Generator output-current reference test (2005)

At 13.5 V with hot engine and room temperature 68 °F (20 °C): 0–65 A at 1,000 rpm; 0–77 A at 2,000 rpm; current must be greater than zero.At 13.5 V with hot engine and room temperature 20°C (68°F): 0–65 A at 1,000 rpm; 0–77 A at 2,000 rpm; current must be greater than zero.

Factory manualTaken from a Mazda factory workshop manual, with page citation.
Procedure

Reference readings depend on electrical load. Start with charged battery and correct belt tension. With battery negative disconnected, install a circuit tester rated at least 120 A in series between generator B and its wiring harness, then reconnect negative cable. For the functional load check, run at 2,000–2,500 rpm and switch on headlights, blower and rear defroster; current must increase. The separate 1,000/2,000 rpm table is the factory reference, not a fixed minimum rated output.

Applies to
  • NB 2005 (BP-Z3)
  • Verified in: 2005 Mazda MX-5 Miata Workshop Manual (electronic manual capture)

Sources (1)

View 1 source citations
  • 2005 Mazda MX-5 Miata Workshop Manual (electronic manual capture)Tier 1
    Page Generator Inspection — current (PDF pp.898–899) · Printed value & notes
    Page Generator Inspection — current (PDF pp.898–899)
    Printed: “Connect a circuit tester, capable of reading 120 A or more, between generator terminal B and the wiring harness. Standard current (Reference) Room temperature: 20 °C {68 °F} Voltage: 13.5 V Engine hot Engine speed (rpm) Terminal B current (A) 1,000 0 *—65 2,000 0 *—77 *: Lower limit of current must be more than 0 A.”