Automatic key-interlock ground and Park input voltage — non-turbo 4AT (2001–2004)

G-to-body-ground approximately 0 V under any condition. K-to-G: P-position switch ON approximately 0 V; OFF battery voltage.G-to-body-ground approximately 0 V under any condition. K-to-G: P-position switch ON approximately 0 V; OFF battery voltage.

Factory manualTaken from a Mazda factory workshop manual, with page citation.
Procedure

Access the original key-interlock unit behind the front side trim. Keep the harness connected for DC voltage checks. Viewed from the harness wire-entry side with the broad crossed retaining feature above, its connector has eight columns. Upper row left to right: O, unlabelled, K, unlabelled, G, unlabelled, C, A. P is below O at the far left; the other lower positions are unlabelled in the source. B+ means battery voltage. Use G for the negative probe except when measuring G against body ground. The G acceptance is a connected voltage reference, not a printed zero-ohm resistance limit. Switch ON is the closed-contact Park/release-button-released condition; depressing the button in Park opens the switch. Repair the wiring and/or interlock unit if incorrect.

Applies to
  • NB 2003–2004 (BP-Z3, 4AT)
  • NB 2001–2002 (BP-Z3, 4AT) — 2001–2002 applicability follows the owner-approved early-NB2 carry-over policy, with hardware and test setup compared against publication 1719-1U-01G. Its existing owner-accepted 2002 source coverage is unchanged; 2001 is carry-over, not an independently verified year.
  • Verified in: 2003 Mazda MX-5 Miata Workshop Manual (electronic manual capture); 2004 Mazda MX-5 Miata Workshop Manual (electronic manual capture); Mazda MX-5 Workshop Manual, publication 1719-1U-01G (2002 base edition)

Sources (6)

View 6 source citations
  • Mazda MX-5 Workshop Manual, publication 1719-1U-01G (2002 base edition)Tier 1
    Page 05–14–3 (PDF p. 679) · Printed value & notes
    Part no. 1719-1U-01G
    Page 05–14–3 (PDF p. 679)
    Printed: “Terminal / (-) terminal connected to / Condition / Correct measurement value (V) G / Ground / Constant / Approx. 0 K / G / P position switch is on. / Approx. 0 P position switch is off. / B+”
    Visually checked against the original factory page; printed units and component/test context retained. Source edition/market limitations remain as documented; no additional verified years assigned.
  • Mazda MX-5 Workshop Manual, publication 1719-1U-01G (2002 base edition)Tier 1
    Page 05–14–2 (PDF p. 678) · Printed value & notes
    Part no. 1719-1U-01G
    Page 05–14–2 (PDF p. 678)
    Printed: “HARNESS SIDE CONNECTOR (VIEW FROM HARNESS SIDE)”
    Visually checked against the original factory page; printed units and component/test context retained. Source edition/market limitations remain as documented; no additional verified years assigned.
  • 2003 Mazda MX-5 Miata Workshop Manual (electronic manual capture)Tier 1
    Page Key Interlock Unit Inspection (PDF pp. 1471, 1472) · Printed value & notes
    Page Key Interlock Unit Inspection (PDF pp. 1471, 1472)
    Printed: “G Ground Constant Approx. 0 K G P position switch is on. Approx. 0 P position switch is off. B+”
  • 2003 Mazda MX-5 Miata Workshop Manual (electronic manual capture)Tier 1
    Page P Position Switch Inspection (PDF pp. 1489, 1490) · Printed value & notes
    Page P Position Switch Inspection (PDF pp. 1489, 1490)
    Printed: “Position/Range Selector lever release button Continuity P Released Yes Depressed No R, N, D, 2, 1 — No”
  • 2004 Mazda MX-5 Miata Workshop Manual (electronic manual capture)Tier 1
    Page Key Interlock Unit Inspection (PDF pp. 1494, 1495) · Printed value & notes
    Page Key Interlock Unit Inspection (PDF pp. 1494, 1495)
    Printed: “G Ground Under any condition Approx. 0 K G P position switch is on. Approx. 0 P position switch is off. B+”
  • 2004 Mazda MX-5 Miata Workshop Manual (electronic manual capture)Tier 1
    Page P Position Switch Inspection (PDF pp. 1512, 1513) · Printed value & notes
    Page P Position Switch Inspection (PDF pp. 1512, 1513)
    Printed: “Position/Range Selector lever release button Continuity P Released Yes Depressed No R, N, D, 2, 1 — No”