Updated specs are available.
Automatic input sensor resistance (2005)
This spec doesn't apply to the car you selected.
Not yet checked against the factory manual for your car's year. It's verified in the 2005 Mazda MX-5 Miata Workshop Manual (electronic manual capture); later manuals may differ.
560–680 Ω at 68 °F (20 °C)560–680 Ω at 20°C (68°F)
Factory manualTaken from a Mazda factory workshop manual, with page citation.
Procedure
Disconnect input/turbine speed-sensor connector and measure resistance across the two sensor terminals. Remove front exhaust pipe/bracket for access; reinstall afterward. Replace sensor if incorrect. Factory warns that a sensor passing at 20°C can still fail hot; do not rule out temperature-dependent faults from a cold resistance test alone. The 2005 setup is on PDF 1597 and the value continues on PDF 1598.
Applies to
- NB 2005 (BP-Z3, 4AT)
- Verified in: 2005 Mazda MX-5 Miata Workshop Manual (electronic manual capture)
Sources (2)
View 2 source citations
- 2005 Mazda MX-5 Miata Workshop Manual (electronic manual capture)Tier 1
Page Input/Turbine Speed Sensor Inspection (PDF pp.1597–1598) · Printed value & notes
Page Input/Turbine Speed Sensor Inspection (PDF pp.1597–1598)Printed: “Measure the resistance between the terminals of the input/turbine speed sensor. 560—680 ohms (20°C {68°F})” - 2005 Mazda MX-5 Miata Workshop Manual (electronic manual capture)Tier 1
Page Transmission/Transaxle Technical Data (PDF p.1652) · Printed value & notes
Page Transmission/Transaxle Technical Data (PDF p.1652)Printed: “Input/turbine speed sensor (ohm)ATF temperature [20°C {68°F}] 560—680”
Related service specs
- Manual transmission oil replacement interval, U.S.A. (2004–2005)
- Shift solenoid A malfunction — non-turbo 4AT (2005)
- Shift solenoid B malfunction — non-turbo 4AT (2005)
- Both shift solenoids malfunction — non-turbo 4AT (2005)
- Five-speed shift lever mounting sealant (2004–2005)
- Manual speedometer sensor output check (2005)
- Five-speed oil level and plug preparation (2004–2005)
- Automatic line-pressure test (2005)