ABS controller motor harness electrical test (1999–2000)
Without motor command: X to ground 1 Ω maximum and X–AB 0 V with ignition ON. With B+ to B and G grounded: X–AB B+.Without motor command: X to ground 1 Ω maximum and X–AB 0 V with ignition ON. With B+ to B and G grounded: X–AB B+.
Turn ignition OFF before disconnecting or reconnecting the separate ABS control module. Disconnect its connector and attach harness adapter SST49 F066 002 to the harness, then connect the meter to the adapter. Use the factory-lettered adapter terminals; do not infer a pin-face position or probe the controller itself. Perform resistance/continuity checks without applied power, and voltage checks only in the separately stated powered conditions. With ignition still OFF measure X to ground; if resistance exceeds 1 Ω inspect the harness between motor and controller and inspect the motor. For the separate motor-relay harness voltage inspection turn ignition ON and measure X to ground terminal AB: 0 V before the command. Apply B+ to adapter terminal B and ground G, then verify battery voltage at X relative to AB. If incorrect inspect the wiring harness and motor relay. Keep the resistance and powered voltage steps separate. The unit two-pin terminal A and relay component contact letters are different connector systems.
- NB 1999–2000 (BP-4W, ABS) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.
- Verified in: 1999 Mazda MX-5 Miata Workshop Manual
Sources (2)
View 2 source citations
Page 04–13–2 (PDF p. 410) · Printed value & notes
Page 04–13–2 (PDF p. 410)Printed: “Measure the resistance between terminal X of the control module connector and a ground. Resistance 1 Ω max.”Page 04–13–5 /04–13–8 (PDF pp. 413, 416) · Printed value & notes
Page 04–13–5 /04–13–8 (PDF pp. 413, 416)Printed: “Turn the ignition switch to ON. Measure the voltage between terminal X and AB of the ABS control module connector. Voltage 0 V Apply B+ to terminal B, and ground terminal G. Measure the voltage between terminal X and AB of the ABS control module connector. Voltage B+”
Related service specs
- Brake fluid reservoir level during bleeding (1999–2000)
- Brake switch component continuity (1999–2000)
- Brake booster pushrod reference clearance (1999–2000, without ABS)
- Brake fluid level sensor continuity (1999–2000)
- Brake booster vacuum retention, unloaded (1999–2000)
- Brake booster vacuum retention, loaded (1999–2000)
- Brake booster simple function inspection (1999–2000)
- Brake booster hydraulic pressure, unassisted (1999–2000)