdaspeed air pipe No. 2 small mounting bolt (NB2) · NB 2004–2005 (BP-Z3-TURBO, 6MT)](https://miatatorque.com/spec/mazdaspeed-air-pipe-no-2-small-mounting-bolt-nb2/) 70–95 in·lb / 7.8–10.8 N·m

[Mazdaspeed charge air cooler mounting bolts (NB2) · NB 2004–2005 (BP-Z3-TURBO, 6MT)](https://miatatorque.com/spec/mazdaspeed-charge-air-cooler-mounting-bolts-nb2/) 70–95 in·lb / 7.8–10.8 N·m

[Mazdaspeed charge air pipe mounting bolts and nuts (NB2) · NB 2004–2005 (BP-Z3-TURBO, 6MT)](https://miatatorque.com/spec/mazdaspeed-charge-air-pipe-mounting-bolts-and-nuts-nb2/) 70–95 in·lb / 7.8–10.8 N·m

[Turbocharger to exhaust manifold nuts (NB2) · NB 2004–2005 (BP-Z3-TURBO, 6MT)](https://miatatorque.com/spec/turbocharger-to-exhaust-manifold-nuts-nb2/) 28–34 ft·lb / 38.2–46.1 N·m

[Turbocharger and outlet pipe heat shield fasteners (NB2) · NB 2004–2005 (BP-Z3-TURBO, 6MT)](https://miatatorque.com/spec/turbocharger-and-outlet-pipe-heat-shield-fasteners-nb2/) 70–95 in·lb / 7.8–10.8 N·m

## Fluids & capacities

### Fluids & capacities

[Fuel tank capacity (NA6) · NA 1990–1993 (B6) — Other years inferred from 1990 factory evidence.](https://miatatorque.com/spec/fuel-tank-capacity-1992/) / 11.9 US gal / 45 L

## Service specs

### Factory fuel-intake service audit

[Fuel system residual pressure after shutdown (1990–1993) · NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.; NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.](https://miatatorque.com/spec/fuel-system-residual-pressure-1992/) More than 21 psi (147 kPa; 1.5 kg/cm²) after 5 min

[Fuel pump isolated hold pressure (1990–1993) · NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.; NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.](https://miatatorque.com/spec/fuel-pump-isolated-hold-pressure-1992/) More than 50 psi (343 kPa; 3.5 kg/cm²) after 5 min

[Fuel pressure regulator isolation hold test (1990–1993) · NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.; NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.](https://miatatorque.com/spec/fuel-regulator-isolation-hold-test-1992/) More than 21 psi (147 kPa; 1.5 kg/cm²) for 5 min with regulator outlet blocked

[Circuit-opening relay resistance (1990–1993) · NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.; NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.](https://miatatorque.com/spec/circuit-opening-relay-resistance-1992/) STA–E1: 21–43 Ω; B–Fc: 109–226 Ω; B–Fp: infinite resistance.

[Airflow meter fuel-pump switch resistance (1990–1993) · NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.; NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.](https://miatatorque.com/spec/airflow-meter-pump-switch-resistance-1992/) E1–Fc: infinite resistance fully closed; 0 Ω fully open.

[Fuel line pressure at idle and acceleration (2001–2004) · NB 2003 (BP-Z3); NB 2004 (BP-Z3); NB 2001–2002 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 carry-over policy, with hardware, test setup and connector perspective compared against publication 1719-1U-01G. Its existing owner-accepted 2002 source coverage is unchanged; 2001 is carry-over, not an independently verified year.](https://miatatorque.com/spec/fuel-line-running-pressure-2003-2004/) 53–61 psi (370–420 kPa; 3.7–4.3 kgf/cm²)

[Fuel system residual pressure after shutdown (2001–2004) · NB 2003 (BP-Z3); NB 2004 (BP-Z3); NB 2001–2002 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 carry-over policy, with hardware, test setup and connector perspective compared against publication 1719-1U-01G. Its existing owner-accepted 2002 source coverage is unchanged; 2001 is carry-over, not an independently verified year.](https://miatatorque.com/spec/fuel-system-residual-pressure-2003-2004/) More than 36.3 psi (250 kPa; 2.55 kgf/cm²) after 5 min

[Accelerator cable free play (2001–2004) · NB 2003 (BP-Z3); NB 2004 (BP-Z3); NB 2001–2002 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 carry-over policy, with hardware, test setup and connector perspective compared against publication 1719-1U-01G. Its existing owner-accepted 2002 source coverage is unchanged; 2001 is carry-over, not an independently verified year.](https://miatatorque.com/spec/accelerator-cable-free-play-2003-2004/) 0.04–0.11 in (1–3 mm)

[Cold-idle air valve warm-up inspection (1990–1993) · NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.; NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.](https://miatatorque.com/spec/cold-idle-air-valve-warmup-inspection-1992/) Begin below 68 °F (20 °C) coolant temperature; engine speed must gradually decrease during warm-up.

[ISC valve disconnect response at warm idle (1990–1993) · NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.; NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.](https://miatatorque.com/spec/isc-valve-disconnection-speed-test-1992/) At normal warm idle, disconnect the black two-pin ISC connector: valve clicks and speed rises to approximately 1,200 rpm.

[PCV valve directional airflow check (2001–2003) · NB 2003 (BP-Z3); NB 2001–2002 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 carry-over policy, with hardware, test setup and connector perspective compared against publication 1719-1U-01G. Its existing owner-accepted 2002 source coverage is unchanged; 2001 is carry-over, not an independently verified year.](https://miatatorque.com/spec/pcv-valve-directional-airflow-2003/) Removed factory PCV valve: air applied at the wide cylindrical body end must flow through; air applied at the narrow hose nipple beyond the flange must not flow through.

[EVAP catch tank leakage check (2001–2005) · NB 2003–2005 (BP-Z3); NB 2001–2002 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 carry-over policy, with hardware, test setup and connector perspective compared against publication 1719-1U-01G. Its existing owner-accepted 2002 source coverage is unchanged; 2001 is carry-over, not an independently verified year.](https://miatatorque.com/spec/evap-catch-tank-leak-check-2003/) With the removed EVAP catch tank’s purge-solenoid-side port plugged, blow through its charcoal-canister-side port; there must be no air leakage.

[EVAP air filter airflow in both directions (2001–2003) · NB 2003 (BP-Z3); NB 2001–2002 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 carry-over policy, with hardware, test setup and connector perspective compared against publication 1719-1U-01G. Its existing owner-accepted 2002 source coverage is unchanged; 2001 is carry-over, not an independently verified year.](https://miatatorque.com/spec/evap-air-filter-bidirectional-airflow-2003/) Removed EVAP air filter: air must pass from the canister-drain-cut-valve (CDCV) connection to the evaporative-chamber connection, and in the reverse direction.

[Catalytic converter oxygen-sensor inversion test (2001–2003) · NB 2003 (BP-Z3); NB 2001–2002 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 carry-over policy, with hardware, test setup and connector perspective compared against publication 1719-1U-01G. Its existing owner-accepted 2002 source coverage is unchanged; 2001 is carry-over, not an independently verified year.](https://miatatorque.com/spec/twc-oxygen-sensor-inversion-test-2003/) With no HO2S DTC detected, warm the front catalyst by driving 10 min at 65—96 km/h {40—60 mph}; then record O2S11/O2S12 for 1 min at idle. Count crossings of 0.5 V. Upstream crossings ÷ downstream crossings must be 2 or more; no downstream crossings also passes.

[Evaporative chamber airflow check (2001–2003) · NB 2003 (BP-Z3); NB 2001–2002 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 carry-over policy, with hardware, test setup and connector perspective compared against publication 1719-1U-01G. Its existing owner-accepted 2002 source coverage is unchanged; 2001 is carry-over, not an independently verified year.](https://miatatorque.com/spec/evaporative-chamber-airflow-2003/) Removed evaporative chamber: blow through its large hose neck and verify airflow from the pair of central openings in the perforated end face.

[Idle speed inspection interval — U.S. schedules (2001–2003) · NB 2003 — U.S.A. Schedule 1 normal driving or Schedule 2 unique driving conditions, as stated. Non-U.S. market applicability is not established here.; NB 2001–2002 — U.S.A. Schedule 1 normal driving or Schedule 2 unique driving conditions, as stated. Non-U.S. market applicability is not established here. 2001–2002 applicability follows the owner-approved early-NB2 carry-over policy, with the applicable factory schedule, facts and service context compared against publication 1719-1U-01G. Its existing owner-accepted 2002 source coverage is unchanged; 2001 is carry-over, not an independently verified year.](https://miatatorque.com/spec/idle-speed-inspection-interval-us-2003/) Schedules 1 and 2: inspect every 24 months or 48,000 kilometers (30,000 miles), whichever comes first.

[Fuel line and hose inspection interval — U.S. schedules (2001–2003) · NB 2003 — U.S.A. Schedule 1 normal driving or Schedule 2 unique driving conditions, as stated. Non-U.S. market applicability is not established here.; NB 2001–2002 — U.S.A. Schedule 1 normal driving or Schedule 2 unique driving conditions, as stated. Non-U.S. market applicability is not established here. 2001–2002 applicability follows the owner-approved early-NB2 carry-over policy, with the applicable factory schedule, facts and service context compared against publication 1719-1U-01G. Its existing owner-accepted 2002 source coverage is unchanged; 2001 is carry-over, not an independently verified year.](https://miatatorque.com/spec/fuel-lines-hoses-inspection-interval-us-2003/) Schedules 1 and 2: inspect every 24 months or 48,000 kilometers (30,000 miles), whichever comes first.

[Emission hose and tube inspection interval — U.S. schedules (2001–2003) · NB 2003 — U.S.A. Schedules 1 and 2 only.; NB 2001–2002 — U.S.A. Schedules 1 and 2 only. 2001–2002 applicability follows the owner-approved early-NB2 carry-over policy, with the applicable factory schedule, facts and service context compared against publication 1719-1U-01G. Its existing owner-accepted 2002 source coverage is unchanged; 2001 is carry-over, not an independently verified year.](https://miatatorque.com/spec/emission-hoses-tubes-inspection-interval-us-2003/) Schedules 1 and 2: inspect at 48 months or 96,000 kilometers (60,000 miles), whichever comes first; continue the recommended interval thereafter.

[VTCS shutter actuator vacuum test (2001–2004) · NB 2003 (BP-Z3); NB 2004 (BP-Z3); NB 2001–2002 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 carry-over policy, with hardware, test setup and connector perspective compared against publication 1719-1U-01G. Its existing owner-accepted 2002 source coverage is unchanged; 2001 is carry-over, not an independently verified year.](https://miatatorque.com/spec/vtcs-actuator-vacuum-test-2003-2004/) Starts moving at approximately −9.3 kPa {−69.8 mmHg, −2.7 inHg}; fully pulled below −34.7 kPa {−260 mmHg, −10.2 inHg}; not pulled above −6.7 kPa {−51 mmHg, −2.0 inHg}.

[Idle-air-control valve winding resistance (2001–2004) · NB 2003 (BP-Z3); NB 2004 (BP-Z3); NB 2001–2002 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 carry-over policy, with hardware, test setup and connector perspective compared against publication 1719-1U-01G. Its existing owner-accepted 2002 source coverage is unchanged; 2001 is carry-over, not an independently verified year.](https://miatatorque.com/spec/iac-valve-winding-resistance-2003-2004/) 8.7–10.5 Ω at 75 °F (24 °C)

[EGR valve stepper-coil resistance (2001–2004) · NB 2003 (BP-Z3); NB 2004 (BP-Z3); NB 2001–2002 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 carry-over policy, with hardware, test setup and connector perspective compared against publication 1719-1U-01G. Its existing owner-accepted 2002 source coverage is unchanged; 2001 is carry-over, not an independently verified year.](https://miatatorque.com/spec/egr-stepper-coil-resistance-2003-2004/) Approximately 20–24 Ω for each pair: C–E, C–A, D–B and D–F.

[MAF and calculated-load scan references (2001–2004) · NB 2003 (BP-Z3); NB 2004 (BP-Z3); NB 2001–2002 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 carry-over policy, with hardware and test setup compared against publication 1719-1U-01G. Its existing owner-accepted 2002 source coverage is unchanged; 2001 is carry-over, not an independently verified year.](https://miatatorque.com/spec/maf-scan-reference-2003-2004/) Idle at 750–850 rpm: MT 2.2–3.2 g/s and 15.0–23.0% load; AT 2.3–3.2 g/s and 14.0–23.0% load. At 2,500 rpm with no load, neutral or P: 6.5–8.5 g/s and 14.0–21.0% load.

[EVAP purge-flow monitor operating conditions (2003) · NB 2003 (BP-Z3)](https://miatatorque.com/spec/evap-purge-flow-monitor-conditions-2003/) P0441 monitor: engine 1,100–2,700 rpm and throttle opening 11–25%.

[EVAP leak-detection pump reference-orifice nominal hole (2003) · NB 2003 (BP-Z3)](https://miatatorque.com/spec/evap-pump-reference-orifice-nominal-hole-2003/) Internal reference-orifice hole: 0.02 in (0.5 mm).

[Throttle-position performance detection conditions (2004 Mazdaspeed) · NB 2004 (BP-Z3-TURBO, 6MT)](https://miatatorque.com/spec/tp-performance-dtc-conditions-msm-2004/) P0121 stuck closed: throttle below 12.5% for 5 s, with ECT above 158 °F (70 °C) and MAF above 81 g/s {11 lb/min}. Stuck open: throttle above 50% for 5 s, with engine above 500 rpm and MAF below 5.3 g/s {0.70 lb/min}.

[EVAP purge-flow monitor operating conditions (2004 Mazdaspeed) · NB 2004 (BP-Z3-TURBO, 6MT)](https://miatatorque.com/spec/evap-purge-flow-dtc-monitor-conditions-msm-2004/) P0441 monitor conditions: engine 1,100–3,500 rpm; vehicle 34–119 km/h {21.1–73.7 mph}; throttle opening 5.5–14.5%.

[Factory throttle-body nominal throat diameter (1990–1993) · NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.; NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.](https://miatatorque.com/spec/throttle-body-nominal-throat-diameter-1992/) 2.2 in (55 mm)

[Purge-control solenoid winding resistance (1990–1993) · NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.; NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.](https://miatatorque.com/spec/purge-solenoid-winding-resistance-1992/) 23–27 Ω at 68 °F (20 °C)

[Cold-idle air valve opening temperature (1990–1993) · NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.; NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.](https://miatatorque.com/spec/cold-idle-air-valve-opening-temperature-1992/) Opens below 104 °F (40 °C)

[Turbo wastegate regulating valve normal control conditions (2004) · NB 2004 (BP-Z3-TURBO, 6MT)](https://miatatorque.com/spec/turbo-wastegate-regulating-valve-control-conditions-2004/) After engine warm-up, at 5,250 rpm or more, with throttle fully open.

### Early NB2 factory service checks

[Intake manifold gasket orientation (2001–2002) · NB 2001–2002 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 carry-over policy, with hardware and test setup compared against publication 1719-1U-01G. Its existing owner-accepted 2002 source coverage is unchanged; 2001 is carry-over, not an independently verified year.](https://miatatorque.com/spec/intake-manifold-gasket-orientation-early-nb2/) Factory intake manifold gasket: convex side faces the intake manifold.

[Dynamic chamber gasket orientation (2001–2002) · NB 2001–2002 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 carry-over policy, with hardware and test setup compared against publication 1719-1U-01G. Its existing owner-accepted 2002 source coverage is unchanged; 2001 is carry-over, not an independently verified year.](https://miatatorque.com/spec/dynamic-chamber-gasket-orientation-early-nb2/) Factory dynamic chamber gasket: convex side faces the intake manifold.

[Dynamic chamber bracket tightening order (2001–2002) · NB 2001–2002 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 carry-over policy, with hardware and test setup compared against publication 1719-1U-01G. Its existing owner-accepted 2002 source coverage is unchanged; 2001 is carry-over, not an independently verified year.](https://miatatorque.com/spec/dynamic-chamber-bracket-tightening-order-early-nb2/) After fitting the bracket bolts firmly, tighten the dynamic-chamber-side bolt before the fuel-distributor-side bolt.

[Fuel injector O-ring installation (2001–2002) · NB 2001–2002 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 carry-over policy, with hardware and test setup compared against publication 1719-1U-01G. Its existing owner-accepted 2002 source coverage is unchanged; 2001 is carry-over, not an independently verified year.](https://miatatorque.com/spec/fuel-injector-o-ring-installation-early-nb2/) Use new injector O-rings with a small amount of engine oil; keep sealing surfaces clean and insert with a light twisting motion to avoid folding the rings.

[Fuel quick-release connector assembly (2001–2005) · NB 2001–2005 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 carry-over policy, with hardware and test setup compared against publication 1719-1U-01G. Its existing owner-accepted 2002 source coverage is unchanged; 2001 is carry-over, not an independently verified year.](https://miatatorque.com/spec/fuel-quick-release-connector-assembly-early-nb2/) Inspect and clean the fuel-pipe and connector interiors; push together until a click is heard, then pull by hand to confirm secure locking.

[Fuel pump seating in bracket (2001–2005) · NB 2001–2005 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 carry-over policy, with hardware and test setup compared against publication 1719-1U-01G. Its existing owner-accepted 2002 source coverage is unchanged; 2001 is carry-over, not an independently verified year.](https://miatatorque.com/spec/fuel-pump-bracket-seating-early-nb2/) After fitting the pump, pull it downward until it sits flush against the lower bracket with no gap.

### Early NB2 factory service checks

[VTCS check/delay valve directional airflow — early NB2 · NB 2001–2002 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 carry-over policy, with hardware, test setup and connector perspective compared against publication 1719-1U-01G. Its existing owner-accepted 2002 source coverage is unchanged; 2001 is carry-over, not an independently verified year.](https://miatatorque.com/spec/vtcs-check-delay-valve-airflow-early-nb2/) Removed original VTCS check/delay valve: flow from the rounded wide-body end toward the tapered-body end; reverse flow blocked.

[Canister drain-cut valve airflow test — early NB2 · NB 2001–2002 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 carry-over policy, with hardware, test setup and connector perspective compared against publication 1719-1U-01G. Its existing owner-accepted 2002 source coverage is unchanged; 2001 is carry-over, not an independently verified year.](https://miatatorque.com/spec/canister-drain-cut-valve-airflow-early-nb2/) Removed CDCV: airflow between its two hose ports when unpowered; with electrical A positive / B grounded, airflow blocked.

[Purge solenoid airflow test — early NB2 · NB 2001–2002 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 carry-over policy, with hardware, test setup and connector perspective compared against publication 1719-1U-01G. Its existing owner-accepted 2002 source coverage is unchanged; 2001 is carry-over, not an independently verified year.](https://miatatorque.com/spec/purge-solenoid-airflow-early-nb2/) Removed purge valve: no airflow between its hose ports when unpowered; with electrical A positive / B grounded, airflow passes.

[Canister drain-cut valve hose seating — early NB2 · NB 2001–2002 (BP-Z3) — 2001–2002 applicability follows the owner-approved early-NB2 carry-over policy, with hardware, test setup and connector perspective compared against publication 1719-1U-01G. Its existing owner-accepted 2002 source coverage is unchanged; 2001 is carry-over, not an independently verified year.](https://miatatorque.com/spec/canister-drain-cut-valve-hose-seating-early-nb2/) Seat the canister drain-cut valve’s evaporative hose against its stopper.

### Service measurements and fasteners

[Engine idle speed — adjustment condition (NA6) · NA 1990–1993 (B6, 5MT) — 1991 follows the 1990 manual and 1993 follows the 1992 manual, the nearest editions; no 1991 or 1993 manual was checked.](https://miatatorque.com/spec/engine-idle-speed-na6/) 850 ± 50 rpm (Neutral)

[Accelerator cable free play (NA6) · NA 1990–1993 (B6) — Other years inferred from 1990 factory evidence.](https://miatatorque.com/spec/accelerator-cable-free-play-na6/) 0.039–0.118 in (1–3 mm)

[Fuel injector resistance (NA6) · NA 1990–1993 (B6) — Other years inferred from 1990 factory evidence.](https://miatatorque.com/spec/injector-resistance-na6/) 12–16 (at ≈68 °F (20°C), 68°F) Ω

[ISC valve solenoid resistance (NA6) · NA 1990–1993 (B6) — Other years inferred from 1990 factory evidence.](https://miatatorque.com/spec/isc-valve-resistance-na6/) 11–13 (at ≈68 °F (20°C), 68°F) Ω

[Fuel line pressure — engine off, pump operating (NA6) · NA 1990–1993 (B6) — Other years inferred from 1990 factory evidence.](https://miatatorque.com/spec/fuel-pressure-regulator-pressure-na6/) 38–46 psi (265–314 kPa; 2.7–3.2 kg/cm²)

[Fuel line pressure — engine idling (NA6) · NA 1990–1993 (B6) — Other years inferred from 1990 factory evidence.](https://miatatorque.com/spec/fuel-line-pressure-at-idle-na6/) 31–38 psi (216–265 kPa; 2.2–2.7 kg/cm²)

### Service measurements and fasteners

[Fuel injector resistance (NB2, non-turbo) · NB 2001–2005 (BP-Z3) — Other years inferred from 2003 factory evidence.](https://miatatorque.com/spec/fuel-injector-resistance-nb2/) 12–13 ohms at 68 °F (20 °C)

[Fuel injector leakage limit (NB2, non-turbo) · NB 2001–2005 (BP-Z3) — Other years inferred from 2003 factory evidence.](https://miatatorque.com/spec/fuel-injector-leakage-limit-nb2/) Less than 1 drop in 2 min

[Fuel pump residual hold pressure (NB2, non-turbo) · NB 2001–2005 (BP-Z3) — Other years inferred from 2003 factory evidence.](https://miatatorque.com/spec/fuel-pump-hold-pressure-inspection-nb2/) More than 50 psi (343 kPa; 3.5 kgf/cm²) after 5 min

[Idle-up speed — electrical loads, manual transmission (NB2 non-turbo) · NB 2001–2005 (BP-Z3, 5MT/6MT) — Other years inferred within NB2 non-turbo family from actual 2003/2005 factory evidence.](https://miatatorque.com/spec/idle-up-electrical-load-mt-nb2/) 750–850 rpm (800 ± 50 rpm)

[Idle-up speed — electrical loads (Mazdaspeed) · NB 2004–2005 (BP-Z3-TURBO, 6MT) — Actual2005 factory evidence; 2004 inferred within MSM family.](https://miatatorque.com/spec/idle-up-electrical-load-msm/) 800–900 rpm (850 ± 50 rpm)

[Idle-up speed — power steering, manual transmission (NB2 and Mazdaspeed) · NB 2001–2005 (BP-Z3, 5MT/6MT) — Other years inferred within NB2 non-turbo family from actual 2003/2005 factory evidence.; NB 2004–2005 (BP-Z3-TURBO, 6MT) — Actual2005 factory evidence; 2004 inferred within MSM family.](https://miatatorque.com/spec/idle-up-power-steering-mt-nb2/) 750–850 rpm (800 ± 50 rpm)

[Idle-up speed — A/C, manual transmission (NB2 and Mazdaspeed) · NB 2001–2005 (BP-Z3, 5MT/6MT) — Other years inferred within NB2 non-turbo family from actual 2003/2005 factory evidence.; NB 2004–2005 (BP-Z3-TURBO, 6MT) — Actual2005 factory evidence; 2004 inferred within MSM family.](https://miatatorque.com/spec/idle-up-air-conditioning-mt-nb2/) 950–1050 rpm (1000 ± 50 rpm)

[Idle-up speed — automatic in Neutral or Park (NB2 non-turbo) · NB 2001–2005 (BP-Z3, 4AT) — Other years inferred within NB2 non-turbo family from actual 2003/2005 factory evidence.](https://miatatorque.com/spec/idle-up-at-neutral-park-nb2/) 750–850 rpm (800 ± 50 rpm)

[Idle-up speed — automatic in Drive (NB2 non-turbo) · NB 2001–2005 (BP-Z3, 4AT) — Other years inferred within NB2 non-turbo family from actual 2003/2005 factory evidence.](https://miatatorque.com/spec/idle-up-at-drive-nb2/) 700–800 rpm (750 ± 50 rpm)

[Engine idle speed — adjustment condition (NA8 MT) · NA 1994–1997 (BP, 5MT) — Other years inferred from 1994 factory evidence.](https://miatatorque.com/spec/engine-idle-speed-na8-mt/) 800–900 (850 ± 50) rpm, Neutral

[Engine idle speed — adjustment condition (NA8 AT) · NA 1994–1997 (BP, 4AT) — Other years inferred from 1994 factory evidence.](https://miatatorque.com/spec/engine-idle-speed-na8-at/) 750–850 (800 ± 50) rpm, P range

### Factory service specifications (1999)

[Fuel pump maximum pressure test (1999–2000) · NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.](https://miatatorque.com/spec/fuel-pump-maximum-pressure-1999/) Less than 92 psi (640 kPa; 6.5 kgf/cm²).

[Fuel pump isolated hold pressure (1999–2000) · NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.](https://miatatorque.com/spec/fuel-pump-isolated-hold-pressure-1999/) More than 50 psi (340 kPa; 3.5 kgf/cm²), five minutes after pump shutdown.

[Fuel line pressure with pump operating (1999–2000) · NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.](https://miatatorque.com/spec/fuel-line-pump-on-pressure-1999/) 53–61 psi (370–420 kPa; 3.7–4.3 kgf/cm²).

[Fuel system residual pressure (1999–2000) · NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.](https://miatatorque.com/spec/fuel-system-residual-pressure-1999/) More than 36.3 psi (250 kPa; 2.55 kgf/cm²), five minutes after pump shutdown.

[Fuel injector resistance (1999–2000) · NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.](https://miatatorque.com/spec/fuel-injector-resistance-1999/) 12–16 Ω at 68 °F (20 °C).

[Fuel injector nozzle leakage test (1999–2000) · NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.](https://miatatorque.com/spec/fuel-injector-nozzle-leakage-1999/) Less than 1 drop in 2 minutes.

[Fuel line pressure at idle (1999–2000) · NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.](https://miatatorque.com/spec/fuel-line-idle-pressure-1999/) 53–61 psi (370–420 kPa; 3.7–4.3 kgf/cm²).

[EVAP whole-system vacuum hold (1999–2000) · NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.](https://miatatorque.com/spec/evap-whole-system-vacuum-hold-1999/) Apply 1.7 kPa (13 mmHg, 0.5 inHg) vacuum; the specified reading must remain for at least two minutes.

[EVAP canister-to-tank vacuum hold (1999–2000) · NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.](https://miatatorque.com/spec/evap-canister-to-tank-vacuum-hold-1999/) Apply 1.7 kPa (13 mmHg, 0.5 inHg) vacuum; the specified reading must remain for at least two minutes.

[EVAP canister-to-purge section vacuum hold (1999–2000) · NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.](https://miatatorque.com/spec/evap-canister-to-purge-vacuum-hold-1999/) Apply 3.3 kPa (25 mmHg, 1.0 inHg) vacuum; the specified reading must remain for at least two minutes.

[Fuel-cut injector-duration test (1999–2000) · NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.](https://miatatorque.com/spec/fuel-cut-injector-duration-test-1999/) During the specified deceleration: 0 msec injector duration; 2–5 msec when engine speed drops below 1,000 rpm.

[Idle air control valve resistance (1999–2000) · NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.](https://miatatorque.com/spec/iac-valve-resistance-1999/) 8.7—10.5 Ω at 75 °F (24 °C).

[VICS one-way check valve airflow (1999–2000) · NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.](https://miatatorque.com/spec/vics-one-way-check-valve-airflow-1999/) Air flows A→B; air does not flow B→A.

[VICS shutter actuator vacuum test (1999–2000) · NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.](https://miatatorque.com/spec/vics-shutter-actuator-vacuum-test-1999/) Above −1.3 kPa {−10 mmHg, −0.4 inHg}: not pulled; −1.3—−4.0 kPa {−10—−30 mmHg, −0.4—−1.1 inHg}: starts moving; below −26 kPa {−190 mmHg, −7.5 inHg}: fully pulled.

[VICS solenoid valve airflow test (1999–2000) · NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.](https://miatatorque.com/spec/vics-solenoid-airflow-test-1999/) Unpowered: A–B terminal continuity and airflow between ports B–C. Battery positive on terminal A and ground on B: airflow between ports A–B.

[Accelerator cable free play (1999–2000) · NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.](https://miatatorque.com/spec/accelerator-cable-free-play-1999/) 0.04—0.11 in (1—3 mm).

[Fuel pump connector continuity test (1999–2000) · NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.](https://miatatorque.com/spec/fuel-pump-continuity-1999/) Continuity between pump terminals B and D.

[Fuel pump relay continuity test (1999–2000) · NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.](https://miatatorque.com/spec/fuel-pump-relay-continuity-1999/) Unpowered: continuity A–B. Battery positive on A and ground on B: continuity C–E.

[Fuel injector injection volume (1999–2000) · NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.](https://miatatorque.com/spec/fuel-injector-injection-volume-1999/) 66—82 ml {66—82 cc, 2.3—2.7 fl oz}/15 sec.

[Tank pressure control valve airflow test (1999–2000) · NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.](https://miatatorque.com/spec/tpcv-airflow-test-1999/) Unpowered, pressure applied to port A: 0—+0.20 kPa {0—+1.47 mmHg, 0—+0.06 inHg}: no airflow; above +0.98 kPa {+7.36 mmHg, +0.29 inHg}: airflow; below −0.98 kPa {−7.36 mmHg, −0.29 inHg}: airflow. Powered terminal A positive/B ground: smooth airflow.

[Canister drain-cut valve airflow test (1999–2000) · NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.](https://miatatorque.com/spec/canister-drain-cut-valve-airflow-1999/) Unpowered: terminal A–B continuity and airflow between ports A and B. Terminal A battery positive/B ground: no airflow between ports A and B.

[Purge solenoid airflow test (1999–2000) · NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.](https://miatatorque.com/spec/purge-solenoid-airflow-test-1999/) Unpowered: terminal A–B continuity, no airflow between ports A and B. Terminal A battery positive/B ground: airflow between ports A and B.

[Evaporative chamber airflow test (1999–2000) · NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.](https://miatatorque.com/spec/evaporative-chamber-airflow-1999/) Air blown into port A must flow from port B.

[EGR valve coil resistance (1999–2000) · NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.](https://miatatorque.com/spec/egr-valve-coil-resistance-1999/) Approximately 22 Ω for each pair C–E, C–A, D–B and D–F.

[EGR boost sensor solenoid airflow test (1999–2000) · NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.](https://miatatorque.com/spec/egr-boost-solenoid-airflow-test-1999/) Unpowered: electrical A–B continuity; airflow between pneumatic B and C. Electrical A battery positive/B ground: airflow between pneumatic A and B.

[PCV valve directional airflow check (1999–2000) · NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.](https://miatatorque.com/spec/pcv-valve-directional-airflow-1999/) Air applied from port A: airflow. Air applied from port B: no airflow.

[Intake manifold vacuum at idle (1999–2000) · NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.](https://miatatorque.com/spec/intake-manifold-vacuum-at-idle-1999/) At idle: more than 60 kPa {450 mmHg, 18 inHg} manifold vacuum.

[Fuel-filler vent cut valve airflow inspection (1999–2000) · NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.](https://miatatorque.com/spec/fuel-filler-vent-cut-valve-airflow-1999/) Cap installed: air passes from rollover-valve connection to TPCV connection. Cap removed and internal filler-port lever depressed: air must not pass along that same path.

### Factory service specifications (2003)

[VTCS solenoid valve resistance screening (2001–2004) · NB 2001–2004 (BP-Z3) — 2002 applicability is supported by matching text in publication 1719-1U-01G; 2001 follows the owner-approved early-NB2 carry-over policy and is not an independently verified year.](https://miatatorque.com/spec/vtcs-solenoid-resistance-screening-2003/) DTC P2009/P2010 component screening: resistance must be more than 28 ohms.

[Intake manifold vacuum at idle (2001–2003) · NB 2001–2003 (BP-Z3) — 2002 applicability is supported by matching text in publication 1719-1U-01G; 2001 follows the owner-approved early-NB2 carry-over policy and is not an independently verified year.](https://miatatorque.com/spec/intake-manifold-vacuum-at-idle-2003/) More than 60 kPa {450 mmHg, 18 inHg} vacuum at idle.

[VTCS check/delay valve directional airflow (2003) · NB 2003 (BP-Z3)](https://miatatorque.com/spec/vtcs-check-delay-valve-airflow-2003/) Removed original valve: airflow from the rounded-body port A to the tapered-body port B; reverse flow blocked.

[Intake manifold gasket orientation (2003) · NB 2003 (BP-Z3)](https://miatatorque.com/spec/intake-manifold-gasket-orientation-2003/) Factory intake manifold gasket: convex side faces the intake manifold.

[Dynamic chamber gasket orientation (2003) · NB 2003 (BP-Z3)](https://miatatorque.com/spec/dynamic-chamber-gasket-orientation-2003/) Factory dynamic chamber gasket: convex side faces the intake manifold.

[Dynamic chamber bracket tightening order (2003) · NB 2003 (BP-Z3)](https://miatatorque.com/spec/dynamic-chamber-bracket-tightening-order-2003/) After fitting the bracket bolts firmly, tighten the dynamic-chamber-side bolt before the fuel-distributor-side bolt.

[Fuel pump isolated continuity (2003) · NB 2003 (BP-Z3)](https://miatatorque.com/spec/fuel-pump-continuity-2003/) Continuity between pump terminals B and D.

[Fuel drawing pump hose preparation (2003) · NB 2003 (BP-Z3)](https://miatatorque.com/spec/fuel-drawing-pump-hose-preparation-2003/) Hose outer diameter 0.51 in (13 mm); length 85.0 in (2160 mm) or longer; illustrated inlet end cut at 30°.

### Factory fuel and emission service specifications (2004)

[Purge solenoid valve component resistance (2004) · NB 2004 (BP-Z3)](https://miatatorque.com/spec/purge-solenoid-winding-resistance-2004/) Between the disconnected valve’s component terminals: 22–26 ohms.

[EVAP canister-to-tank isolated vacuum retention (2004) · NB 2004 (BP-Z3)](https://miatatorque.com/spec/evap-canister-to-tank-vacuum-hold-2004/) Apply 1.7 kPa {13 mmHg, 0.5 inHg} vacuum to the disconnected hose; hold for at least 2 min.

[EVAP canister-to-purge isolated vacuum retention (2004) · NB 2004 (BP-Z3)](https://miatatorque.com/spec/evap-canister-to-purge-vacuum-hold-2004/) Apply 3.3 kPa {25 mmHg, 1.0 inHg} vacuum to the disconnected hose; hold for at least 2 min.

[Intake manifold vacuum at idle (2004) · NB 2004 (BP-Z3)](https://miatatorque.com/spec/intake-manifold-vacuum-at-idle-2004/) More than 60 kPa {450 mmHg, 18 inHg} vacuum at idle.

[Dynamic chamber bracket tightening order (2004–2005) · NB 2004–2005 (BP-Z3)](https://miatatorque.com/spec/dynamic-chamber-bracket-tightening-order-2004/) After fitting the bracket bolts firmly, tighten the dynamic-chamber-side bolt before the fuel-distributor-side bolt.

[Fuel pump isolated continuity (2004) · NB 2004 (BP-Z3)](https://miatatorque.com/spec/fuel-pump-continuity-2004/) Continuity between pump terminals B and D.

[Fuel drawing pump hose preparation (2004) · NB 2004 (BP-Z3)](https://miatatorque.com/spec/fuel-drawing-pump-hose-preparation-2004/) Hose outer diameter 0.51 in (13 mm); length 85.0 in (2160 mm) or longer; illustrated inlet end cut at 30°.

[PCV valve directional airflow check (2004) · NB 2004 (BP-Z3)](https://miatatorque.com/spec/pcv-valve-directional-airflow-2004/) Removed factory PCV valve: air applied at the wide cylindrical body end must flow through; air applied at the narrow hose nipple beyond the flange must not flow through.

[Purge solenoid vacuum and evaporative hose seating (2001–2004) · NB 2001–2004 (BP-Z3) — 2002 applicability is supported by matching text in publication 1719-1U-01G; 2001 follows the owner-approved early-NB2 carry-over policy and is not an independently verified year.](https://miatatorque.com/spec/purge-solenoid-hose-seating-2004/) Seat both the vacuum hose and evaporative hose against their stoppers.

[Evaporative chamber airflow check (2004–2005) · NB 2004–2005 (BP-Z3)](https://miatatorque.com/spec/evaporative-chamber-airflow-2004/) Removed evaporative chamber: blow through its large hose neck and verify airflow from the pair of central openings in the perforated end face.

### Factory source validation additions (2005)

[Fuel line pressure at idle and acceleration (2004–2005) · NB 2005 (BP-Z3/BP-Z3-TURBO); NB 2004 (BP-Z3-TURBO) — 2005 Mazdaspeed applicability is supported by the cited 2005 factory pages; 2004 Mazdaspeed follows the owner-approved 2004–2005 Mazdaspeed carry-over policy. No 2004 Mazdaspeed revision verification is claimed.](https://miatatorque.com/spec/fuel-line-running-pressure-2005/) 53–61 psi (370–420 kPa; 3.7–4.3 kgf/cm²)

[Purge solenoid valve component resistance (2004–2005) · NB 2005 (BP-Z3/BP-Z3-TURBO); NB 2004 (BP-Z3-TURBO) — 2005 Mazdaspeed applicability is supported by the cited 2005 factory pages; 2004 Mazdaspeed follows the owner-approved 2004–2005 Mazdaspeed carry-over policy. No 2004 Mazdaspeed revision verification is claimed.](https://miatatorque.com/spec/purge-solenoid-winding-resistance-2005/) Between the disconnected valve’s component terminals: 22–26 ohms.

[EGR boost sensor solenoid valve resistance (2004–2005) · NB 2005 (BP-Z3/BP-Z3-TURBO); NB 2004 (BP-Z3-TURBO) — 2005 Mazdaspeed applicability is supported by the cited 2005 factory pages; 2004 Mazdaspeed follows the owner-approved 2004–2005 Mazdaspeed carry-over policy. No 2004 Mazdaspeed revision verification is claimed.](https://miatatorque.com/spec/egr-boost-sensor-solenoid-resistance-2005/) Between the disconnected valve’s component-side terminals: 23–27 ohms.

[EVAP canister-to-tank isolated vacuum retention (2004–2005) · NB 2005 (BP-Z3/BP-Z3-TURBO); NB 2004 (BP-Z3-TURBO) — 2005 Mazdaspeed applicability is supported by the cited 2005 factory pages; 2004 Mazdaspeed follows the owner-approved 2004–2005 Mazdaspeed carry-over policy. No 2004 Mazdaspeed revision verification is claimed.](https://miatatorque.com/spec/evap-canister-to-tank-vacuum-hold-2005/) Apply 1.7 kPa {13 mmHg, 0.5 inHg} vacuum to the disconnected hose; hold for at least 2 min.

[EVAP canister-to-purge isolated vacuum retention (2004–2005) · NB 2005 (BP-Z3/BP-Z3-TURBO); NB 2004 (BP-Z3-TURBO) — 2005 Mazdaspeed applicability is supported by the cited 2005 factory pages; 2004 Mazdaspeed follows the owner-approved 2004–2005 Mazdaspeed carry-over policy. No 2004 Mazdaspeed revision verification is claimed.](https://miatatorque.com/spec/evap-canister-to-purge-vacuum-hold-2005/) Apply 3.3 kPa {25 mmHg, 1.0 inHg} vacuum to the disconnected hose; hold for at least 2 min.

[Intake manifold vacuum at idle (2004–2005) · NB 2005 (BP-Z3/BP-Z3-TURBO); NB 2004 (BP-Z3-TURBO) — 2005 Mazdaspeed applicability is supported by the cited 2005 factory pages; 2004 Mazdaspeed follows the owner-approved 2004–2005 Mazdaspeed carry-over policy. No 2004 Mazdaspeed revision verification is claimed.](https://miatatorque.com/spec/intake-manifold-vacuum-at-idle-2005/) More than 60 kPa {450 mmHg, 18 inHg} vacuum at idle.

### Factory service specifications

[Intake manifold vacuum at idle (1990–1991) · NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.](https://miatatorque.com/spec/intake-manifold-idle-vacuum-1990/) More than 450 mmHg (17.7 inHg) at idle

[Dashpot lever contact speed (1990–1991) · NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.](https://miatatorque.com/spec/dashpot-contact-speed-1990/) 2,500 ± 150 rpm as engine speed slowly decreases

[Deceleration fuel cut inspection speed (1990–1991) · NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.](https://miatatorque.com/spec/deceleration-fuel-cut-inspection-speed-1990/) Above 1,900 rpm after warm-up, during deceleration

[Fuel tank hose insertion depth (1990–1991) · NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.](https://miatatorque.com/spec/fuel-tank-hose-insertion-depth-1990/) Main fuel, return and evaporation hoses at tank fittings at least 1.0 in (25 mm); filler hose at both pipes at least 1.4 in (35 mm).

[Circuit-opening relay switching test (1990–1991) · NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.](https://miatatorque.com/spec/circuit-opening-relay-switching-test-1990/) Apply 12 V to STA and ground E1 — B–Fp continuity; apply 12 V to B and ground Fc — Fp at battery voltage.

[Circuit-opening relay circuit voltage (1990–1991) · NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.](https://miatatorque.com/spec/circuit-opening-relay-circuit-voltage-1990/) Terminal order Fp, Fc, B, STA, E1: ignition ON — 0, 12, 12, 0, 0 V; START — 12, 0, 12, 12, 0 V; idle — 12, 0, 12, 0, 0 V.

[Fuel injector leakage test (1990–1991) · NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.](https://miatatorque.com/spec/fuel-injector-leakage-test-1990/) No nozzle leakage; a drop after 1 minute is acceptable.

[Two-way check valve vacuum test (1990–1991) · NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.](https://miatatorque.com/spec/two-way-check-valve-vacuum-test-1990/) Airflow at approximately 37 mmHg (1.46 inHg) vacuum at port A and approximately 44 mmHg (1.73 inHg) at port B.

[PCV valve directional airflow check (1990–1991) · NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.](https://miatatorque.com/spec/pcv-valve-directional-airflow-1990/) Removed valve: air passes from port A to B; no air passes from port B to A.

[Purge solenoid airflow test (1990–1991) · NA 1990–1991 (B6) — 1990 applicability is supported by the cited 1990 factory pages; 1991 follows the owner-approved 1990-to-short-crank-1991 carry-over policy. No 1991 revision verification or long-crank applicability is claimed.](https://miatatorque.com/spec/purge-solenoid-airflow-test-1990/) No airflow when unpowered; airflow with 12 V and ground applied to the disconnected solenoid terminals.

[Intake manifold vacuum at idle (1992–1993) · NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.](https://miatatorque.com/spec/intake-manifold-idle-vacuum-1992/) More than 450 mmHg (17.7 inHg) at idle

[Dashpot lever contact speed (1992–1993) · NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.](https://miatatorque.com/spec/dashpot-contact-speed-1992/) 2,500 ± 150 rpm as engine speed slowly decreases

[Engine idle speed — automatic transmission adjustment condition (1992–1993) · NA 1992–1993 (B6, 4AT) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.](https://miatatorque.com/spec/engine-idle-speed-at-1992/) 850 ± 50 rpm (P range)

[Deceleration fuel cut inspection speed (1992–1993) · NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.](https://miatatorque.com/spec/deceleration-fuel-cut-inspection-speed-1992/) Above 1,900 rpm after warm-up, during deceleration

[Fuel tank hose insertion depth (1992–1993) · NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.](https://miatatorque.com/spec/fuel-tank-hose-insertion-depth-1992/) Main fuel, return and evaporation hoses at tank fittings at least 1.0 in (25 mm); filler hose at both pipes at least 1.4 in (35 mm).

[Three-way check valve vacuum test (1992–1993 AT) · NA 1992–1993 (B6, 4AT) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.](https://miatatorque.com/spec/three-way-check-valve-vacuum-test-1992-at/) Airflow at approximately 37 mmHg (1.46 inHg) vacuum at port A and approximately 70 mmHg (2.76 inHg) at port B, with port C plugged.