Showing specs for all NA & NB Miatas

ABS warning-light voltage scan check (2004–2005)

During the warning-light diagnosis, the scan-tool power-supply voltage item must read above 10 V.During the warning-light diagnosis, the scan-tool power-supply voltage item must read above 10 V.

Factory manualTaken from a Mazda factory workshop manual, with page citation.
Procedure

Use Mazda WDS or an equivalent scan tool at the 16-pin DLC-2 on the left side of the steering column. This reference belongs to step6 of the diagnosis for an ABS or brake warning lamp that remains illuminated more than four seconds after ignition ON, after the preceding DTC and lamp-status checks. Read the power-supply voltage PID named ABS_BOLT on this factory page. It is a scan-tool reading, not permission to probe terminal Z directly and not a replacement for the full fault-specific flowchart. It does not establish a charging-system adjustment or either disputed fault-detection threshold.

Applies to
  • NB 2005 (BP-Z3, ABS)
  • NB 2004–2005 (BP-Z3-TURBO, 6MT, ABS) — 2005 Mazdaspeed applicability is supported by the cited 2005 factory pages; 2004 Mazdaspeed follows the owner-approved 2004–2005 Mazdaspeed carry-over policy. No 2004 Mazdaspeed revision verification is claimed.
  • Verified in: 2005 Mazda MX-5 Miata Workshop Manual (electronic manual capture)

Sources (2)

View 2 source citations
  • 2005 Mazda MX-5 Miata Workshop Manual (electronic manual capture)Tier 1
    Page PID/Data Monitor and Record Procedure (PDF p.1222) · Printed value & notes
    Page PID/Data Monitor and Record Procedure (PDF p.1222)
    Printed: “Connect WDS or equivalent to the vehicle DLC-2 16-pin connector located on the left side of the steering column. Access and monitor PIDs with WDS or equivalent.”
  • 2005 Mazda MX-5 Miata Workshop Manual (electronic manual capture)Tier 1
    Page Warning Light Diagnosis No.2, steps5–6 (PDF pp.1259–1260) · Printed value & notes
    Page Warning Light Diagnosis No.2, steps5–6 (PDF pp.1259–1260)
    Printed: “ABS_BOLT (power supply voltage) Check the voltage for PID/DATA monitor ABS_BOLT item. Specification: above 10 V”