Showing specs for all NA & NB Miatas

Engine self-diagnosis code pulse timing (1992–1993)

Code-cycle break: 4.0 s; ones-digit buzzer pulses: 0.4 s; tens-digit pulses: 1.2 s; between digit groups: 1.6 s lamp off.Code-cycle break: 4.0 s; ones-digit buzzer pulses: 0.4 s; tens-digit pulses: 1.2 s; between digit groups: 1.6 s lamp off.

Factory manualTaken from a Mazda factory workshop manual, with page citation.
Procedure

Use the factory Self-Diagnosis Checker 49 H018 9A1 and System Selector 49 B019 9A0 at the diagnosis connector and ground. Set checker select switch A, system select 1 and SELF TEST, then ignition ON. Count long pulses for the tens digit and short pulses for the ones digit; the four-second lamp-off interval separates complete code cycles. These are the checker code-reading timings, not fuel injection duration or a sensor response limit. Use the factory fault-specific diagnostic sequence for any code; code reading alone does not authorize component replacement. Before any later battery disconnection obtain the audio anti-theft code and deactivate the original audio anti-theft system.

Applies to
  • NA 1992–1993 (B6) — 1992 applicability is supported by the cited 1992 factory pages; 1993 follows the owner-approved 1992–1993 NA6 carry-over policy. No 1993 revision verification is claimed.
  • Verified in: 1992 Mazda MX-5 Miata Workshop Manual

Sources (1)

View 1 source citations
  • 1992 Mazda MX-5 Miata Workshop ManualTier 1
    Page F–78–F–79 (PDF pp.232–233) · Printed value & notes
    Part no. 1271-10-91G (9999-95-0428-92)
    Page F–78–F–79 (PDF pp.232–233)
    Printed: “The time between malfunction code cycles is 4.0 seconds (the time the lamp is off). The digit in the ones position of the malfunction code represents the number of times the buzzer sounds 0.4 second during one cycle. The digit in the tens position of the malfunction code represents the number of times the buzzer is on 1.2 seconds during one cycle. It should also be noted that the light goes off for 1.6 seconds between the long and short pulses of the buzzer.”