Showing specs for all NA & NB Miatas

Cooling fan motor current draw (2005, non-turbo)

Inspection standard: 5.9 A at 12 V; technical-data range: 4.50–6.49 A at 12 V.Inspection standard: 5.9 A at 12 V; technical-data range: 4.50–6.49 A at 12 V.

Factory manualTaken from a Mazda factory workshop manual, with page citation.
Procedure

Use a fully charged battery, disconnect the cooling-fan motor connector from the vehicle harness, and test the motor with an ammeter in series with the battery supply. In the factory component-connector face view, the latch is uppermost and the right contact is positive; follow that keyed face, not a mirrored harness view. Verify smooth operation at the standard current and replace the motor if the check fails. The dedicated inspection prints the single standard 5.9 A, while technical data prints 4.50–6.49 A; both printed forms are retained without inventing a tolerance around 5.9 A. This is the non-turbo cooling motor, separate from the condenser fan and turbo twin motors.

Applies to
  • NB 2005 (BP-Z3)
  • Verified in: 2005 Mazda MX-5 Miata Workshop Manual (electronic manual capture)

Sources (2)

View 2 source citations
  • 2005 Mazda MX-5 Miata Workshop Manual (electronic manual capture)Tier 1
    Page Cooling Fan Motor Inspection [BP] (PDF p.746) · Printed value & notes
    Page Cooling Fan Motor Inspection [BP] (PDF p.746)
    Printed: “Standard current 5.9 (A) [12V]”
  • 2005 Mazda MX-5 Miata Workshop Manual (electronic manual capture)Tier 1
    Page Engine Technical Data — BP column (PDF p.1047) · Printed value & notes
    Page Engine Technical Data — BP column (PDF p.1047)
    Printed: “Cooling fan motor current [12 V] (A) 4.50—6.49”