Showing specs for all NA & NB Miatas

Cooling fan relay continuity test (1999–2000)

Unpowered: continuity A–B. Battery positive on A and ground on B: continuity C–D.Unpowered: continuity A–B. Battery positive on A and ground on B: continuity C–D.

Factory manualTaken from a Mazda factory workshop manual, with page citation.
Procedure

Disconnect the negative battery cable and remove the cooling fan relay before testing. Use an ohmmeter for the printed continuity checks. Step1 checks the unpowered coil terminals A and B. For step2 apply battery positive toA and ground toB, and verify continuity between switched terminalsC andD. Replace the relay if incorrect. The original relay drawing places B at top, A at bottom, D left and C right in its illustrated view; use those factory terminal labels and do not substitute assumed universal relay numbering or harness-side positions. No numeric coil resistance or fan operating temperature is supplied by this test.

Applies to
  • NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.
  • Verified in: 1999 Mazda MX-5 Miata Workshop Manual

Sources (1)

View 1 source citations
  • Page 01–12–7 (PDF p. 226) · Printed value & notes
    Page 01–12–7 (PDF p. 226)
    Printed: “Disconnect the negative battery cable. Remove the cooling fan relay. Apply battery positive voltage and inspect for continuity between terminals of the cooling fan relay by using an ohmmeter. If not as specified, replace the cooling fan relay.”