Door switch continuity (1999–2000)
Single terminal to metal mounting flange: pressed → no continuity; released → continuity.Single terminal to metal mounting flange: pressed → no continuity; released → continuity.
Disconnect the negative battery cable, remove the mounting screw, withdraw the door switch and disconnect its connector. With the switch isolated, use an ohmmeter between its single electrical terminal and its own metal mounting flange at the screw hole. The circuit must be open while the plunger is pressed and continuous when released. Replace a switch that fails the test. Reinstall in reverse removal order. The factory body-ground drawing identifies the switch mounting flange; there is no multi-contact connector orientation or probe polarity to infer.
- NB 1999–2000 (BP-4W) — 1999 applicability is supported by the cited 1999 factory pages; 2000 follows the owner-approved 1999–2000 NB1 carry-over policy. No 2000 revision verification is claimed.
- Verified in: 1999 Mazda MX-5 Miata Workshop Manual
Sources (1)
View 1 source citations
Page 09–18–13 (PDF p.697) · Printed value & notes
Page 09–18–13 (PDF p.697)Printed: “Switch condition Pressed Released Terminal A Body GND”
Related service specs
- Cruise actuator cable free play (1999–2000)
- Airbag warning-lamp self-test (1999–2000)
- SAS control-module isolation wait (1999–2000)
- Clock-spring centering (1999–2000)
- Airbag post-deployment handling (1999–2000)
- Airbag deployment-tool self-check (1999–2000)
- Seat-belt emergency-locking retractor check (1999–2000)
- Seat-belt automatic-locking mode check (1999–2000)